Fabrication of a Ratiometric Fluorescence Sensor Based on Carbon Dots as Both Luminophores and Nanozymes for the Sensitive Detection of Hydrogen Peroxide

被引:23
|
作者
Li, Yutong [1 ]
Gu, Xinhui [1 ]
Zhao, Jiayin [2 ]
Xi, Fengna [1 ]
机构
[1] Zhejiang Sci Tech Univ, Dept Chem, Key Lab Surface & Interface Sci Polymer Mat Zheji, Hangzhou 310018, Peoples R China
[2] Text Ind Prod Testing Ctr Nanjing Customs Dist, Wuxi 210001, Jiangsu, Peoples R China
来源
MOLECULES | 2022年 / 27卷 / 21期
基金
中国国家自然科学基金;
关键词
fluorescent nanozymes; carbon dots; ratiometric fluorescence; fluorescence resonance energy transfer; hydrogen peroxide; GRAPHENE QUANTUM DOTS; COLORIMETRIC DETECTION; MIMETIC ACTIVITY; H2O2; IRON;
D O I
10.3390/molecules27217379
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
The construction of novel fluorescent nanozymes is highly desirable for providing new strategies for nanozyme-based sensing systems. Herein, a novel ratiometric fluorescence sensing platform was constructed based on carbon dots (CDs) as both luminophores and nanozymes, which could realize the sensitive detection of hydrogen peroxide (H2O2). CDs with peroxidase-mimicking activity were prepared with a one-step hydrothermal method using L-histidine as an inexpensive precursor. CDs had bright blue fluorescence. Due to the pseudo-peroxidase activity, CDs catalyzed the oxidation of o-phenylenediamine (OPD) with H2O2 to generate 2,3-diaminophenolazine (DAP). The fluorescence resonance energy transfer (FRET) between CDs and DAP resulted in a decrease in the fluorescence of CDs and an increase in the fluorescence of DAP, leading to a ratiometric fluorescence system. The free radical trapping experiment was used to investigate the reactive oxygen radicals (ROS) in the catalytic process of CD nanozymes. The enzymatic parameters of CD nanozymes, including the Michaelis constant (K-m) and the maximum initial reaction velocities (V-max), were investigated. A good affinity for both OPD and H2O2 substrates was proven. Based on the FRET between CDs and OPD, a ratiometric fluorescence analysis of H2O2 was achieved and results ranged from 1 to 20 mu M and 20 to 200 mu M with a low limit of detection (LOD, 0.42 mu M). The detection of H2O2 in milk was also achieved.
引用
收藏
页数:17
相关论文
共 50 条
  • [31] Ratiometric fluorescence sensor for the sensitive detection of Bacillus thuringiensis transgenic sequence based on silica coated supermagnetic nanoparticles and quantum dots
    Wu, Long
    Deng, Jiamin
    Tan, Xuecai
    Yin, Wenmin
    Ding, Fan
    Han, Heyou
    SENSORS AND ACTUATORS B-CHEMICAL, 2018, 254 : 206 - 213
  • [32] Carbon dots based multicolor fluorescence sensor for ratiometric and colorimetric dual-model detection of Cu2+
    Huang, Gengli
    Luo, Xueli
    Lin, Wanmei
    Tang, Wenzhi
    Yue, Tianli
    Wang, Jianlong
    Li, Zhonghong
    DYES AND PIGMENTS, 2022, 203
  • [33] The miniature self-correcting ratiometric fluorescence optical fiber sensor based on carbon dots for chromium (VI) detection
    Cai Y.
    Jiang T.
    Zhang J.
    Li Y.
    Zhao Y.
    Yi Qi Yi Biao Xue Bao/Chinese Journal of Scientific Instrument, 2023, 44 (11): : 261 - 270
  • [34] Novel peroxiredoxin-based sensor for sensitive detection of hydrogen peroxide
    Yang, Yuhong
    Zhou, Yao
    Li, Jingyi
    Yu, Haijun
    Takaya, Naoki
    Wang, Ping
    Zhou, Shengmin
    BIOCHEMICAL AND BIOPHYSICAL RESEARCH COMMUNICATIONS, 2019, 517 (02) : 260 - 265
  • [35] Development of a novel fluorescence ratiometric glucose sensor based on carbon dots and a potential fluorophore m-dihydroxybenzene
    Zhai, Hong
    Bai, Yunfeng
    Wang, Haiqing
    Qin, Jun
    Liu, Huijun
    Feng, Feng
    ANALYTICAL METHODS, 2018, 10 (45) : 5380 - 5386
  • [36] Current Progress of Ratiometric Fluorescence Sensors Based on Carbon Dots in Foodborne Contaminant Detection
    Zhang, Jialu
    Chen, Huinan
    Xu, Kaidi
    Deng, Dongmei
    Zhang, Qixian
    Luo, Liqiang
    BIOSENSORS-BASEL, 2023, 13 (02):
  • [37] Ratiometric fluorescence probe based on boric acid-modified carbon dots and alizarin red for sensitive and rapid detection of glyphosate
    Yang, Jingqi
    Wang, Xinru
    Yu, Ying
    Cao, Yujuan
    Guo, Manli
    Hu, Xiaogang
    Wang, Li
    Lin, Bixia
    MICROCHIMICA ACTA, 2024, 191 (11)
  • [38] Fluorescent Carbon Dots Illuminate Hydrogen Peroxide Detection: A Promising Approach
    Sanchez Fonseca, Jessica D.
    Bonilla Fajardo, Nicolas J.
    Vargas Perdomo, Natalia
    Perdomo Charry, Oscar Julian
    Orjuela-Canon, Alvaro D.
    Martin Rodriguez, Emma
    Rodriguez Burbano, Diana C.
    2023 IEEE 3RD COLOMBIAN BIOCAS WORKSHOP, 2023,
  • [39] Highly selective and sensitive determination of ceftriaxone sodium using nitrogen-rich carbon dots based on ratiometric fluorescence
    Zhang, Qiang
    Wang, Lingxiao
    Su, Pengchen
    Yu, Long
    Yin, Ranhao
    Bu, Yiming
    Hao, Xiangyang
    Sun, Mingtai
    Wang, Suhua
    TALANTA, 2023, 255
  • [40] Nanozyme-based sensitive ratiometric fluorescence detection platform for glucose
    Fu, Qingjie
    Zhou, Xiaobin
    Wang, Mengjun
    Su, Xingguang
    ANALYTICA CHIMICA ACTA, 2022, 1216