Measurements of mandibular canal region obtained by cone-beam computed tomography: a cadaveric study

被引:75
作者
Kamburoglu, Kivanc [1 ,2 ]
Kilic, Cenk [3 ]
Oezen, Tuncer [2 ]
Yueksel, Selcen Pehlivan [4 ]
机构
[1] Ankara Univ, Fac Dent, Dept Oral Diag & Radiol, TR-06100 Ankara, Turkey
[2] Gulhane Mil Med Acad, Dent Sci Ctr, Dept Oral Diag & Radiol, Ankara, Turkey
[3] Gulhane Mil Med Acad, Fac Med, Dept Anat, Ankara, Turkey
[4] Ankara Univ, Fac Med, Dept Biostat, TR-06100 Ankara, Turkey
来源
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY | 2009年 / 107卷 / 02期
关键词
IMPLANT PLACEMENT; ACCURACY; CT; LOCALIZATION; POSITION; ALVEOLAR; IMAGES;
D O I
10.1016/j.tripleo.2008.10.012
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective. The objective of this study was to assess the accuracy and reproducibility of cone-beam CT measurements of specific distances around the mandibular canal by comparing them to direct digital caliper measurements. Methods. Six formalin-fixed hemimandible specimens were examined using the ILUMA cone-beam CT system. Images were obtained at 120 kVp, 3.8 mA, and a voxel size of 0.2 mm, with an exposure time of 40 seconds. Specimens were cut into sections at 7 locations using a Lindemann burr, and a digital caliper was used to measure the following distances on both the anterior and posterior sides of each section: Mandibular Width (W); Mandibular Length (L); Upper Distance (UD); Lower Distance (LD); Buccal Distance (BD); and Lingual Distance (LID). The same distances were measured on the corresponding cross-sectional cone-beam CT images using the built-in measurement software. All caliper and cone-beam CT measurements were made by 2 independent trained observers and were repeated after an interval of 1 week. The Bland/Altman method was used to calculate intra- and inter-rater reliability. Intra-class correlation coefficients (ICCs) from 2-way random effects model were calculated. Agreements between cone-beam CT and direct digital caliper were calculated by ICC for 6 distances and 2 observers. Results. Intraobserver and interobserver measurements for all distances showed high agreement. ICCs for intraobserver agreement ranged from 0.86 to 0.97 for cone-beam CT measurements and from 0.98 to 0.99 for digital caliper measurements. ICCs between observers ranged from 0.84 to 0.97 for the cone-beam CT measurements and from 0.78 to 0.97 for the digital caliper measurements. ICCs for cone-beam CT and direct digital caliper ranged from 0.61 to 0.93 for the first observer and from 0.40 to 0.95 for the second observer. Conclusion. Accuracy of cone-beam CT measurements of various distances surrounding the mandibular canal was comparable to that of digital caliper measurements. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2009; 107: e34-e42)
引用
收藏
页码:E34 / E42
页数:9
相关论文
共 25 条
  • [11] A new volumetric CT machine for dental imaging based on the cone-beam technique: preliminary results
    Mozzo, P
    Procacci, C
    Tacconi, A
    Martini, PT
    Andreis, IAB
    [J]. EUROPEAN RADIOLOGY, 1998, 8 (09) : 1558 - 1564
  • [12] Preoperative application of limited cone beam computerized tomography as an assessment tool before minor oral surgery
    Nakagawa, Y
    Kobayashi, K
    Ishii, H
    Mishima, A
    Ishii, H
    Asada, K
    Ishibashi, K
    [J]. INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2002, 31 (03) : 322 - 326
  • [13] Nasel CJO, 1999, AM J NEURORADIOL, V20, P1221
  • [14] Comparison of cone-beam volumetric imaging and combined plain radiographs for localization of the mandibular canal before removal of impacted lower third molars
    Neugebauer, Joerg
    Shirani, Rusbeh
    Mischkowski, Robert A.
    Ritter, Lutz
    Scheer, Martin
    Keeve, Erwin
    Zoeller, Joachim E.
    [J]. ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2008, 105 (05): : 633 - 642
  • [15] Reliability of implant placement after virtual planning of implant positions using cone beam CT data and surgical (guide) templates
    Nickenig, Hans-Joachim
    Eitner, Stephan
    [J]. JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2007, 35 (4-5) : 207 - 211
  • [16] Reproducibility and accuracy of measuring unerupted teeth using limited cone beam X-ray CT
    Sakabe, J.
    Kuroki, Y.
    Fujimaki, S.
    Nakajima, I.
    Honda, K.
    [J]. DENTOMAXILLOFACIAL RADIOLOGY, 2007, 36 (01) : 2 - 6
  • [17] Scarfe WC, 2006, J CAN DENT ASSOC, V72, P75
  • [18] Localisation of the mandibular canal using conventional spiral tomography: a human cadaver study
    Serhal, CB
    van Steenberghe, D
    Quirynen, M
    Jacobs, R
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2001, 12 (03) : 230 - 236
  • [19] Comparison of cone beam computed tomography imaging with physical measures
    Stratemann, S. A.
    Huang, J. C.
    Maki, K.
    Miller, A. J.
    Hatcher, D. C.
    [J]. DENTOMAXILLOFACIAL RADIOLOGY, 2008, 37 (02) : 80 - 93
  • [20] Sukovic P, 2003, Orthod Craniofac Res, V6 Suppl 1, P31, DOI 10.1034/j.1600-0544.2003.259.x