Percutaneous lead extraction and repositioning: An effective and safe therapeutic strategy for early ventricular lead perforation with dislocation both inside and outside the pericardial sac following a cardiac device implantation

被引:10
作者
Archontakis, Stefanos [1 ]
Sideris, Konstantinos [2 ]
Aggeli, Konstantina [1 ]
Gatzoulis, Konstantinos [1 ]
Demosthenous, Michael [3 ]
Tolios, Panagiotis [1 ]
Lozos, Vasilios [1 ]
Koumallos, Nikolas [3 ]
Limperiadis, Dimitrios [3 ]
Tousoulis, Dimitrios [1 ]
Kallikazaros, Ioannis [2 ]
Sideris, Skevos [2 ]
机构
[1] Univ Athens, Hippokrat Gen Hosp, Cardiol Div 1, Athens, Greece
[2] Hippokrateion Hosp, Dept Cardiol, 4 Evrou St, Athens 11528, Greece
[3] Hippokrateion Hosp, Dept Cardiac Surg, Athens, Greece
关键词
cardiac lead perforation; cardiac tamponade; implantable cardioverter defibrillator; pacemaker; ventricular perforation; CARDIOVERTER-DEFIBRILLATORS; RESYNCHRONIZATION THERAPY; MANAGEMENT; COMPLICATIONS; PREDICTORS; PACEMAKER;
D O I
10.1111/jce.13804
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction Cardiac perforation of the right ventricle associated with pacemaker or implantable cardioverter defibrillator (ICD) leads' implantation is uncommon, albeit potentially life-threatening, complication. The aim of this study is to further identify the optimal therapeutic strategy, especially when lead dislocation has occurred outside the pericardial sac. Methods and Results The study population included 10 consecutive patients (six female, mean age: 66.5 years old) diagnosed with early ventricular lead perforation following a pacemaker or ICD implantation, with significant protrusion inside the pericardial sac (n = 2) or migration of the lead at the pleural space (n = 3), the diaphragm (n = 1), or the abdominal cavity (n = 4), during the period 2013-2017. All patients were symptomatic; however, individuals presenting with hemodynamic instability were excluded. The outcome of the percutaneous therapeutic approach was retrospectively assessed. All patients underwent a successful removal of the perforating lead percutaneously at the electrophysiology lab, by direct traction, and repositioning in another location of the right ventricle. The operation was performed by a multidisciplinary team, under continuous hemodynamic and transesophageal echocardiographic monitoring and cardiac surgical backup. The periprocedural period was uneventful. Subjects were followed up for at least 1 year. Interestingly, all patients developed a type of postcardiac injury syndrome, successfully treated with a 3-month regimen of ibuprofen and colchicine. Conclusion Percutaneous traction and repositioning of the perforating ventricular lead are effective, safe, and less invasive compared with the thoracotomy method in hemodynamically stable patients when dislocation has occurred outside the pericardial sac provided that there is no visceral organs injury.
引用
收藏
页码:299 / 307
页数:9
相关论文
共 20 条
[1]   2013 ESC Guidelines on cardiac pacing and cardiac resynchronization therapy The Task Force on cardiac pacing and resynchronization therapy of the European Society of Cardiology (ESC). Developed in collaboration with the European Heart Rhythm Association (EHRA) [J].
Brignole, Michele ;
Auricchio, Angelo ;
Baron-Esquivias, Gonzalo ;
Bordachar, Pierre ;
Boriani, Giuseppe ;
Breithardt, Ole-A ;
Cleland, John ;
Deharo, Jean-Claude ;
Delgado, Victoria ;
Elliott, Perry M. ;
Gorenek, Bulent ;
Israel, Carsten W. ;
Leclercq, Christophe ;
Linde, Cecilia ;
Mont, Lluis ;
Padeletti, Luigi ;
Sutton, Richard ;
Vardas, Panos E. ;
Luis Zamorano, Jose ;
Achenbach, Stephan ;
Baumgartner, Helmut ;
Bax, Jeroen J. ;
Bueno, Hector ;
Dean, Veronica ;
Deaton, Christi ;
Erol, Cetin ;
Fagard, Robert ;
Ferrari, Roberto ;
Hasdai, David ;
Hoes, Arno W. ;
Kirchhof, Paulus ;
Knuuti, Juhani ;
Kolh, Philippe ;
Lancellotti, Patrizio ;
Linhart, Ales ;
Nihoyannopoulos, Petros ;
Piepoli, Massimo F. ;
Ponikowski, Piotr ;
Sirnes, Per Anton ;
Luis Tamargo, Juan ;
Tendera, Michal ;
Torbicki, Adam ;
Wijns, William ;
Windecker, Stephan ;
Kirchhof, Paulus ;
Blomstrom-Lundqvist, Carina ;
Badano, Luigi P. ;
Aliyev, Farid ;
Baensch, Dietmar ;
Baumgartner, Helmut .
EUROPEAN HEART JOURNAL, 2013, 34 (29) :2281-2329
[2]   Incidence and predictors of clinically relevant cardiac perforation associated with systematic implantation of active-fixation pacing and defibrillation leads: a single-centre experience with over 3800 implanted leads [J].
Cano, Oscar ;
Andres, Ana ;
Alonso, Pau ;
Osca, Joaquin ;
Sancho-Tello, Maria-Jose ;
Olague, Jose ;
Martinez-Dolz, Luis .
EUROPACE, 2017, 19 (01) :96-102
[3]   Complications arising after implantation of DDD pacemakers: The MOST experience [J].
Ellenbogen, KA ;
Hellkamp, AS ;
Wilkoff, BL ;
Camunas, JL ;
Love, JC ;
Hadjis, TA ;
Lee, KL ;
Lamas, GA .
AMERICAN JOURNAL OF CARDIOLOGY, 2003, 92 (06) :740-741
[4]   Post-cardiac injury syndrome after permanent electronic cardiac device implantation. Incidence, presentation, management and long-term prognosis [J].
Gatzoulis, Konstantinos ;
Archontakis, Stefanos ;
Tsiachris, Dimitrios ;
Lazaros, George ;
Apostolopoulos, Theodoros ;
Zervopoulos, George ;
Costeas, Xenofon ;
Dilaveris, Polychronis ;
Sideris, Skevos ;
Kallikazaros, Ioannis ;
Stefanadis, Christodoulos .
INTERNATIONAL JOURNAL OF CARDIOLOGY, 2014, 174 (01) :163-164
[5]   Cardiac tamponade as complication of active-fixation atrial lead perforations: Proposed mechanism and management algorithm [J].
Geyfman, Vitaly ;
Storm, Randle H. ;
Lico, Serrie C. ;
Oren, Jess W. .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2007, 30 (04) :498-501
[6]  
Hirschl DA, 2007, PACE, V30, P28
[7]   Delayed lead perforation: A disturbing trend [J].
Khan, MN ;
Joseph, G ;
Khaykin, Y ;
Ziada, KM ;
Wilkoff, BL .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2005, 28 (03) :251-253
[8]   Complications after cardiac implantable electronic device implantations: an analysis of a complete, nationwide cohort in Denmark [J].
Kirkfeldt, Rikke Esberg ;
Johansen, Jens Brock ;
Nohr, Ellen Aagaard ;
Jorgensen, Ole Dan ;
Nielsen, Jens Cosedis .
EUROPEAN HEART JOURNAL, 2014, 35 (18) :1186-1194
[9]   Annual rate of transvenous defibrillation lead defects in implantable cardioverter-defibrillators over a period of > 10 years [J].
Kleemann, Thomas ;
Becker, Torsten ;
Doenges, Klaus ;
Vater, Margit ;
Senges, Jochen ;
Schneider, Steffen ;
Saggau, Werner ;
Weisse, Udo ;
Seidl, Karlheinz .
CIRCULATION, 2007, 115 (19) :2474-2480
[10]   Management of Subacute and Delayed Right Ventricular Perforation With a Pacing or an Implantable Cardioverter-Defibrillator Lead [J].
Laborderie, Julien ;
Barandon, Laurent ;
Ploux, Sylvain ;
Deplagne, Antoine ;
Mokrani, Bilel ;
Reuter, Sylvain ;
Le Gal, Francois ;
Jais, Pierre ;
Haissaguerre, Michel ;
Clementy, Jacques ;
Bordachar, Pierre .
AMERICAN JOURNAL OF CARDIOLOGY, 2008, 102 (10) :1352-1355