A pitfall in the reconstruction of fibre ODFs using spherical deconvolution of diffusion MRI data

被引:86
|
作者
Parker, G. D. [1 ,2 ,4 ]
Marshall, D. [4 ]
Rosin, P. L. [4 ]
Drage, N. [2 ]
Richmond, S. [2 ]
Jones, D. K. [1 ,3 ]
机构
[1] Cardiff Univ, Sch Psychol, CUBRIC, Cardiff CF24 3AA, S Glam, Wales
[2] Cardiff Univ, Sch Dent, Cardiff CF24 3AA, S Glam, Wales
[3] Cardiff Univ, Neurosci & Mental Hlth Res Inst, Cardiff CF24 3AA, S Glam, Wales
[4] Cardiff Univ, Sch Comp Sci & Informat, Cardiff CF24 3AA, S Glam, Wales
基金
英国惠康基金;
关键词
Spherical harmonic deconvolution; Richardson-Lucy; MRI; Calibration; Tractography; Diffusion tensor imaging; AXON DIAMETER; TENSOR; TRACTOGRAPHY; DENSITY;
D O I
10.1016/j.neuroimage.2012.10.022
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Diffusion weighted (DW) MRI facilitates non-invasive quantification of tissue microstructure and, in combination with appropriate signal processing, three-dimensional estimates of fibrous orientation. In recent years, attention has shifted from the diffusion tensor model, which assumes a unimodal Gaussian diffusion displacement profile to recover fibre orientation (with various well-documented limitations), towards more complex high angular resolution diffusion imaging (HARDI) analysis techniques. Spherical deconvolution (SD) approaches assume that the fibre orientation density function (fODF) within a voxel can be obtained by deconvolving a 'common' single fibre response function from the observed set of DW signals. In practice, this common response function is not known a priori and thus an estimated fibre response must be used. Here the establishment of this single-fibre response function is referred to as 'calibration'. This work examines the vulnerability of two different SD approaches to inappropriate response function calibration: (1) constrained spherical harmonic deconvolution (CSHD) a technique that exploits spherical harmonic basis sets and (2) damped Richardson-Lucy (dRL) deconvolution a technique based on the standard Richardson-Lucy deconvolution. Through simulations, the impact of a discrepancy between the calibrated diffusion profiles and the observed ('Target') OW-signals in both single and crossing-fibre configurations was investigated. The results show that CSHD produces spurious fODF peaks (consistent with well known ringing artefacts) as the discrepancy between calibration and target response increases, while dRL demonstrates a lower over-all sensitivity to miscalibration (with a calibration response function for a highly anisotropic fibre being optimal). However, dRL demonstrates a reduced ability to resolve low anisotropy crossing-fibres compared to CSHD. It is concluded that the range and spatial-distribution of expected single-fibre anisotropies within an image must be carefully considered to ensure selection of the appropriate algorithm, parameters and calibration. Failure to choose the calibration response function carefully may severely impact the quality of any resultant tractography. (C) 2012 Elsevier Inc. All rights reserved.
引用
收藏
页码:433 / 448
页数:16
相关论文
共 50 条
  • [31] Bridging the gap between constrained spherical deconvolution and diffusional variance decomposition via tensor-valued diffusion MRI
    Karan, Philippe
    Reymbaut, Alexis
    Gilbert, Guillaume
    Descoteaux, Maxime
    MEDICAL IMAGE ANALYSIS, 2022, 79
  • [32] Fibre tract segmentation for intraoperative diffusion MRI in neurosurgical patients using tract-specific orientation atlas and tumour deformation modelling
    Young, Fiona
    Aquilina, Kristian
    Clark, Chris A.
    Clayden, Jonathan D.
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2022, 17 (09) : 1559 - 1567
  • [33] Track density imaging using diffusion tensor imaging data from 1.5 T MRI scanner
    Kosker, Fatma Betul
    Gumus, Kazim Ziya
    Tokmakci, Mahmut
    Acer, Niyazi
    Senol, Serkan
    Bilgen, Mehmet
    TURKISH JOURNAL OF ELECTRICAL ENGINEERING AND COMPUTER SCIENCES, 2022, 30 (06) : 2044 - 2053
  • [34] Slice Estimation in Diffusion MRI of Neonatal and Fetal Brains in Image and Spherical Harmonics Domains Using Autoencoders
    Kebiri, Hamza
    Girard, Gabriel
    Aleman-Gomez, Yasser
    Yu, Thomas
    Jakab, Andras
    Canales-Rodriguez, Erick Jorge
    Cuadra, Meritxell Bach
    COMPUTATIONAL DIFFUSION MRI (CDMRI 2022), 2022, 13722 : 3 - 13
  • [35] In vivo microstructural heterogeneity of white matter lesions in healthy elderly and Alzheimer's disease participants using tissue compositional analysis of diffusion MRI data
    Mito, Remika
    Dhollander, Thijs
    Xia, Ying
    Raffelt, David
    Salvado, Olivier
    Churilov, Leonid
    Rowe, Christopher C.
    Brodtmann, Amy
    Villemagne, Victor L.
    Connelly, Alan
    NEUROIMAGE-CLINICAL, 2020, 28
  • [36] Joint reconstruction of white-matter pathways from longitudinal diffusion MRI data with anatomical priors
    Yendiki, Anastasia
    Reuter, Martin
    Wilkens, Paul
    Rosas, H. Diana
    Fischl, Bruce
    NEUROIMAGE, 2016, 127 : 277 - 286
  • [37] Atlas-based fiber reconstruction from diffusion tensor MRI data
    Barbieri, Sebastiano
    Klein, Jan
    Bauer, Miriam H. A.
    Nimsky, Christopher
    Hahn, Horst K.
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2012, 7 (06) : 959 - 967
  • [38] Atlas-based fiber reconstruction from diffusion tensor MRI data
    Sebastiano Barbieri
    Jan Klein
    Miriam H. A. Bauer
    Christopher Nimsky
    Horst K. Hahn
    International Journal of Computer Assisted Radiology and Surgery, 2012, 7 : 959 - 967
  • [39] Axonal T2 estimation using the spherical variance of the strongly diffusion-weighted MRI signal
    Pizzolato, Marco
    Andersson, Mariam
    Canales-Rodriguez, Erick Jorge
    Thiran, Jean-Philippe
    Dyrby, Tim B.
    MAGNETIC RESONANCE IMAGING, 2022, 86 : 118 - 134
  • [40] Connectivity analysis of anterior nuclei of the thalamus in diffusion- MRI using constrained spherical deconvolution (CSD), multi-shell multi-tissue CSD and probabilistic DTI for ANT-DBS in epilepsy
    Ozdemir, Ruhunur
    Lehtimaki, Kai
    Peltola, Jukka
    Eskola, Hannu
    MEDICAL IMAGING 2020: BIOMEDICAL APPLICATIONS IN MOLECULAR, STRUCTURAL, AND FUNCTIONAL IMAGING, 2021, 11317