Determination of temporal reproducibility and variability of cancer biomarkers in serum and EDTA plasma samples using a proximity extension assay

被引:5
作者
Christensen, Troels D. [1 ]
Maag, Emil [2 ]
Madsen, Kasper [1 ]
Lindgaard, Sidsel Christy [1 ]
Nielsen, Dorte L. [1 ,3 ]
Johansen, Julia S. [1 ,3 ,4 ]
机构
[1] Copenhagen Univ Hosp Herlev & Gentofte, Dept Oncol, Borgmester Ib Juuls Vej 1, DK-2730 Herlev, Denmark
[2] BioXpedia, Aarhus, Denmark
[3] Univ Copenhagen, Fac Hlth & Med Sci, Dept Clin Med, Copenhagen, Denmark
[4] Copenhagen Univ Hosp Herlev & Gentofte, Dept Med, Herlev, Denmark
关键词
Olink immuno-oncology; Proximity extension assay; Multiplex Immunoassays; Proteins; Tumor markers; Serum-plasma variability;
D O I
10.1186/s12014-022-09380-y
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Background Proximity extension assay (PEA) is a novel antibody-based proteomic technology. Sparse data have been published concerning the matrix effect of serum vs. ethylenediamine tetraacetic acid (EDTA) plasma and the reproducibility of results obtained using PEA technology. Methods We analyzed samples with the PEA-based 92-plex Olink (R) immuno-oncology (I-O) assay. To estimate the matrix effect, we analyzed paired serum and EDTA plasma samples from 12 patients with biliary tract cancer. To evaluate the reproducibility, we used data from 7 studies, where 6-8 serum samples from patients with pancreatic cancer were used as bridging samples on 3 versions of the panel over a 2.5-years period. Results For the study of serum vs. plasma, 80 proteins were evaluable. The mean serum to EDTA plasma ratio ranged from 0.41-3.01. For 36 proteins, the serum and plasma values were not comparable due to high variability of the ratio, poor correlation, or possible concentration effect. For the bridging samples, the mean intra-study inter-assay coefficient of variation (CV) ranged from 11.3% to 26.1%. The mean inter-study CV was 42.0% before normalization and 26.2% after normalization. Inter-study results were well correlated (r >= 0.93), especially for studies using the same version of the panel (r >= 0.99). Conclusion For 44 of 92 proteins included in the Olink (R) I-O panel, the variation between results obtained using serum and EDTA plasma was constant and results were well correlated. Furthermore, samples could be stored for several years and used on different versions of the same PEA panel without it effecting results.
引用
收藏
页数:17
相关论文
共 18 条
[1]  
[Anonymous], OL VAL DAT DOC V 2 1
[2]  
[Anonymous], 2020, White Paper 5G Evolution and 6G
[3]   Transcriptomic and proteomic intra-tumor heterogeneity of colorectal cancer varies depending on tumor location within the colorectum [J].
arnadottir, Sigrid Salling ;
Mattesen, Trine Block ;
Vang, Soren ;
Madsen, Mogens Rorbaek ;
Madsen, Anders Husted ;
Birkbak, Nicolai Juul ;
Bramsen, Jesper Bertram ;
Andersen, Claus Lindbjerg .
PLOS ONE, 2020, 15 (12)
[4]   Homogenous 96-Plex PEA Immunoassay Exhibiting High Sensitivity, Specificity, and Excellent Scalability [J].
Assarsson, Erika ;
Lundberg, Martin ;
Holmquist, Goeran ;
Bjoerkesten, Johan ;
Thorsen, Stine Bucht ;
Ekman, Daniel ;
Eriksson, Anna ;
Dickens, Emma Rennel ;
Ohlsson, Sandra ;
Edfeldt, Gabriella ;
Andersson, Ann-Catrin ;
Lindstedt, Patrik ;
Stenvang, Jan ;
Gullberg, Mats ;
Fredriksson, Simon .
PLOS ONE, 2014, 9 (04)
[5]   Serum Biomarker Panels for the Detection of Pancreatic Cancer [J].
Brand, Randall E. ;
Nolen, Brian M. ;
Zeh, Herbert J. ;
Allen, Peter J. ;
Eloubeidi, Mohamad A. ;
Goldberg, Michael ;
Elton, Eric ;
Arnoletti, Juan P. ;
Christein, John D. ;
Vickers, Selwyn M. ;
Langmead, Christopher J. ;
Landsittel, Douglas P. ;
Whitcomb, David C. ;
Grizzle, William E. ;
Lokshin, Anna E. .
CLINICAL CANCER RESEARCH, 2011, 17 (04) :805-816
[6]   Profiling of donor-specific immune effector signatures in response to rituximab in a human whole blood loop assay using blood from CLL patients [J].
Eltahir, M. ;
Fletcher, E. ;
Dynesius, L. ;
Jarblad, J. L. ;
Lord, M. ;
Lauren, I. ;
Zekarias, M. ;
Yu, X. ;
Cragg, M. S. ;
Hammarstrom, C. ;
Levedahl, K. H. ;
Hoglund, M. ;
Ullenhag, G. ;
Mattsson, M. ;
Mangsbo, S. M. .
INTERNATIONAL IMMUNOPHARMACOLOGY, 2021, 90
[7]   High throughput proteomics identifies a high-accuracy 11 plasma protein biomarker signature for ovarian cancer [J].
Enroth, Stefan ;
Berggrund, Malin ;
Lycke, Maria ;
Broberg, John ;
Lundberg, Martin ;
Assarsson, Erika ;
Olovsson, Matts ;
Stalberg, Karin ;
Sundfeldt, Karin ;
Gyllensten, Ulf .
COMMUNICATIONS BIOLOGY, 2019, 2 (1)
[8]   Effects of Long-Term Storage Time and Original Sampling Month on Biobank Plasma Protein Concentrations [J].
Enroth, Stefan ;
Hallmans, Goran ;
Grankvist, Kjell ;
Gyllensten, Ulf .
EBIOMEDICINE, 2016, 12 :309-314
[9]   Defining Clinical Utility of Tumor Biomarker Tests: A Clinician's Viewpoint [J].
Hayes, Daniel F. .
JOURNAL OF CLINICAL ONCOLOGY, 2021, 39 (03) :238-+
[10]   Cancer biomarker discovery and translation: proteomics and beyond [J].
Hristova, Ventzislava A. ;
Chan, Daniel W. .
EXPERT REVIEW OF PROTEOMICS, 2019, 16 (02) :93-103