Lung texture in serial thoracic CT scans: Assessment of change introduced by image registration

被引:28
作者
Cunliffe, Alexandra R. [1 ]
Al-Hallaq, Hania A. [2 ]
Labby, Zacariah E. [1 ]
Pelizzari, Charles A. [2 ]
Straus, Christopher [1 ]
Sensakovic, William F. [1 ]
Ludwig, Michelle [1 ]
Armato, Samuel G., III [1 ]
机构
[1] Univ Chicago, Dept Radiol, Chicago, IL 60637 USA
[2] Univ Chicago, Dept Radiat & Cellular Oncol, Chicago, IL 60637 USA
基金
美国国家卫生研究院; 美国国家科学基金会;
关键词
texture analysis; image registration; lung; CT; DEFORMABLE REGISTRATION; NONRIGID REGISTRATION; COMPUTERIZED ANALYSIS; DISEASE; CLASSIFICATION; RADIOTHERAPY; ALGORITHM; DIAGNOSIS; HYBRID;
D O I
10.1118/1.4730505
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The aim of this study was to quantify the effect of four image registration methods on lung texture features extracted from serial computed tomography (CT) scans obtained from healthy human subjects. Methods: Two chest CT scans acquired at different time points were collected retrospectively for each of 27 patients. Following automated lung segmentation, each follow-up CT scan was registered to the baseline scan using four algorithms: (1) rigid, (2) affine, (3) B-splines deformable, and (4) demons deformable. The registration accuracy for each scan pair was evaluated by measuring the Euclidean distance between 150 identified landmarks. On average, 1432 spatially matched 32 x 32-pixel region-of-interest (ROT) pairs were automatically extracted from each scan pair. First-order, fractal, Fourier, Laws' filter, and gray-level co-occurrence matrix texture features were calculated in each ROI, for a total of 140 features. Agreement between baseline and follow-up scan ROT feature values was assessed by Bland-Altman analysis for each feature; the range spanned by the 95% limits of agreement of feature value differences was calculated and normalized by the average feature value to obtain the normalized range of agreement (nRoA). Features with small nRoA were considered "registration-stable." The normalized bias for each feature was calculated from the feature value differences between baseline and follow-up scans averaged across all ROIs in every patient. Because patients had "normal" chest CT scans, minimal change in texture feature values between scan pairs was anticipated, with the expectation of small bias and narrow limits of agreement. Results: Registration with demons reduced the Euclidean distance between landmarks such that only 9% of landmarks were separated by >= 1 mm, compared with rigid (98%), affine (95%), and B-splines (90%). Ninety-nine of the 140 (71%) features analyzed yielded nRoA > 50% for all registration methods, indicating that the majority of feature values were perturbed following registration. Nineteen of the features (14%) had nRoA < 15% following demons registration, indicating relative feature value stability. Student's t-tests showed that the nRoA of these 19 features was significantly larger when rigid, affine, or B-splines registration methods were used compared with demons registration. Demons registration yielded greater normalized bias in feature value change than B-splines registration, though this difference was not significant (p = 0.15). Conclusions: Demons registration provided higher spatial accuracy between matched anatomic landmarks in serial CT scans than rigid, affine, or B-splines algorithms. Texture feature changes calculated in healthy lung tissue from serial CT scans were smaller following demons registration compared with all other algorithms. Though registration altered the values of the majority of texture features, 19 features remained relatively stable after demons registration, indicating their potential for detecting pathologic change in serial CT scans. Combined use of accurate deformable registration using demons and texture analysis may allow for quantitative evaluation of local changes in lung tissue due to disease progression or treatment response. (C) 2012 American Association of Physicists in Medicine. [http://dx.doi.org/10.1118/1.4730505]
引用
收藏
页码:4679 / 4690
页数:12
相关论文
共 50 条
  • [21] Introducing a novel sub-millimeter lung CT image registration error quantitation tool
    Boyle, Peter
    Naumann, Louise
    Lauria, Michael
    Miller, Claudia
    Andosca, Ryan
    Savjani, Ricky
    O'Connell, Dylan
    Moghanaki, Drew
    Barjaktarevic, Igor
    Goldin, Jonathan
    Low, Daniel A.
    MEDICAL PHYSICS, 2025, 52 (03) : 1601 - 1614
  • [22] Automated image quality assessment for chest CT scans
    Reeves, Anthony P.
    Xie, Yiting
    Liu, Shuang
    MEDICAL PHYSICS, 2018, 45 (02) : 561 - 578
  • [23] Nonlinear registration of serial coronary CT angiography (CCTA) for assessment of changes in atherosclerotic plaque
    Woo, Jonghye
    Dey, Damini
    Cheng, Victor Y.
    Hong, Byung-Woo
    Ramesh, Amit
    Sundaramoorthi, Ganesh
    Nakazato, Ryo
    Berman, Daniel S.
    Germano, Guido
    Kuo, C. -C. Jay
    Slomka, Piotr J.
    MEDICAL PHYSICS, 2010, 37 (02) : 885 - 896
  • [24] Registration accuracy and image quality of time averaged mid-position CT scans for liver SBRT
    Kruis, Matthijs F.
    van de Kamer, Jeroen B.
    Sonke, Jan-Jakob
    Jansen, Edwin P. M.
    van Herk, Marcel
    RADIOTHERAPY AND ONCOLOGY, 2013, 109 (03) : 404 - 408
  • [25] Improved B-spline image registration between exhale and inhale lung CT images based on intensity and gradient orientation information
    Nam, Woo Hyun
    Oh, Jihun
    Yi, Jonghyon
    Park, Yongsup
    Cho, Hansu
    Kim, Sukjin
    MEDICAL IMAGING 2016: IMAGE PROCESSING, 2016, 9784
  • [26] ASSESSMENT OF LUNG BIOMECHANICS IN COPD USING IMAGE REGISTRATION
    Pan, Yue
    Christensen, Gary E.
    Durumeric, Oguz C.
    Gerard, Sarah E.
    Bhatt, Surya P.
    Barr, R. Graham
    Hoffman, Eric A.
    Reinhardt, Joseph M.
    2020 IEEE 17TH INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI 2020), 2020, : 1891 - 1895
  • [27] Deep-learning-based deformable image registration of head CT and MRI scans
    Ratke, Alexander
    Darsht, Elena
    Heinzelmann, Feline
    Kroeninger, Kevin
    Timmermann, Beate
    Baeumer, Christian
    FRONTIERS IN PHYSICS, 2023, 11
  • [28] Open source deformable image registration system for treatment planning and recurrence CT scans
    Zukauskaite, Ruta
    Brink, Carsten
    Hansen, Christian Ronn
    Bertelsen, Anders
    Johansen, Jorgen
    Grau, Cai
    Eriksen, Jesper Grau
    STRAHLENTHERAPIE UND ONKOLOGIE, 2016, 192 (08) : 545 - 551
  • [29] Lung Respiratory Motion Estimation Based on Fast Kalman Filtering and 4D CT Image Registration
    Xue, Peng
    Fu, Yu
    Ji, Huizhong
    Cui, Wentao
    Dong, Enqing
    IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2021, 25 (06) : 2007 - 2017
  • [30] Uncertain prediction of deformable image registration on lung CT using multi-category features and supervised learning
    Zhou, Zhiyong
    Yin, Pengfei
    Liu, Yuhang
    Hu, Jisu
    Qian, Xusheng
    Chen, Guangqiang
    Hu, Chunhong
    Dai, Yakang
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2024, 62 (09) : 2669 - 2686