Reaction times and the decision-making process in endoscopic surgery - An experimental study

被引:23
作者
Zheng, B [1 ]
Janmohamed, Z [1 ]
MacKenzie, CL [1 ]
机构
[1] Simon Fraser Univ, Sch Kinesiol, Burnaby, BC V5A 1S6, Canada
来源
SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES | 2003年 / 17卷 / 09期
关键词
endoscopic decision making; sensorimotor integration; task complexity; surgical training; surgical skills; ergonomics;
D O I
10.1007/s00464-002-8759-0
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: There are times during endoscopic procedures when the displayed surgical field does not align with the actual field due to rotation of the camera. The surgeon's performance may deteriorate under this situation. However, the effects of misalignment on the decision-making processes during endoscopic procedures have not been fully explored. The present study addresses this problem and suggests a technique that may be used to alleviate it. Methods: Two experiments were completed in a mock endoscopic surgical setup where the image of the work plane inside the training box was either projected on a vertical monitor placed at eye level or superimposed over the training box by means of a half-silvered mirror. The work plane consisted of a start plate and four target plates. The experimenter varied the number of choices of target location among one, two, and four target choices. Rotating the camera about its longitudinal axis misaligned the displayed and the actual work plane. There were two experiments that differed in task difficulty. The task in experiment I was to touch the target plate, whereas the task in experiment 2 was to reach, grasp, and transport the object from the target to the start plate. Results: Experiment I showed that reaction time in creased with the number of the choices for a touch task, in accordance with the Hick-Hyman law. Using a grasp-and-transport task, experiment 2 replicated experiment I and extended the results to show that the use of a superimposed image display facilitated the decision-making process, leading to shorter reaction times compared to the vertical image display. Discussion: During endoscopic procedures, the surgeon needs to translate indirect perceptions to instrument-mediated actions by "mapping" them through sensorimotor integration. The superimposed image alleviates the mental load of spatial transformations by reducing the difficulty of the required sensorimotor mapping. These findings have important implications for the design of high-quality superimposed display technologies.
引用
收藏
页码:1475 / 1480
页数:6
相关论文
共 17 条
[1]   Ergonomic problems associated with laparoscopic surgery [J].
Berguer, R ;
Forkey, DL ;
Smith, WD .
SURGICAL ENDOSCOPY-ULTRASOUND AND INTERVENTIONAL TECHNIQUES, 1999, 13 (05) :466-468
[2]   Performing laparoscopic surgery is significantly more stressful for the surgeon than open surgery [J].
Berguer, R ;
Smith, WD ;
Chung, YH .
SURGICAL ENDOSCOPY-ULTRASOUND AND INTERVENTIONAL TECHNIQUES, 2001, 15 (10) :1204-1207
[3]  
Breedveld P, 2001, MINIM INVASIV THER, V10, P155
[4]   Methods for improving performance under reverse alignment conditions during endoscopic surgery [J].
Cresswell, AB ;
Macmillan, AIM ;
Hanna, GB ;
Cuschieri, A .
SURGICAL ENDOSCOPY-ULTRASOUND AND INTERVENTIONAL TECHNIQUES, 1999, 13 (06) :591-594
[5]  
CUSCHIERI A, 1995, SEMIN LAPAROSC SURG, V2, P209
[6]   An ergonomic analysis of the fulcrum effect in the acquisition of endoscopic skills [J].
Gallagher, AG ;
McClure, N ;
McGuigan, J ;
Ritchie, K ;
Sheehy, NP .
ENDOSCOPY, 1998, 30 (07) :617-620
[7]  
GRAHAM ED, 1995, P C HUM FACT COMP SY, P314
[8]  
GRAHAM ED, 1996, P C HUM FACT COMP SY, P292
[9]   Task performance in endoscopic surgery is influenced by location of the image display [J].
Hanna, GB ;
Shimi, SM ;
Cuschieri, A .
ANNALS OF SURGERY, 1998, 227 (04) :481-484
[10]  
HANNA GB, 1997, BRIT J SURG, V84, P1406