Fabrication of a Ratiometric Fluorescence Sensor Based on Carbon Dots as Both Luminophores and Nanozymes for the Sensitive Detection of Hydrogen Peroxide

被引:23
|
作者
Li, Yutong [1 ]
Gu, Xinhui [1 ]
Zhao, Jiayin [2 ]
Xi, Fengna [1 ]
机构
[1] Zhejiang Sci Tech Univ, Dept Chem, Key Lab Surface & Interface Sci Polymer Mat Zheji, Hangzhou 310018, Peoples R China
[2] Text Ind Prod Testing Ctr Nanjing Customs Dist, Wuxi 210001, Jiangsu, Peoples R China
来源
MOLECULES | 2022年 / 27卷 / 21期
基金
中国国家自然科学基金;
关键词
fluorescent nanozymes; carbon dots; ratiometric fluorescence; fluorescence resonance energy transfer; hydrogen peroxide; GRAPHENE QUANTUM DOTS; COLORIMETRIC DETECTION; MIMETIC ACTIVITY; H2O2; IRON;
D O I
10.3390/molecules27217379
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
The construction of novel fluorescent nanozymes is highly desirable for providing new strategies for nanozyme-based sensing systems. Herein, a novel ratiometric fluorescence sensing platform was constructed based on carbon dots (CDs) as both luminophores and nanozymes, which could realize the sensitive detection of hydrogen peroxide (H2O2). CDs with peroxidase-mimicking activity were prepared with a one-step hydrothermal method using L-histidine as an inexpensive precursor. CDs had bright blue fluorescence. Due to the pseudo-peroxidase activity, CDs catalyzed the oxidation of o-phenylenediamine (OPD) with H2O2 to generate 2,3-diaminophenolazine (DAP). The fluorescence resonance energy transfer (FRET) between CDs and DAP resulted in a decrease in the fluorescence of CDs and an increase in the fluorescence of DAP, leading to a ratiometric fluorescence system. The free radical trapping experiment was used to investigate the reactive oxygen radicals (ROS) in the catalytic process of CD nanozymes. The enzymatic parameters of CD nanozymes, including the Michaelis constant (K-m) and the maximum initial reaction velocities (V-max), were investigated. A good affinity for both OPD and H2O2 substrates was proven. Based on the FRET between CDs and OPD, a ratiometric fluorescence analysis of H2O2 was achieved and results ranged from 1 to 20 mu M and 20 to 200 mu M with a low limit of detection (LOD, 0.42 mu M). The detection of H2O2 in milk was also achieved.
引用
收藏
页数:17
相关论文
共 50 条
  • [31] Carbon quantum dots based ratiometric fluorescence probe for sensitive and selective detection of Cu2+ and glutathione
    Han, Zhu
    Nan, Danyang
    Yang, Huan
    Sun, Qianqian
    Pan, Shuang
    Liu, Hui
    Hu, Xiaoli
    SENSORS AND ACTUATORS B-CHEMICAL, 2019, 298
  • [32] A sensitive ratiometric fluorescent sensor based on carbon dots and CdTe quantum dots for visual detection of biogenic amines in food samples
    Yan, Jianfeng
    Fu, Quanbin
    Zhang, Shikai
    Liu, Yu
    Shi, Xianbao
    Hou, Juying
    Duan, Junling
    Ai, Shiyun
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2022, 282
  • [33] A ratiometric fluorescence sensor based on carbon quantum dots realized the quantitative and visual detection of Hg2+
    Liu, Yalei
    Su, Luyao
    Wang, Sui
    Guo, Zhiyong
    Hu, Yufang
    LUMINESCENCE, 2022, 37 (02) : 220 - 229
  • [34] Ratiometric fluorescence sensor based on chiral europium-doped carbon dots for specific and portable detection of tetracycline
    Liu, Min
    Wei, Shanshan
    Xie, Yuxin
    Su, Kaihua
    Yin, Xiangyu
    Song, Xuewei
    Hu, Kaixin
    Sun, Guoying
    Liu, Yibing
    SENSORS AND ACTUATORS B-CHEMICAL, 2025, 423
  • [35] Carbon Dots Fluorescence-Based Colorimetric Sensor for Sensitive Detection of Aluminum Ions with a Smartphone
    Wei, Wei
    Huang, Juan
    Gao, Wenli
    Lu, Xiangyang
    Shi, Xingbo
    CHEMOSENSORS, 2021, 9 (02) : 1 - 13
  • [36] A sensitive and selective BINOL based ratiometric fluorescence sensor for the detection of cyanide ions
    Munusamy, Sathishkumar
    Swaminathan, Sathish
    Jothi, Dhanapal
    Muralidharan, Vivek Panyam
    Iyer, Sathiyanarayanan Kulathu
    RSC ADVANCES, 2021, 11 (26) : 15656 - 15662
  • [37] Microwave-assisted fabrication of multicolor photoluminescent carbon dots as a ratiometric fluorescence sensor for iron ions
    Sun, Zhongqi
    Yang, Zhaoyu
    Zhao, Li
    Zhang, Yuheng
    Li, Yongqi
    Hou, Juan
    Ding, Lan
    NEW JOURNAL OF CHEMISTRY, 2019, 43 (02) : 853 - 861
  • [38] Sensitive fluorescence detection for hydrogen peroxide and glucose using biomass carbon dots: Dual-quenching mechanism insight
    Wu, Lei
    Pan, Wenyue
    Ye, Heng
    Liang, Ning
    Zhao, Longshan
    COLLOIDS AND SURFACES A-PHYSICOCHEMICAL AND ENGINEERING ASPECTS, 2022, 638
  • [39] Fluorescence switching sensor for sensitive detection of sinapine using carbon quantum dots
    Xiang, Xia
    Zhang, Zhen
    Han, Ling
    Huang, Fenghong
    Zheng, Mingming
    Tang, Hu
    Deng, Qianchun
    SENSORS AND ACTUATORS B-CHEMICAL, 2017, 241 : 482 - 488
  • [40] A ratiometric fluorescence probe based on carbon dots for discriminative and highly sensitive detection of acetylcholinesterase and butyrylcholinesterase in human whole blood
    Xu, Xiaoman
    Cen, Yao
    Xu, Guanhong
    Wei, Fangdi
    Shi, Menglan
    Hu, Qin
    BIOSENSORS & BIOELECTRONICS, 2019, 131 : 232 - 236