Measurements of mandibular canal region obtained by cone-beam computed tomography: a cadaveric study

被引:75
作者
Kamburoglu, Kivanc [1 ,2 ]
Kilic, Cenk [3 ]
Oezen, Tuncer [2 ]
Yueksel, Selcen Pehlivan [4 ]
机构
[1] Ankara Univ, Fac Dent, Dept Oral Diag & Radiol, TR-06100 Ankara, Turkey
[2] Gulhane Mil Med Acad, Dent Sci Ctr, Dept Oral Diag & Radiol, Ankara, Turkey
[3] Gulhane Mil Med Acad, Fac Med, Dept Anat, Ankara, Turkey
[4] Ankara Univ, Fac Med, Dept Biostat, TR-06100 Ankara, Turkey
来源
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY | 2009年 / 107卷 / 02期
关键词
IMPLANT PLACEMENT; ACCURACY; CT; LOCALIZATION; POSITION; ALVEOLAR; IMAGES;
D O I
10.1016/j.tripleo.2008.10.012
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective. The objective of this study was to assess the accuracy and reproducibility of cone-beam CT measurements of specific distances around the mandibular canal by comparing them to direct digital caliper measurements. Methods. Six formalin-fixed hemimandible specimens were examined using the ILUMA cone-beam CT system. Images were obtained at 120 kVp, 3.8 mA, and a voxel size of 0.2 mm, with an exposure time of 40 seconds. Specimens were cut into sections at 7 locations using a Lindemann burr, and a digital caliper was used to measure the following distances on both the anterior and posterior sides of each section: Mandibular Width (W); Mandibular Length (L); Upper Distance (UD); Lower Distance (LD); Buccal Distance (BD); and Lingual Distance (LID). The same distances were measured on the corresponding cross-sectional cone-beam CT images using the built-in measurement software. All caliper and cone-beam CT measurements were made by 2 independent trained observers and were repeated after an interval of 1 week. The Bland/Altman method was used to calculate intra- and inter-rater reliability. Intra-class correlation coefficients (ICCs) from 2-way random effects model were calculated. Agreements between cone-beam CT and direct digital caliper were calculated by ICC for 6 distances and 2 observers. Results. Intraobserver and interobserver measurements for all distances showed high agreement. ICCs for intraobserver agreement ranged from 0.86 to 0.97 for cone-beam CT measurements and from 0.98 to 0.99 for digital caliper measurements. ICCs between observers ranged from 0.84 to 0.97 for the cone-beam CT measurements and from 0.78 to 0.97 for the digital caliper measurements. ICCs for cone-beam CT and direct digital caliper ranged from 0.61 to 0.93 for the first observer and from 0.40 to 0.95 for the second observer. Conclusion. Accuracy of cone-beam CT measurements of various distances surrounding the mandibular canal was comparable to that of digital caliper measurements. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2009; 107: e34-e42)
引用
收藏
页码:E34 / E42
页数:9
相关论文
共 25 条
  • [1] ABRAHAMS JJ, 1996, HEAD NECK IMAGING, P350
  • [2] ADELL R, 1992, TISSUE INTEGRATED PR, P215
  • [3] ANATOMICAL RELATIONSHIP OF THE MANDIBULAR CANAL TO ITS SURROUNDING STRUCTURES IN MATURE MANDIBLES
    DENIO, D
    TORABINEJAD, M
    BAKLAND, LK
    [J]. JOURNAL OF ENDODONTICS, 1992, 18 (04) : 161 - 165
  • [4] HIGH-RESOLUTION COMPUTED-TOMOGRAPHY OF THE INFERIOR ALVEOLAR AND LINGUAL NERVES
    FEIFEL, H
    RIEDIGER, D
    GUSTORFAECKERLE, R
    [J]. NEURORADIOLOGY, 1994, 36 (03) : 236 - 238
  • [5] Accuracy of cone beam computed tomography in determining the location of the genial tubercle
    Hueman, Elizabeth M.
    Noujeim, Marcel E.
    Langlais, Robert P.
    Prihoda, Thomas J.
    Miller, Frank R.
    [J]. OTOLARYNGOLOGY-HEAD AND NECK SURGERY, 2007, 137 (01) : 115 - 118
  • [6] Kobayashi K, 2004, INT J ORAL MAX IMPL, V19, P228
  • [7] Analysis of the accuracy of linear measurements obtained by cone beam computed tomography (CBCT-NewTom)
    Lascala, C
    Panella, J
    Marques, MM
    [J]. DENTOMAXILLOFACIAL RADIOLOGY, 2004, 33 (05) : 291 - 294
  • [8] Localization of impacted maxillary canines and observation of adjacent incisor resorption with cone-beam computed tomography
    Liu, Deng-gao
    Zhang, Wan-lin
    Zhang, Zu-yan
    Wu, Yun-tang
    Ma, Xu-chen
    [J]. ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2008, 105 (01): : 91 - 98
  • [9] Comparative localized linear accuracy of small-field cone-beam CT and multislice CT for alveolar bone measurements
    Loubele, M.
    Van Assche, N.
    Carpentier, K.
    Maes, F.
    Jacobs, R.
    van Steenberghe, D.
    Suetens, P.
    [J]. ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2008, 105 (04): : 512 - 518
  • [10] Accuracy of measurements of mandibular anatomy in cone beam computed tomography images
    Ludlow, John B.
    Laster, William Stewart
    See, Meit
    Bailey, L'Tanya J.
    Garland Hershey, H.
    [J]. ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2007, 103 (04): : 534 - 542