Fine-scale motion detection using intrinsic list mode PET information

被引:21
作者
Klein, GJ [1 ]
Reutter, BW [1 ]
Botvinick, EH [1 ]
Budinger, TF [1 ]
Huesman, RH [1 ]
机构
[1] Lawrence Berkeley Natl Lab, Berkeley, CA USA
来源
IEEE WORKSHOP ON MATHEMATICAL METHODS IN BIOMEDICAL IMAGE ANALYSIS, PROCEEDINGS | 2001年
关键词
D O I
10.1109/MMBIA.2001.991701
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Motion during extended nuclear medicine scanning sequences can significantly degrade the quality of reconstructed images. Correction for this motion requires an accurate motion sensor. We describe a technique to detect motion in list mode positron emission tomography (PET) imagery that relies upon information from the list mode data stream itself. In studies where the tracer contrast to background contrast is high, the axial component of the center of mass (CM) for tomograph events can serve as an accurate indicator of motion. Because the method does not require reconstruction of images, it may be applied to motion detection at a very fine temporal scale. The technique has been applied to the detection of motion due to the respiratory cycle in cardiac PET imaging.
引用
收藏
页码:71 / 78
页数:8
相关论文
共 13 条
[1]   DEVELOPMENTS IN DIGITAL-COMPUTER IMPLEMENTATION IN NUCLEAR-MEDICINE IMAGING [J].
BUDINGER, TF ;
HARPOOTLIAN, J .
COMPUTERS AND BIOMEDICAL RESEARCH, 1975, 8 (01) :26-52
[2]   MAGNETIC-RESONANCE IMAGING WITH RESPIRATORY GATING - TECHNIQUES AND ADVANTAGES [J].
EHMAN, RL ;
MCNAMARA, MT ;
PALLACK, M ;
HRICAK, H ;
HIGGINS, CB .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1984, 143 (06) :1175-1182
[3]  
GERMANO G, 1994, J NUCL MED, V35, P1193
[4]  
HOFFMAN EJ, 1979, J COMPUT ASSIST TOMO, V3, P733
[5]  
Huesman RH, 2000, J NUCL MED, V41, p21P
[6]  
Klein G. J., 1997, 1997 IEEE Nuclear Science Symposium Conference Record (Cat. No.97CH36135), P1284, DOI 10.1109/NSSMIC.1997.670546
[7]   A methodology for specifying PET VOI's using multimodality techniques [J].
Klein, GJ ;
Teng, X ;
Jagust, WJ ;
Eberling, JL ;
Acharya, A ;
Reutter, BW ;
Huesman, RH .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1997, 16 (04) :405-415
[8]   Respiration gated radiotherapy treatment: A technical study [J].
Kubo, HD ;
Hill, BC .
PHYSICS IN MEDICINE AND BIOLOGY, 1996, 41 (01) :83-91
[9]   A MONITORING, FEEDBACK, AND TRIGGERING SYSTEM FOR REPRODUCIBLE BREATH-HOLD MR-IMAGING [J].
LIU, YL ;
RIEDERER, SJ ;
ROSSMAN, PJ ;
GRIMM, RC ;
DEBBINS, JP ;
EHMAN, RL .
MAGNETIC RESONANCE IN MEDICINE, 1993, 30 (04) :507-511
[10]   Effects of lung motion and tracer kinetics corrections on PET imaging of pulmonary function [J].
Mijailovich, SM ;
Treppo, S ;
Venegas, JG .