Atmospheric-pressure dielectric-barrier discharge as a radiation source for optical emission spectrometry

被引:136
作者
Yu, Yongliang [1 ]
Du, Zhuo [1 ]
Chen, Mingli [1 ]
Wang, Jianhua [1 ]
机构
[1] NE Univ, Res Ctr Analyt Sci, Shenyang 110004, Peoples R China
关键词
cold microplasma; dielectric-barrier discharge; mercury; optical emission spectrometry;
D O I
10.1002/anie.200802681
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Honey, I shrunk the spectrometer: The use of atmospheric-pressure dielectric-barrier discharge (DBD) as a radiation source for atomic optical emission spectrometry (OES) allowed the construction of a miniaturized DBD-OES system. A microsequential injection configuration (the picture shows the DBD unit and its cross-sectional configuration, HV=discharge power) provides favorable analytical performance for the system, as demonstrated for the determination of mercury. (Figure Presented). © 2008 Wiley-VCH Verlag GmbH & Co. KGaA.
引用
收藏
页码:7909 / 7912
页数:4
相关论文
共 25 条
[1]   Influence of the optical depth on spectral line emission from laser-induced plasmas [J].
Aragón, C ;
Bengoechea, J ;
Aguilera, JA .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2001, 56 (06) :619-628
[2]   Microsecond pulsed glow discharge optical emission spectrometry - investigation of temporal emission characteristics [J].
Bengtson, A ;
Yang, CL ;
Harrison, WW .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2000, 15 (09) :1279-1284
[3]   A dc microplasma on a chip employed as an optical emission detector for gas chromatography [J].
Eijkel, JCT ;
Stoeri, H ;
Manz, A .
ANALYTICAL CHEMISTRY, 2000, 72 (11) :2547-2552
[4]   Radio frequency glow discharge-optical emission spectrometry for direct quantitative analysis of glass [J].
Fernández, B ;
Bordel, N ;
Pereiro, R ;
Sanz-Medel, A .
ANALYTICAL CHEMISTRY, 2004, 76 (04) :1039-1044
[5]   Microplasmas, an emerging field of low-temperature plasma science and technology [J].
Foest, R ;
Schmidt, M ;
Becker, K .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2006, 248 (03) :87-102
[6]   Multivariate study in chemical vapor generation for simultaneous determination of arsenic, antimony, bismuth, germanium, tin, selenium, tellurium and mercury by inductively coupled plasma optical emission spectrometry [J].
Grotti, M ;
Lagomarsino, C ;
Frache, R .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2005, 20 (12) :1365-1373
[7]   Determination of organic compounds by gas chromatography using a new capacitively coupled microplasma detector [J].
Guchardi, R ;
Hauser, PC .
ANALYST, 2004, 129 (04) :347-351
[8]   Mesoporous titanium dioxide as a novel solid-phase extraction material for flow injection micro-column preconcentration on-line coupled with ICP-OES determination of trace metals in environmental samples [J].
Huang, Chaozhang ;
Jiang, Zucheng ;
Hu, Bin .
TALANTA, 2007, 73 (02) :274-281
[9]   Mercury speciation by HPLC-cold-vapour radiofrequency glow-discharge optical-emission spectrometry with on-line microwave oxidation [J].
Martínez, R ;
Pereiro, R ;
Sanz-Medel, A ;
Bordel, N .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2001, 371 (06) :746-752
[10]   Evaluation of various nebulizers for use in microwave induced plasma optical emission spectrometry [J].
Matusiewicz, Henryk ;
Slachcinski, Mariusz ;
Hidalgo, Montserrat ;
Canals, Antonio .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2007, 22 (09) :1174-1178