Dosimetric characteristics of intensity-modulated radiation therapy and RapidArc® therapy using a 3D N-isopropylacrylamide gel dosimeter

被引:2
作者
Yao, Chun-Hsu [1 ,2 ]
Tsai, Ting-Yu [3 ]
Hsieh, Bor-Tsung [4 ]
Tsang, Yuk-Wah [5 ]
Chiu, Chung-Yu [5 ]
Chao, His-Ya [5 ]
Chang, Yuan-Jen [6 ]
机构
[1] China Med Univ, Sch Chinese Med, Dept Biomed Imaging & Radiol Sci, 91 Hsueh Shih Rd, Taichung 40402, Taiwan
[2] Asia Univ, Dept Biomed Informat, 500 Liufeng Rd, Taichung 41354, Taiwan
[3] China Med Univ, Dept Biomed Imaging & Radiol Sci, 91 Hsueh Shih Rd, Taichung 40402, Taiwan
[4] Cent Taiwan Univ Sci & Technol, Dept Biomed Imaging & Radiol Sci, 666 Buzih Rd, Taichung, Taiwan
[5] Chiayi Christian Hosp, Ditmanson Med Fdn, Dept Radiat Oncol, 539 Zhongxiao Rd, Chiayi 60002, Taiwan
[6] Cent Taiwan Univ Sci & Technol, Dept Management Informat Syst, 666 Buzih Rd, Taichung 40601, Taiwan
来源
PROCEEDINGS OF THE 2015 INTERNATIONAL CONFERENCE ON APPLICATIONS OF NUCLEAR TECHNIQUES (CRETE15) | 2016年 / 44卷
关键词
NIPAM gel dosimeter; Optical CT; IMRT; RapidArc; OPTICAL-CT SCANNER; POLYMER GEL; DOSE DISTRIBUTIONS; VERIFICATION;
D O I
10.1142/S2010194516602210
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
This study aimed to investigate the dosimetric characteristics of intensity-modulated radiation therapy (IMRT) and RapidArc therapy by using 3D N-isopropylacrylamide (NIPAM) polymer gel. Optical computed tomography, specifically OCTOPUSTM-10X fast optical computed tomography scanner, was used as a readout tool. Two cylindrical acrylic phantoms (10 cm in diameter, 10 cm in height, and 3 mm in thickness) were filled with NIPAM gel and used for IMRT and RapidArc irradiation by using the Clinac iX treatment machine. The irradiation energies for IMRT and RapidArc (R) were set as 6 MV photons, but their irradiation angles and dose rates differed during irradiation. The irradiation angles of IMRT were 120 degrees, 155 degrees, 180 degrees, 215 degrees, and 245 degrees, and the dose rate was fixed at 400 cGy/min. RapidArc (R) rotated continuously during irradiation, and the dose rate varied from 330 cGy/min to 400 cGy/min. The pass rates were 98.02% and 97.48% for IMRT and RapidArc (R), respectively, and the rejected area appeared at the edge of the irradiated region. The isodose lines of IMRT and RapidArc (R) were consistent with those of TPS in most regions. Scattering and edge enhancement effects are main factors that cause dose inaccuracy in the edge region and reduced pass rates. Considering dose rate dependence, we used variable dose rates during irradiation with RapidArc (R). Results showed that the dose distribution of NIPAM gel was consistent with that of TPS. The pass rates were also the same for IMRT and RapidArc (R) irradiation. This study proposes a preliminary profile of dosimetric characteristics of IMRT and RapidArc (R) by using a NIPAM gel dosimeter.
引用
收藏
页数:9
相关论文
共 21 条
[1]  
Baldock C., 2006, Journal of Physics: Conference Series, V56, P14, DOI 10.1088/1742-6596/56/1/002
[2]   Polymer gel dosimetry [J].
Baldock, C. ;
De Deene, Y. ;
Doran, S. ;
Ibbott, G. ;
Jirasek, A. ;
Lepage, M. ;
McAuley, K. B. ;
Oldham, M. ;
Schreiner, L. J. .
PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (05) :R1-R63
[3]  
Ceberg S., 2009, J PHYS C SER, V164
[4]  
Chang Yaw-Wen, 2012, PLoS One, V7, pe38079, DOI [10.1371/journal.pone.0041362, 10.1371/journal.pone.0038079]
[5]   Characterization of long-term dose stability of N-isopropylacrylamide polymer gel dosimetry [J].
Chang, Y. J. ;
Chen, C. H. ;
Hsieh, B. T. .
JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2014, 301 (03) :765-780
[6]   Dose evaluation of an NIPAM polymer gel dosimeter using gamma index [J].
Chang, Yuan-Jen ;
Lin, Jing-Quan ;
Hsieh, Bor-Tsung ;
Yao, Chun-Hsu ;
Chen, Chin-Hsing .
RADIATION PHYSICS AND CHEMISTRY, 2014, 104 :180-187
[7]   A systematic approach to determine optimal composition of gel used in radiation therapy [J].
Chang, Yuan-Jen ;
Hsieh, Bor-Tsung ;
Liang, Ji-An .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 652 (01) :783-785
[8]   Polymer gels for magnetic resonance imaging of radiation dose distributions at normal room atmosphere [J].
Fong, PM ;
Keil, DC ;
Does, MD ;
Gore, JC .
PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (12) :3105-3113
[9]  
Hayashi N., 2014, J RAD RES, V1
[10]   A study on dose response of NIPAM-based dosimeter used in radiotherapy [J].
Hsieh, B. T. ;
Chang, Y. J. ;
Han, R. P. ;
Wu, J. ;
Hsieh, L. L. ;
Chang, C. J. .
JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2011, 290 (01) :141-148