Temporal and spatial evolution of temperature field of single freezing pipe in large velocity infiltration configuration

被引:18
|
作者
Wang, Bin [1 ,2 ]
Rong, Chuanxin [1 ,2 ]
Cheng, Hua [2 ]
Cai, Haibing [2 ]
Dong, Yanbin [2 ]
Yang, Fan [2 ]
机构
[1] Anhui Univ Sci & Technol, State Key Lab Min Response & Disaster Prevent & C, Hefei, Peoples R China
[2] Anhui Univ Sci & Technol, Sch Civil Engn & Architecture, Hefei, Peoples R China
基金
中国国家自然科学基金;
关键词
Artificial ground freezing method; Seepage; Hydrothermal coupling; Analytical solution; Steady-state temperature field; FROZEN SOIL WALL; HEAT-TRANSFER; MODEL; OPTIMIZATION; FLOW;
D O I
10.1016/j.coldregions.2020.103080
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
By accurately controlling the flow velocity and direction of the seepage field and fully considering the influence of the flow and heat-transfer boundary conditions, a large-scale, hydrothermal, coupled-physical-model test system was constructed. The temporal and spatial evolution of the temperature field of single freezing pipe in large velocity infiltration formation was studied by this system. The experimental results were analyzed based on the characteristics of heat conduction and convective heat transfer. The analysis results showed that when the seepage velocity v = 0, 3, 6 and 9 m/d, the time required for the freezing temperature field formed by single freezing pipe to enter the stabilization phase was 28 h, 36 h, 24 h and 20 h, respectively. And when the seepage velocity v = 3 m/d, the temperature drop rate of the frozen region decreased, however, after entering the stable freezing phase, the differences in final shape and extent of the frozen front compared to those of the no-flow state were smaller. When the seepage velocity v = 6 and 9 m/d, the temperature drop rate of the frozen region was further reduced, and the temperature of the upstream region was significantly higher than the downstream region. After entering the stable freezing phase, the extents of the upstream/side/downstream expansion of the freezing front were reduced by 72.27%/52.83%/27.73% and 76.89%/55.89%/39.07%, respectively. And the maximum value that the extended radius Rs could reach on both sides of the freezing pipe was 236/199/110/ 101 mm, for v = 0/3/6/9 m/d. Based on the results of model tests, an analytical expression of the steady-state temperature field of single freezing pipe under the action of seepage field was derived. The calculation results of the formulas showed that as the seepage velocity increased, the area of the single-pipe freezing zone decreased, the proportion of the low-temperature zone increased, and the average temperature of the temperature field decreased.
引用
收藏
页数:14
相关论文
共 50 条
  • [31] The spatial-temporal evolution of the electron density and temperature for a nanosecond microdischarge
    Huang, Bang-Dou
    Zhu, Xi-Ming
    Takashima, Keisuke
    Pu, Yi-Kang
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2013, 46 (46)
  • [32] Spatial and temporal distribution of surface water content in a large agricultural field
    Lascano, RJ
    Baumhardt, RL
    Hicks, SK
    Landivar, JA
    PROCEEDINGS OF THE FOURTH INTERNATIONAL CONFERENCE ON PRECISION AGRICULTURE, PTS A AND B, 1999, : 19 - 30
  • [33] Study on Temporal and Spatial Variation in Soil Temperature in Artificial Ground Freezing of Subway Cross Passage
    Zou, Baoping
    Hu, Bo
    Xia, Jianzhong
    Li, Xiaoquan
    Chen, Qizhi
    Kong, Bowen
    Ma, Jingyuan
    SUSTAINABILITY, 2023, 15 (04)
  • [34] Ponded infiltration in a grid of permanent single-ring infiltrometers: Spatial versus temporal variability
    Votrubova, Jana
    Dohnal, Michal
    Vogel, Tomas
    Tesar, Miroslav
    Jelinkova, Vladimira
    Cislerova, Milena
    JOURNAL OF HYDROLOGY AND HYDROMECHANICS, 2017, 65 (03) : 244 - 253
  • [35] Research of Spatial and Temporal Evolution Mechanism and Countermeasures of Haze Spatial Pattern in China: Visual Field Based on Dynamic Evolution and Spatial Agglomeration
    Tong, Xin
    Li, Xuesen
    Tong, Lin
    Chen, Kai
    ADVANCES IN METEOROLOGY, 2019, 2019
  • [36] Freezing Temperature Field of FSPR under Different Pipe Configurations: A Case Study in Gongbei Tunnel, China
    Duan, Yin
    Rong, Chuanxin
    Cheng, Hua
    Cai, Haibing
    Long, Wei
    ADVANCES IN CIVIL ENGINEERING, 2021, 2021
  • [37] Analytical Solution to Steady-state Temperature Field of Freeze-sealing Pipe-roof with Specific Freezing Pipe Arrangement
    管幕冻结特殊布管形式稳态温度场解析解
    2018, Chang'an University (31):
  • [38] Temperature field analysis of new pipe curtain freezing method in river embankment anti seepage reinforcement
    Zhou Y.
    Hu J.
    Xiong H.
    Ren J.
    Zhan J.
    Wang Z.
    Meitiandizhi Yu Kantan/Coal Geology and Exploration, 2022, 50 (05): : 110 - 117
  • [39] An Analytical Solution to Temperature Distribution of Single-Row-Piped Freezing with Different Pipe Surface Temperatures
    Hu Xiangdong
    Zhang Luoyu
    Han Yanguang
    ADVANCES IN CIVIL AND INDUSTRIAL ENGINEERING, PTS 1-4, 2013, 353-356 : 478 - 481
  • [40] An analytical solution to temperature distribution of single-row-piped freezing with different pipe surface temperatures
    Hu, Xiang Dong
    Zhang, Luo Yu
    Han, Yan Guang
    Applied Mechanics and Materials, 2013, 353-354 : 478 - 481