Fabrication of a Ratiometric Fluorescence Sensor Based on Carbon Dots as Both Luminophores and Nanozymes for the Sensitive Detection of Hydrogen Peroxide

被引:23
|
作者
Li, Yutong [1 ]
Gu, Xinhui [1 ]
Zhao, Jiayin [2 ]
Xi, Fengna [1 ]
机构
[1] Zhejiang Sci Tech Univ, Dept Chem, Key Lab Surface & Interface Sci Polymer Mat Zheji, Hangzhou 310018, Peoples R China
[2] Text Ind Prod Testing Ctr Nanjing Customs Dist, Wuxi 210001, Jiangsu, Peoples R China
来源
MOLECULES | 2022年 / 27卷 / 21期
基金
中国国家自然科学基金;
关键词
fluorescent nanozymes; carbon dots; ratiometric fluorescence; fluorescence resonance energy transfer; hydrogen peroxide; GRAPHENE QUANTUM DOTS; COLORIMETRIC DETECTION; MIMETIC ACTIVITY; H2O2; IRON;
D O I
10.3390/molecules27217379
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
The construction of novel fluorescent nanozymes is highly desirable for providing new strategies for nanozyme-based sensing systems. Herein, a novel ratiometric fluorescence sensing platform was constructed based on carbon dots (CDs) as both luminophores and nanozymes, which could realize the sensitive detection of hydrogen peroxide (H2O2). CDs with peroxidase-mimicking activity were prepared with a one-step hydrothermal method using L-histidine as an inexpensive precursor. CDs had bright blue fluorescence. Due to the pseudo-peroxidase activity, CDs catalyzed the oxidation of o-phenylenediamine (OPD) with H2O2 to generate 2,3-diaminophenolazine (DAP). The fluorescence resonance energy transfer (FRET) between CDs and DAP resulted in a decrease in the fluorescence of CDs and an increase in the fluorescence of DAP, leading to a ratiometric fluorescence system. The free radical trapping experiment was used to investigate the reactive oxygen radicals (ROS) in the catalytic process of CD nanozymes. The enzymatic parameters of CD nanozymes, including the Michaelis constant (K-m) and the maximum initial reaction velocities (V-max), were investigated. A good affinity for both OPD and H2O2 substrates was proven. Based on the FRET between CDs and OPD, a ratiometric fluorescence analysis of H2O2 was achieved and results ranged from 1 to 20 mu M and 20 to 200 mu M with a low limit of detection (LOD, 0.42 mu M). The detection of H2O2 in milk was also achieved.
引用
收藏
页数:17
相关论文
共 50 条
  • [41] Ratiometric fluorescence probe based on carbon dots and p-phenylenediamine-derived nanoparticles for the sensitive detection of manganese ions
    Hu, Anqi
    Chen, Guoqing
    Huang, Anlan
    Li, Lei
    Ma, Chaoqun
    Yang, Taiqun
    Gao, Hui
    Gu, Jiao
    Zhu, Chun
    Shang, Yunpeng
    Wu, Yamin
    MICROCHIMICA ACTA, 2024, 191 (09)
  • [42] Sensitive ratiometric fluorescence probe based on chitosan carbon dots and calcein for Alkaline phosphatase detection and bioimaging in cancer cells
    Mu, Xiaowei
    Jiang, Xue
    Zhang, Yu
    Liu, Xin
    Zhang, Siqi
    Wang, Wei
    Huang, Yibing
    Ma, Pinyi
    Song, Daqian
    ANALYTICA CHIMICA ACTA, 2021, 1188 (1188)
  • [43] A triple-emission ratiometric fluorescence sensor based on carbon dots-Au nanoclusters nanocomposite for detection of tetracycline
    Miao, Jiaqi
    Ji, Wan
    Yu, Jialuo
    Cheng, Jianxia
    Huang, Yan
    Arabi, Maryam
    Zhou, Na
    Li, Bowei
    Zhang, Zhiyang
    Chen, Lingxin
    Wang, Xiaoyan
    SENSORS AND ACTUATORS B-CHEMICAL, 2023, 384
  • [44] Carbon dots based multicolor fluorescence sensor for ratiometric and colorimetric dual-model detection of Cu2+
    Huang, Gengli
    Luo, Xueli
    Lin, Wanmei
    Tang, Wenzhi
    Yue, Tianli
    Wang, Jianlong
    Li, Zhonghong
    DYES AND PIGMENTS, 2022, 203
  • [45] The miniature self-correcting ratiometric fluorescence optical fiber sensor based on carbon dots for chromium (VI) detection
    Cai Y.
    Jiang T.
    Zhang J.
    Li Y.
    Zhao Y.
    Yi Qi Yi Biao Xue Bao/Chinese Journal of Scientific Instrument, 2023, 44 (11): : 261 - 270
  • [46] Ratiometric fluorescence sensor for the sensitive detection of Bacillus thuringiensis transgenic sequence based on silica coated supermagnetic nanoparticles and quantum dots
    Wu, Long
    Deng, Jiamin
    Tan, Xuecai
    Yin, Wenmin
    Ding, Fan
    Han, Heyou
    SENSORS AND ACTUATORS B-CHEMICAL, 2018, 254 : 206 - 213
  • [47] Novel peroxiredoxin-based sensor for sensitive detection of hydrogen peroxide
    Yang, Yuhong
    Zhou, Yao
    Li, Jingyi
    Yu, Haijun
    Takaya, Naoki
    Wang, Ping
    Zhou, Shengmin
    BIOCHEMICAL AND BIOPHYSICAL RESEARCH COMMUNICATIONS, 2019, 517 (02) : 260 - 265
  • [48] Synthesis of catalytically active peroxidase-like Fe-doped carbon dots and application in ratiometric fluorescence detection of hydrogen peroxide and glucose
    Zhu, Dan
    Zhuo, Shujuan
    Zhu, Changqing
    Zhang, Ping
    Shen, Weili
    ANALYTICAL METHODS, 2019, 11 (20) : 2663 - 2668
  • [49] Current Progress of Ratiometric Fluorescence Sensors Based on Carbon Dots in Foodborne Contaminant Detection
    Zhang, Jialu
    Chen, Huinan
    Xu, Kaidi
    Deng, Dongmei
    Zhang, Qixian
    Luo, Liqiang
    BIOSENSORS-BASEL, 2023, 13 (02):
  • [50] Hydrogel Optical Fiber Based Ratiometric Fluorescence Sensor for Highly Sensitive Ph Detection
    Zhao, Lishuai
    Li, Guoqiang
    Gan, Jiulin
    Yang, Zhongmin
    JOURNAL OF LIGHTWAVE TECHNOLOGY, 2021, 39 (20) : 6653 - 6659