Lung texture in serial thoracic CT scans: Assessment of change introduced by image registration

被引:28
作者
Cunliffe, Alexandra R. [1 ]
Al-Hallaq, Hania A. [2 ]
Labby, Zacariah E. [1 ]
Pelizzari, Charles A. [2 ]
Straus, Christopher [1 ]
Sensakovic, William F. [1 ]
Ludwig, Michelle [1 ]
Armato, Samuel G., III [1 ]
机构
[1] Univ Chicago, Dept Radiol, Chicago, IL 60637 USA
[2] Univ Chicago, Dept Radiat & Cellular Oncol, Chicago, IL 60637 USA
基金
美国国家卫生研究院; 美国国家科学基金会;
关键词
texture analysis; image registration; lung; CT; DEFORMABLE REGISTRATION; NONRIGID REGISTRATION; COMPUTERIZED ANALYSIS; DISEASE; CLASSIFICATION; RADIOTHERAPY; ALGORITHM; DIAGNOSIS; HYBRID;
D O I
10.1118/1.4730505
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The aim of this study was to quantify the effect of four image registration methods on lung texture features extracted from serial computed tomography (CT) scans obtained from healthy human subjects. Methods: Two chest CT scans acquired at different time points were collected retrospectively for each of 27 patients. Following automated lung segmentation, each follow-up CT scan was registered to the baseline scan using four algorithms: (1) rigid, (2) affine, (3) B-splines deformable, and (4) demons deformable. The registration accuracy for each scan pair was evaluated by measuring the Euclidean distance between 150 identified landmarks. On average, 1432 spatially matched 32 x 32-pixel region-of-interest (ROT) pairs were automatically extracted from each scan pair. First-order, fractal, Fourier, Laws' filter, and gray-level co-occurrence matrix texture features were calculated in each ROI, for a total of 140 features. Agreement between baseline and follow-up scan ROT feature values was assessed by Bland-Altman analysis for each feature; the range spanned by the 95% limits of agreement of feature value differences was calculated and normalized by the average feature value to obtain the normalized range of agreement (nRoA). Features with small nRoA were considered "registration-stable." The normalized bias for each feature was calculated from the feature value differences between baseline and follow-up scans averaged across all ROIs in every patient. Because patients had "normal" chest CT scans, minimal change in texture feature values between scan pairs was anticipated, with the expectation of small bias and narrow limits of agreement. Results: Registration with demons reduced the Euclidean distance between landmarks such that only 9% of landmarks were separated by >= 1 mm, compared with rigid (98%), affine (95%), and B-splines (90%). Ninety-nine of the 140 (71%) features analyzed yielded nRoA > 50% for all registration methods, indicating that the majority of feature values were perturbed following registration. Nineteen of the features (14%) had nRoA < 15% following demons registration, indicating relative feature value stability. Student's t-tests showed that the nRoA of these 19 features was significantly larger when rigid, affine, or B-splines registration methods were used compared with demons registration. Demons registration yielded greater normalized bias in feature value change than B-splines registration, though this difference was not significant (p = 0.15). Conclusions: Demons registration provided higher spatial accuracy between matched anatomic landmarks in serial CT scans than rigid, affine, or B-splines algorithms. Texture feature changes calculated in healthy lung tissue from serial CT scans were smaller following demons registration compared with all other algorithms. Though registration altered the values of the majority of texture features, 19 features remained relatively stable after demons registration, indicating their potential for detecting pathologic change in serial CT scans. Combined use of accurate deformable registration using demons and texture analysis may allow for quantitative evaluation of local changes in lung tissue due to disease progression or treatment response. (C) 2012 American Association of Physicists in Medicine. [http://dx.doi.org/10.1118/1.4730505]
引用
收藏
页码:4679 / 4690
页数:12
相关论文
共 50 条
  • [41] Segmentation of Lungs with Interstitial Lung Disease in CT Scans: A TV-L1 Based Texture Analysis Approach
    Gill, Gurman
    Beichel, Reinhard R.
    ADVANCES IN VISUAL COMPUTING (ISVC 2014), PT 1, 2014, 8887 : 511 - 520
  • [42] Image Quality Measurement for Low-Dose Human Lung CT Scans
    Bognar, Gergo
    2015 38TH INTERNATIONAL CONFERENCE ON TELECOMMUNICATIONS AND SIGNAL PROCESSING (TSP), 2015, : 587 - 591
  • [43] Automatic registration of thoracic FDG-PET and CT for diagnosis and staging of lung cancer
    Asmuth, JC
    Moore, RH
    Bogoni, L
    Aquino, SL
    CARS 2002: COMPUTER ASSISTED RADIOLOGY AND SURGERY, PROCEEDINGS, 2002, : 1033 - 1033
  • [44] Effect of CAD on radiologists' detection of lung nodules on thoracic CT scans: Observer performance study
    Sahiner, Berkman
    Hadjiiski, Lubomir M.
    Chan, Heang-Ping
    Shi, Jiazheng
    Cascade, Philip N.
    Kazerooni, Ella A.
    Zhou, Chuan
    Wei, Jun
    Chughtai, Aamer R.
    Poopat, Chad
    Song, Thomas
    Nojkova, Jadranka S.
    Frank, Luba
    Attili, Anil
    MEDICAL IMAGING 2007: IMAGE PERCEPTION, OBSERVER PERFORMANCE, AND TECHNOLOGY ASSESSMENT, 2007, 6515
  • [45] Deformable image registration for contour propagation from CT to cone-beam CT scans in radiotherapy of prostate cancer
    Thor, Maria
    Petersen, Jorgen B. B.
    Bentzen, Lise
    Hoyer, Morten
    Muren, Ludvig Paul
    ACTA ONCOLOGICA, 2011, 50 (06) : 918 - 925
  • [46] Lung cancer detection from thoracic CT scans using an ensemble of deep learning models
    Gautam, Nandita
    Basu, Abhishek
    Sarkar, Ram
    NEURAL COMPUTING & APPLICATIONS, 2024, 36 (05) : 2459 - 2477
  • [47] Nonrigid Image Registration Method for Thoracic CT Images Using Vessel Structure Information
    Maeda, Shinya
    Kim, Hyoungseop
    Tan, Joo Kooi
    Ishikawa, Seiji
    Murakami, Seiichi
    Aoki, Takatoshi
    PROCEEDINGS 2012 IEEE INTERNATIONAL CONFERENCE ON SYSTEMS, MAN, AND CYBERNETICS (SMC), 2012, : 1407 - 1411
  • [48] Texture characteristic of CT image for lung parenchyma based on fractal dimension
    Chen, ZC
    Tang, F
    Zhou, ZY
    Jiang, DZ
    Jiang, Y
    PROCEEDINGS OF THE THIRD INTERNATIONAL SYMPOSIUM ON INSTRUMENTATION SCIENCE AND TECHNOLOGY, VOL 3, 2004, : 716 - 720
  • [49] Validation of nonrigid registration in pretreatment and follow-up PET/CT scans for quantification of tumor residue in lung cancer patients
    Spijkerman, Jolanda
    Fontanarosa, Davide
    Das, Marco
    van Elmpt, Wouter
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2014, 15 (04): : 240 - 250
  • [50] Technical Note: Density correction to improve CT number mapping in thoracic deformable image registration
    Yang, Jinzhong
    Zhang, Yongbin
    Zhang, Zijian
    Zhang, Lifei
    Batter, Peter
    Court, Laurence
    MEDICAL PHYSICS, 2019, 46 (05) : 2330 - 2336