Fabrication of a Ratiometric Fluorescence Sensor Based on Carbon Dots as Both Luminophores and Nanozymes for the Sensitive Detection of Hydrogen Peroxide

被引:23
|
作者
Li, Yutong [1 ]
Gu, Xinhui [1 ]
Zhao, Jiayin [2 ]
Xi, Fengna [1 ]
机构
[1] Zhejiang Sci Tech Univ, Dept Chem, Key Lab Surface & Interface Sci Polymer Mat Zheji, Hangzhou 310018, Peoples R China
[2] Text Ind Prod Testing Ctr Nanjing Customs Dist, Wuxi 210001, Jiangsu, Peoples R China
来源
MOLECULES | 2022年 / 27卷 / 21期
基金
中国国家自然科学基金;
关键词
fluorescent nanozymes; carbon dots; ratiometric fluorescence; fluorescence resonance energy transfer; hydrogen peroxide; GRAPHENE QUANTUM DOTS; COLORIMETRIC DETECTION; MIMETIC ACTIVITY; H2O2; IRON;
D O I
10.3390/molecules27217379
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
The construction of novel fluorescent nanozymes is highly desirable for providing new strategies for nanozyme-based sensing systems. Herein, a novel ratiometric fluorescence sensing platform was constructed based on carbon dots (CDs) as both luminophores and nanozymes, which could realize the sensitive detection of hydrogen peroxide (H2O2). CDs with peroxidase-mimicking activity were prepared with a one-step hydrothermal method using L-histidine as an inexpensive precursor. CDs had bright blue fluorescence. Due to the pseudo-peroxidase activity, CDs catalyzed the oxidation of o-phenylenediamine (OPD) with H2O2 to generate 2,3-diaminophenolazine (DAP). The fluorescence resonance energy transfer (FRET) between CDs and DAP resulted in a decrease in the fluorescence of CDs and an increase in the fluorescence of DAP, leading to a ratiometric fluorescence system. The free radical trapping experiment was used to investigate the reactive oxygen radicals (ROS) in the catalytic process of CD nanozymes. The enzymatic parameters of CD nanozymes, including the Michaelis constant (K-m) and the maximum initial reaction velocities (V-max), were investigated. A good affinity for both OPD and H2O2 substrates was proven. Based on the FRET between CDs and OPD, a ratiometric fluorescence analysis of H2O2 was achieved and results ranged from 1 to 20 mu M and 20 to 200 mu M with a low limit of detection (LOD, 0.42 mu M). The detection of H2O2 in milk was also achieved.
引用
收藏
页数:17
相关论文
共 50 条
  • [41] A ratiometric fluorescence sensor for highly selective and sensitive detection of mercuric ion
    Ma, Fang
    Sun, Mingtai
    Zhang, Kui
    Wang, Suhua
    SENSORS AND ACTUATORS B-CHEMICAL, 2015, 209 : 377 - 383
  • [42] Immobilization of horseradish peroxidase on amino-functionalized carbon dots for the sensitive detection of hydrogen peroxide
    Su, Ya
    Zhou, Xuan
    Long, Yumei
    Li, Weifeng
    MICROCHIMICA ACTA, 2018, 185 (02)
  • [43] Tb doped carbon dots as a platform for fluorescence ratiometric and colorimetric sensor for deferasirox
    Fatemeh Latifi
    Mohammad Amjadi
    Tooba Hallaj
    Seyyed Morteza Seyyed Alavi
    Scientific Reports, 15 (1)
  • [44] Ratiometric fluorescent nanosensor based on carbon dots for the detection of mercury ion
    Ma, Yusha
    Mei, Jing
    Bai, Jianliang
    Chen, Xu
    Ren, Lili
    MATERIALS RESEARCH EXPRESS, 2018, 5 (05):
  • [45] A ratiometric fluorescence platform based on carbon dots for visual and rapid detection of copper(II) and fluoroquinolones
    Gao, Xue
    Sun, Minjun
    Liu, Xiuying
    Li, Xuepeng
    Li, Jianrong
    MICROCHIMICA ACTA, 2022, 189 (04)
  • [46] Ratiometric fluorescence biosensor based on CdTe quantum and carbon dots for double strand DNA detection
    Liang, Si-Si
    Qi, Liang
    Zhang, Rui-Ling
    Jin, Meng
    Zhang, Zhi-Qi
    SENSORS AND ACTUATORS B-CHEMICAL, 2017, 244 : 585 - 590
  • [47] A ratiometric fluorescence platform based on carbon dots for visual and rapid detection of copper(II) and fluoroquinolones
    Xue Gao
    Minjun Sun
    Xiuying Liu
    Xuepeng Li
    Jianrong Li
    Microchimica Acta, 2022, 189
  • [48] Ratiometric Fluorescence Assay for Visual Detection of Tetracycline Residues based on the Complex of Carbon Dots and Europium
    Yang Weiqiang
    Zhang Guiyun
    Lin Hua
    Ni Jiancong
    Huang Lingfeng
    CHEMICAL JOURNAL OF CHINESE UNIVERSITIES-CHINESE, 2019, 40 (11): : 2294 - 2300
  • [49] Sensitive detection of hydrogen peroxide and nitrite based on silver/carbon nanocomposite synthesized by carbon dots as reductant via one step method
    Zhang, Si
    Liu, Xiaoying
    Huang, Na
    Lu, Qiujun
    Liu, Meiling
    Li, Haitao
    Zhang, Youyu
    Yao, Shouzhuo
    ELECTROCHIMICA ACTA, 2016, 211 : 36 - 43
  • [50] Highly sensitive and ratiometric detection of nitrite in food based on upconversion-carbon dots nanosensor
    Yang, Yaqing
    Wei, Simin
    Wang, Jialin
    Li, Junjie
    Tang, Jinlu
    Aaron, Albert Aryee
    Cai, Qiyong
    Wang, Ningning
    Li, Zhaohui
    ANALYTICA CHIMICA ACTA, 2023, 1263