Refined methodology for implantation of a head fixation device and chronic recording chambers in non-human primates

被引:22
作者
Lanz, F. [1 ]
Lanz, X. [2 ,4 ]
Scherly, A. [4 ]
Moret, V. [1 ]
Gaillard, A. [1 ]
Gruner, P. [3 ]
Hoogewoud, H-M [5 ]
Belhaj-Saif, A. [1 ]
Loquet, G. [1 ]
Rouiller, E. M. [1 ]
机构
[1] Univ Fribourg, Fribourg Cognit Ctr, Unit Physiol, Dept Med, CH-1700 Fribourg, Switzerland
[2] Ecole Ingn, Dept Mecan, Fribourg, Switzerland
[3] Medicoat AG, Magenwil, Switzerland
[4] S D Scherly, La Roche, Switzerland
[5] Hop Cantonal Fribourg, Hop Fribourgeois HFR, Dept Radiol, Fribourg, Switzerland
关键词
Macaque monkey; Skull implants; Osseous-integration; Chronic brain electrophysiology; Hydroxyapatite; SUPPLEMENTARY MOTOR AREA; PURSUIT EYE-MOVEMENTS; GRASP PERFORMANCE; CORTEX; MONKEYS; RECOVERY; NEURONS; LESION;
D O I
10.1016/j.jneumeth.2013.07.015
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The present study was aimed at developing a new strategy to design and anchor custom-fitted implants, consisting of a head fixation device and a chronic recording chamber, on the skull of adult macaque monkeys. This was done without the use of dental resin or orthopedic cement, as these modes of fixation exert a detrimental effect on the bone. The implants were made of titanium or tekapeek and anchored to the skull with titanium screws. Two adult macaque monkeys were initially implanted with the head fixation device several months previous to electrophysiological investigation, to allow optimal osseous-integration, including growth of the bone above the implant's footplate. In a second step, the chronic recording chamber was implanted above the brain region of interest. The present study proposes two original approaches for both implants. First, based on a CT scan of the monkey, a plastic replicate of the skull was obtained in the form of a 3D print, used to accurately shape and position the two implants. This would ensure a perfect match with the skull surface. Second, the part of the implants in contact with the bone was coated with hydroxyapatite, presenting chemical similarity to natural bone, thus promoting excellent osseous-integration. The longevity of the implants used here was 4 years for the head fixation device and 1.5 years for the chronic chamber. There were no adverse events and daily care was easy. This is clear evidence that the present implanting strategy was successful and provokes less discomfort to the animals. (C) 2013 The Authors. Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:262 / 270
页数:9
相关论文
共 25 条
[1]   A biocompatible titanium headpost for stabilizing behaving monkeys [J].
Adams, Daniel L. ;
Economides, John R. ;
Jocson, Cristina M. ;
Horton, Jonathan C. .
JOURNAL OF NEUROPHYSIOLOGY, 2007, 98 (02) :993-1001
[2]   A watertight acrylic-free titanium recording chamber for electrophysiology in behaving monkeys [J].
Adams, Daniel L. ;
Economides, John R. ;
Jocson, Cristina M. ;
Parker, John M. ;
Horton, Jonathan C. .
JOURNAL OF NEUROPHYSIOLOGY, 2011, 106 (03) :1581-1590
[3]   OSSEOINTEGRATION OF BONE IMPLANTS - A REVIEW OF AN ALTERNATIVE MODE OF FIXATION [J].
ALBREKTSSON, T ;
ALBREKTSSON, B .
ACTA ORTHOPAEDICA SCANDINAVICA, 1987, 58 (05) :567-577
[4]   INCREASE OF STABILITY IN EXTERNAL FRACTURE FIXATION BY HYDROXYAPATITE-COATED BONE SCREWS [J].
AUGAT, P ;
CLAES, L ;
HANSELMANN, KF ;
SUGER, G ;
FLEISCHMANN, W .
JOURNAL OF APPLIED BIOMATERIALS, 1995, 6 (02) :99-104
[5]   The use of titanium implants and prosthodontic techniques in the preparation of non-human primates for long-term neuronal recording studies [J].
Betelak, KF ;
Margiotti, EA ;
Wohlford, ME ;
Suzuki, DA .
JOURNAL OF NEUROSCIENCE METHODS, 2001, 112 (01) :9-20
[6]  
BRANEMARK P I, 1969, Scandinavian Journal of Plastic and Reconstructive Surgery, V3, P81
[7]   Apparent motion produces multiple deficits in visually guided smooth pursuit eye movements of monkeys [J].
Churchland, MM ;
Lisberger, SG .
JOURNAL OF NEUROPHYSIOLOGY, 2000, 84 (01) :216-235
[8]   HYDROXYLAPATITE COATING OF POROUS IMPLANTS IMPROVES BONE INGROWTH AND INTERFACE ATTACHMENT STRENGTH [J].
COOK, SD ;
THOMAS, KA ;
DALTON, JE ;
VOLKMAN, TK ;
WHITECLOUD, TS ;
KAY, JF .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1992, 26 (08) :989-1001
[9]  
DEREZENDE MLR, 1993, J MATER SCI-MATER M, V4, P233
[10]   Single-unit responses in the auditory cortex of monkeys performing a conditional acousticomotor task [J].
Durif, C ;
Jouffrais, C ;
Rouiller, EM .
EXPERIMENTAL BRAIN RESEARCH, 2003, 153 (04) :614-627