A modified magnetic resonance wireless power transfer system for capsule endoscopy

被引:2
作者
Miarnaeimi, Masoumeh [1 ]
Ghalibafan, Javad [1 ]
Hashemi, Seyed Mohammad [2 ]
机构
[1] Shahrood Univ Technol, Fac Elect Engn & Robot, Shahrood 3619995161, Iran
[2] Shahid Rajaee Teacher Training Univ, Dept Elect Engn, Tehran, Iran
关键词
Capsule endoscopy; printed WPT system; SAR; wireless power transfer; EFFICIENCY; TRANSMISSION; DESIGN; BRAIN; SAR;
D O I
10.1080/15368378.2019.1591440
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
Background: The current study presents a fully planar wireless power transfer (WPT) scheme with the aim of providing enough power for capsule endoscopy performance. The method's implementation on patients is more convenient than that of the previous conventional WPT plans in which a cylindrical wire coil is placed around the patient's body. In addition to this, while using the present printed power receiver structure, the capsule's internal space of opens up for other components such as the image sensors and data transmitting components. To improve the efficiency, a two-layer printed coil has been used as the transmitter, a two-layer printed coil as the receiver and a power coil on the transmitter side excited at 13.56MHz.Results: Applying this method, the efficiency has increased to more than 2% for the proposed structure. Moreover, the effect of the body tissue on power efficiency has been simulated and measured and the maximum specific absorption rate (SAR) value considered for the desired system. Conclusions: The obtained results indicate that the proposed system meets the medical standards requirements.
引用
收藏
页码:158 / 167
页数:10
相关论文
共 27 条
[1]  
Ahlbom A, 1998, HEALTH PHYS, V74, P494
[2]   Optimal Design of Wireless Power Transmission Links for Millimeter-Sized Biomedical Implants [J].
Ahn, Dukju ;
Ghovanloo, Maysam .
IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS, 2016, 10 (01) :125-137
[3]   Evaluation of Skin and Subcutaneous Adipose Tissue Thickness for Optimal Insulin Injection [J].
Akkus, Oktay ;
Oguz, Aytekin ;
Uzunlulu, Mehmet ;
Kizilgul, Muhammed .
JOURNAL OF DIABETES & METABOLISM, 2012, 3 (08)
[4]   Computed tomography scan measurement of abdominal wall thickness for application of near-infrared spectroscopy probes to monitor regional oxygen saturation index of gastrointestinal and renal circulations in children [J].
Balaguru, Duraisamy ;
Bhalala, Utpal ;
Haghighi, Mohammad ;
Norton, Karen .
PEDIATRIC CRITICAL CARE MEDICINE, 2011, 12 (03) :E145-E148
[5]   An Improved Wearable Resonant Wireless Power Transfer System for Biomedical Capsule Endoscope [J].
Basar, Md. Rubel ;
Ahmad, Mohd Yazed ;
Cho, Jongman ;
Ibrahim, Fatimah .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2018, 65 (10) :7772-7781
[6]   Application of Wireless Power Transmission Systems in Wireless Capsule Endoscopy: An Overview [J].
Basar, Md Rubel ;
Ahmad, Mohd Yazed ;
Cho, Jongman ;
Ibrahim, Fatimah .
SENSORS, 2014, 14 (06) :10929-10951
[7]  
Dubey S, 2016, IEEE TOPIC CONF BIOM, P15
[8]   In Vivo Characterization of a Wireless Telemetry Module for a Capsule Endoscopy System Utilizing a Conformal Antenna [J].
Faerber, Julia ;
Cummins, Gerard ;
Pavuluri, Sumanth Kumar ;
Record, Paul ;
Rodriguez, Adrian R. Ayastuy ;
Lay, Holly S. ;
McPhillips, Rachael ;
Cox, Benjamin F. ;
Connor, Ciaran ;
Gregson, Rachael ;
Clutton, Richard Eddie ;
Khan, Sadeque Reza ;
Cochran, Sandy ;
Desmulliez, Marc P. Y. .
IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS, 2018, 12 (01) :95-105
[9]   Wearable slot antenna at 2.45GHz for off-body radiation: Analysis of efficiency, frequency shift, and body absorption [J].
Fernandez, Marta ;
Espinosa, Hugo G. ;
Thiel, David V. ;
Arrinda, Amaia .
BIOELECTROMAGNETICS, 2018, 39 (01) :25-34
[10]   SAR investigations on the exposure compliance of wearable wireless devices using infrared thermography [J].
Karthik, Varshini ;
Rao, T. Rama .
BIOELECTROMAGNETICS, 2018, 39 (06) :451-459