Diagnostic accuracy of a novel tuberculosis point-of-care urine lipoarabinomannan assay for people living with HIV: A meta-analysis of individual in- and outpatient data

被引:54
|
作者
Broger, Tobias [1 ]
Nicol, Mark P. [2 ,3 ,4 ]
Szekely, Rita [1 ]
Bjerrum, Stephanie [5 ,6 ]
Sossen, Bianca [7 ,8 ]
Schutz, Charlotte [7 ,8 ]
Opintan, Japheth A. [9 ]
Johansen, Isik S. [5 ,6 ]
Mitarai, Satoshi [10 ]
Chikamatsu, Kinuyo [10 ]
Kerkhoff, Andrew D. [11 ,12 ]
Mace, Aurelien [1 ]
Ongarello, Stefano [1 ]
Meintjes, Graeme [7 ,8 ]
Denkinger, Claudia M. [1 ,13 ]
Schumacher, Samuel G. [1 ]
机构
[1] FIND, Geneva, Switzerland
[2] Univ Western Australia, Sch Biomed Sci, Div Infect & Immun, Perth, WA, Australia
[3] Univ Cape Town, Div Med Microbiol, Cape Town, South Africa
[4] Natl Hlth Lab Serv, Cape Town, South Africa
[5] Odense Univ Hosp, Dept Infect Dis, Mycobacterial Res Ctr Southern Denmark, Odense, Denmark
[6] Univ Southern Denmark, Infect Dis Unit, Dept Clin Res, Odense, Denmark
[7] Univ Cape Town, Dept Med, Fac Hlth Sci, Cape Town, South Africa
[8] Univ Cape Town, Inst Infect Dis & Mol Med, Wellcome Ctr Infect Dis Res Africa, Cape Town, South Africa
[9] Univ Ghana, Coll Hlth Sci, Sch Biomed & Allied Sci, Dept Med Microbiol, Accra, Ghana
[10] Japan AntiTB Assoc, Res Inst TB, Dept Mycobacterium Reference & Res, Tokyo, Japan
[11] Univ Calif San Francisco, Zuckerberg San Francisco Gen Hosp, Div HIV Infect Dis & Global Med, San Francisco, CA 94143 USA
[12] Univ Calif San Francisco, Dept Med, Ctr Trauma, San Francisco, CA 94143 USA
[13] Heidelberg Univ Hosp, Div Trop Med, Ctr Infect Dis, Heidelberg, Germany
基金
英国医学研究理事会; 比尔及梅琳达.盖茨基金会; 新加坡国家研究基金会; 英国惠康基金;
关键词
DETERMINE TB-LAM; UNDERESTIMATION; YIELD;
D O I
10.1371/journal.pmed.1003113
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Tuberculosis (TB) is the most common cause of death in people living with HIV (PLHIV), yet TB often goes undiagnosed since many patients are not able to produce a sputum specimen, and traditional diagnostics are costly or unavailable. A novel, rapid lateral flow assay, Fujifilm SILVAMP TB LAM (SILVAMP-LAM), detects the presence of TB lipoarabinomannan (LAM) in urine, and is substantially more sensitive for diagnosing TB in PLHIV than an earlier LAM assay (Alere Determine TB LAM lateral flow assay [LF-LAM]). Here, we present an individual participant data meta-analysis of the diagnostic accuracy of SILVAMP-LAM in adult PLHIV, including both published and unpublished data. Methods and findings Adult PLHIV (>= 18 years) were assessed in 5 prospective cohort studies in South Africa (3 cohorts), Vietnam, and Ghana, carried out during 2012 to 2017. Of the 1,595 PLHIV who met eligibility criteria, the majority (61%) were inpatients, median age was 37 years (IQR 30-43), 43% had a CD4 count < 100 cells/mu l, and 35% were receiving antiretroviral therapy. Most participants (94%) had a positive WHO symptom screen for TB on enrollment, and 45% were diagnosed with microbiologically confirmed TB, using mycobacterial culture or Xpert MTB/RIF testing of sputum, urine, or blood. Previously published data from inpatients were combined with unpublished data from outpatients. Biobanked urine samples were tested, using blinded double reading, with SILVAMP-LAM and LF-LAM. Applying a microbiological reference standard for assessment of sensitivity, the overall sensitivity for TB detection was 70.7% (95% CI 59.0%-80.8%) for SILVAMP-LAM compared to 34.9% (95% CI 19.5%-50.9%) for LF-LAM. Using a composite reference standard (which included patients with both microbiologically confirmed as well as clinically diagnosed TB), SILVAMP-LAM sensitivity was 65.8% (95% CI 55.9%-74.6%), and that of LF-LAM 31.4% (95% CI 19.1%-43.7%). In patients with CD4 count. 100 cells/mu l, SILVAMP-LAM sensitivity was 87.1% (95% CI 79.3%-93.6%), compared to 56.0% (95% CI 43.9%-64.9%) for LF-LAM. In patients with CD4 count 101-200 cells/mu l, SILVAMP-LAM sensitivity was 62.7% (95% CI 52.4%-71.9%), compared to 25.3% (95% CI 15.8%-34.9%) for LF-LAM. In those with CD4 count > 200 cells/mu l, SILVAMP-LAM sensitivity was 43.9% (95% CI 34.3%-53.9%), compared to 10.9% (95% CI 5.2%-18.4%) for LF-LAM. Using a microbiological reference standard, the specificity of SILVAMP-LAM was 90.9% (95% CI 87.2%-93.7%), and that of LF-LAM 95.3% (95% CI 92.2%-97.7%). Limitations of this study include the use of biobanked, rather than fresh urine samples, and testing by skilled laboratory technicians in research laboratories, rather than at the point of care. Conclusions In this study, we found that SILVAMP-LAM identified a substantially higher proportion of TB patients in PLHIV than LF-LAM. The sensitivity of SILVAMP-LAM was highest in patients with CD4 count. 100 cells/mu l. Further work is needed to demonstrate accuracy when implemented as a point-of-care test.
引用
收藏
页数:16
相关论文
共 50 条
  • [41] Point-of-care tests for urinary tract infections: protocol for a systematic review and meta-analysis of diagnostic test accuracy
    Navarro, David Fraile
    Sullivan, Frank
    Azcoaga-Lorenzo, Amaya
    Santiago, Virginia Hernandez
    BMJ OPEN, 2020, 10 (06): : e033424
  • [42] Diagnostic accuracy of point-of-care natriuretic peptide testing for chronic heart failure in ambulatory care: systematic review and meta-analysis
    Taylor, Kathryn S.
    Verbakel, Jan Y.
    Feakins, Benjamin G.
    Price, Christopher P.
    Perera, Rafael
    Bankhead, Clare
    Pluddemann, Annette
    BMJ-BRITISH MEDICAL JOURNAL, 2018, 361
  • [43] Vomiting, Pyloric Mass, and Point-of-Care Ultrasound: Diagnostic Test Accuracy for Hypertrophic Pyloric Stenosis-A Meta-Analysis
    Hom, Jeffrey
    Lam, Samuel H. F.
    Delaney, Kristen M.
    Koos, Jessica A.
    Kunkov, Sergey
    JOURNAL OF EMERGENCY MEDICINE, 2023, 65 (05): : E427 - E431
  • [44] Systematic Review and Meta-Analysis of Diagnostic Test Accuracy Studies Evaluating Point-of-Care Tests of Coagulopathy in Cardiac Surgery
    Wozniak, Marcin J.
    Abbasciano, Riccardo
    Monaghan, Alexandra
    Lai, Florence Y.
    Corazzari, Claudio
    Tutino, Cassandra
    Kumar, Tracy
    Whiting, Penny
    Murphy, Gavin J.
    TRANSFUSION MEDICINE REVIEWS, 2021, 35 (01) : 7 - 15
  • [45] Accuracy of Rapid Point-of-Care Diagnostic Tests for Hepatitis B Surface Antigen-A Systematic Review and Meta-analysis
    Khuroo, Mehnaaz S.
    Khuroo, Naira S.
    Khuroo, Mohammad S.
    JOURNAL OF CLINICAL AND EXPERIMENTAL HEPATOLOGY, 2014, 4 (03) : 226 - 240
  • [46] Point-Of-Care C-Reactive Protein-Based Tuberculosis Screening For People Living With Hiv: Diagnostic Accuracy And Implications For Isoniazid Preventive Therapy And Intensified Case-Finding
    Yoon, C.
    Davis, J. L.
    Semitala, F. C.
    Katende, J.
    Byanyima, P.
    Ayakaka, I.
    Huang, L.
    Cattamanchi, A.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2014, 189
  • [47] Development of a Standardized Screening Rule for Tuberculosis in People Living with HIV in Resource-Constrained Settings: Individual Participant Data Meta-analysis of Observational Studies
    Getahun, Haileyesus
    Kittikraisak, Wanitchaya
    Heilig, Charles M.
    Corbett, Elizabeth L.
    Ayles, Helen
    Cain, Kevin P.
    Grant, Alison D.
    Churchyard, Gavin J.
    Kimerling, Michael
    Shah, Sarita
    Lawn, Stephen D.
    Wood, Robin
    Maartens, Gary
    Granich, Reuben
    Date, Anand A.
    Varma, Jay K.
    PLOS MEDICINE, 2011, 8 (01):
  • [48] Diagnostic accuracy of WHO screening criteria to guide lateral-flow lipoarabinomannan testing among HIV-positive inpatients: A systematic review and individual participant data meta-analysis
    Dhana, Ashar
    Hamada, Yohhei
    Kengne, Andre P.
    Kerkhoff, Andrew D.
    Broger, Tobias
    Denkinger, Claudia M.
    Rangaka, Molebogeng X.
    Gupta-Wright, Ankur
    Fielding, Katherine
    Wood, Robin
    Huerga, Helena
    Ruecker, Sekai Chenai Mathabire
    Bjerrum, Stephanie
    Johansen, Isik S.
    Thit, Swe Swe
    Kyi, Mar Mar
    Hanson, Josh
    Barr, David A.
    Meintjes, Graeme
    Maartens, Gary
    JOURNAL OF INFECTION, 2022, 85 (01) : 40 - 48
  • [49] Systematic Review and Meta-Analysis of the Diagnostic Accuracy of Mobile-Linked Point-of-Care Diagnostics in Sub-Saharan Africa
    Osei, Ernest
    Nkambule, Sphamandla Josias
    Vezi, Portia Nelisiwe
    Mashamba-Thompson, Tivani P.
    DIAGNOSTICS, 2021, 11 (06)
  • [50] Diagnostic accuracy of a point-of-care urine test for tuberculosis screening among newly-diagnosed hiv-infected adults: a prospective, clinic-based study
    Drain, Paul K.
    Losina, Elena
    Coleman, Sharon M.
    Giddy, Janet
    Ross, Douglas
    Katz, Jeffrey N.
    Walensky, Rochelle P.
    Freedberg, Kenneth A.
    Bassett, Ingrid V.
    BMC INFECTIOUS DISEASES, 2014, 14