PET-MR imaging using a tri-modality PET/CT-MR system with a dedicated shuttle in clinical routine

被引:78
|
作者
Veit-Haibach, Patrick [1 ]
Kuhn, Felix Pierre [1 ]
Wiesinger, Florian [2 ]
Delso, Gaspar [1 ,3 ]
von Schulthess, Gustav [1 ]
机构
[1] Univ Zurich Hosp, Dept Med Imaging, CH-8091 Zurich, Switzerland
[2] GE Healthcare, Garching, Germany
[3] GE Healthcare, Waukesha, WI USA
关键词
PET/CT; PET/MRI; PET/CT-MRI; Multi-modality imaging; Protocol evaluation; ATTENUATION CORRECTION; MAGNETIC-RESONANCE; FDG-PET/CT; MUSCULOSKELETAL INFECTION; C-11-CHOLINE PET/CT; PROSTATE-CANCER; LARGE-BOWEL; PET/MRI; CT; ATLAS;
D O I
10.1007/s10334-012-0344-5
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Tri-modality PET/CT-MRI includes the transfer of the patient on a dedicated shuttle from one system into the other. Advantages of this system include a true CT-based attenuation correction, reliable PET-quantification and higher flexibility in patient throughput on both systems. Comparative studies of PET/MRI versus PET/CT are readily accomplished without repeated PET with a different PET scanner at a different time point. Additionally, there is a higher imaging flexibility based on the availability of three imaging modalities, which can be combined for the characterization of the disease. The downside is a somewhat higher radiation dose of up to 3 mSv with a low dose CT based on the CT-component, longer acquisition times and potential misalignment between the imaging components. Overall, the tri-modality PET/CT-MR system offers comparative studies using the three different imaging modalities in the same patient virtually at the same time, and may help to develop reliable attenuation algorithms at the same time.
引用
收藏
页码:25 / 35
页数:11
相关论文
共 50 条
  • [1] PET–MR imaging using a tri-modality PET/CT–MR system with a dedicated shuttle in clinical routine
    Patrick Veit-Haibach
    Felix Pierre Kuhn
    Florian Wiesinger
    Gaspar Delso
    Gustav von Schulthess
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2013, 26 : 25 - 35
  • [2] Crossed Cerebellar Diaschisis Three Case Reports Imaging Using a Tri-Modality PET/CT-MR System
    Han, Shuguang
    Wang, Xiaopeng
    Xu, Kai
    Hu, Chunfeng
    MEDICINE, 2016, 95 (02)
  • [3] Image Registration Accuracy of a Sequential, Tri-modality PET/CT plus MR Imaging Setup Using Dedicated Patient Transporter Systems
    Samarin, A.
    Kuhn, F. P.
    Crook, D. W.
    Wiesinger, F.
    Wollenweber, S. D.
    von Schulthess, G. K.
    Hodler, J.
    Schmid, D. T.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2011, 38 : S220 - S220
  • [4] MOLECULAR IMAGING WITH PET-CT AND PET-MR
    Beuthien-Baumann, B.
    RADIOTHERAPY AND ONCOLOGY, 2012, 104 : 27 - 27
  • [5] EANM guidelines for PET-CT and PET-MR routine quality control
    Koole, Michel
    Armstrong, Ian
    Krizsan, Aron K.
    Stromvall, Anne
    Visvikis, Dimitris
    Sattler, Bernhard
    Nekolla, Stephan G.
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2023, 33 (01): : 103 - 113
  • [6] Clinical comparison of a whole-body PET-MR system with PET-CT
    Machac, Josef
    Izquierdo-Garcia, David
    Knesaurek, Karin
    Rafique, Ash
    Davies, Olufunke
    Fuster, Valentin
    Fayad, Zahi
    JOURNAL OF NUCLEAR MEDICINE, 2012, 53
  • [7] Comparison of 68Ga-PSMA and 11C-Choline using a try-modality PET/CT-MR (3.0T) system with a dedicated shuttle
    Alonso, O.
    dos Santos, G.
    Garcia Fontes, M.
    Rodriguez Taroco, M.
    Engler, H.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2016, 43 : S138 - S139
  • [8] Evaluation of dedicated PET/MR breast coil in integrated PET/MR system for simultaneous PET/MR breast imaging
    Cho, Ihn Ho
    Kong, Eun-jung
    Chun, KyunghAh
    Jeong, Ju Hye
    Kwon, SangDon
    JOURNAL OF NUCLEAR MEDICINE, 2015, 56 (03)
  • [9] Quantitative Simultaneous PET-MR Imaging
    Ouyang, Jinsong
    Petibon, Yoann
    Huang, Chuan
    Reese, Timothy G.
    Kolnick, Aleksandra L.
    El Fakhri, Georges
    MICRO- AND NANOTECHNOLOGY SENSORS, SYSTEMS, AND APPLICATIONS VI, 2014, 9083
  • [10] PET-MR Imaging in Head and Neck
    Lee, Yueh Z.
    Ramaiho, Joana
    Kessler, Brice
    MAGNETIC RESONANCE IMAGING CLINICS OF NORTH AMERICA, 2017, 25 (02) : 315 - +