Measurements of mandibular canal region obtained by cone-beam computed tomography: a cadaveric study

被引:76
作者
Kamburoglu, Kivanc [1 ,2 ]
Kilic, Cenk [3 ]
Oezen, Tuncer [2 ]
Yueksel, Selcen Pehlivan [4 ]
机构
[1] Ankara Univ, Fac Dent, Dept Oral Diag & Radiol, TR-06100 Ankara, Turkey
[2] Gulhane Mil Med Acad, Dent Sci Ctr, Dept Oral Diag & Radiol, Ankara, Turkey
[3] Gulhane Mil Med Acad, Fac Med, Dept Anat, Ankara, Turkey
[4] Ankara Univ, Fac Med, Dept Biostat, TR-06100 Ankara, Turkey
来源
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY | 2009年 / 107卷 / 02期
关键词
IMPLANT PLACEMENT; ACCURACY; CT; LOCALIZATION; POSITION; ALVEOLAR; IMAGES;
D O I
10.1016/j.tripleo.2008.10.012
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective. The objective of this study was to assess the accuracy and reproducibility of cone-beam CT measurements of specific distances around the mandibular canal by comparing them to direct digital caliper measurements. Methods. Six formalin-fixed hemimandible specimens were examined using the ILUMA cone-beam CT system. Images were obtained at 120 kVp, 3.8 mA, and a voxel size of 0.2 mm, with an exposure time of 40 seconds. Specimens were cut into sections at 7 locations using a Lindemann burr, and a digital caliper was used to measure the following distances on both the anterior and posterior sides of each section: Mandibular Width (W); Mandibular Length (L); Upper Distance (UD); Lower Distance (LD); Buccal Distance (BD); and Lingual Distance (LID). The same distances were measured on the corresponding cross-sectional cone-beam CT images using the built-in measurement software. All caliper and cone-beam CT measurements were made by 2 independent trained observers and were repeated after an interval of 1 week. The Bland/Altman method was used to calculate intra- and inter-rater reliability. Intra-class correlation coefficients (ICCs) from 2-way random effects model were calculated. Agreements between cone-beam CT and direct digital caliper were calculated by ICC for 6 distances and 2 observers. Results. Intraobserver and interobserver measurements for all distances showed high agreement. ICCs for intraobserver agreement ranged from 0.86 to 0.97 for cone-beam CT measurements and from 0.98 to 0.99 for digital caliper measurements. ICCs between observers ranged from 0.84 to 0.97 for the cone-beam CT measurements and from 0.78 to 0.97 for the digital caliper measurements. ICCs for cone-beam CT and direct digital caliper ranged from 0.61 to 0.93 for the first observer and from 0.40 to 0.95 for the second observer. Conclusion. Accuracy of cone-beam CT measurements of various distances surrounding the mandibular canal was comparable to that of digital caliper measurements. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2009; 107: e34-e42)
引用
收藏
页码:E34 / E42
页数:9
相关论文
共 25 条
[1]  
ABRAHAMS JJ, 1996, HEAD NECK IMAGING, P350
[2]  
ADELL R, 1992, TISSUE INTEGRATED PR, P215
[3]   ANATOMICAL RELATIONSHIP OF THE MANDIBULAR CANAL TO ITS SURROUNDING STRUCTURES IN MATURE MANDIBLES [J].
DENIO, D ;
TORABINEJAD, M ;
BAKLAND, LK .
JOURNAL OF ENDODONTICS, 1992, 18 (04) :161-165
[4]   HIGH-RESOLUTION COMPUTED-TOMOGRAPHY OF THE INFERIOR ALVEOLAR AND LINGUAL NERVES [J].
FEIFEL, H ;
RIEDIGER, D ;
GUSTORFAECKERLE, R .
NEURORADIOLOGY, 1994, 36 (03) :236-238
[5]   Accuracy of cone beam computed tomography in determining the location of the genial tubercle [J].
Hueman, Elizabeth M. ;
Noujeim, Marcel E. ;
Langlais, Robert P. ;
Prihoda, Thomas J. ;
Miller, Frank R. .
OTOLARYNGOLOGY-HEAD AND NECK SURGERY, 2007, 137 (01) :115-118
[6]  
Kobayashi K, 2004, INT J ORAL MAX IMPL, V19, P228
[7]   Analysis of the accuracy of linear measurements obtained by cone beam computed tomography (CBCT-NewTom) [J].
Lascala, C ;
Panella, J ;
Marques, MM .
DENTOMAXILLOFACIAL RADIOLOGY, 2004, 33 (05) :291-294
[8]   Localization of impacted maxillary canines and observation of adjacent incisor resorption with cone-beam computed tomography [J].
Liu, Deng-gao ;
Zhang, Wan-lin ;
Zhang, Zu-yan ;
Wu, Yun-tang ;
Ma, Xu-chen .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2008, 105 (01) :91-98
[9]   Comparative localized linear accuracy of small-field cone-beam CT and multislice CT for alveolar bone measurements [J].
Loubele, M. ;
Van Assche, N. ;
Carpentier, K. ;
Maes, F. ;
Jacobs, R. ;
van Steenberghe, D. ;
Suetens, P. .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2008, 105 (04) :512-518
[10]   Accuracy of measurements of mandibular anatomy in cone beam computed tomography images [J].
Ludlow, John B. ;
Laster, William Stewart ;
See, Meit ;
Bailey, L'Tanya J. ;
Garland Hershey, H. .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2007, 103 (04) :534-542