Effect of simulated inflammatory conditions and potential on dissolution and surface oxide of CoCrMo alloy: In situ electrochemical atomic force microscopy study

被引:30
|
作者
Liu, Yangping [1 ,2 ]
Gilbert, Jeremy L. [1 ,2 ,3 ,4 ]
机构
[1] Syracuse Univ, Syracuse Biomat Inst, Syracuse, NY 13244 USA
[2] Syracuse Univ, Dept Biomed & Chem Engn, Syracuse, NY 13244 USA
[3] Clemson Univ, Dept Bioengn, Clemson, SC 29634 USA
[4] Med Univ South Carolina, Dept Orthopaed, Charleston, SC 29425 USA
关键词
CoCrMo alloy; Oxide film; Atomic force microscopy; Corrosion; Inflammation; CELL-INDUCED CORROSION; COMMERCIALLY PURE TITANIUM; BIOLOGICAL CONDITIONS; FENTON CHEMISTRY; BEHAVIOR; IMPEDANCE; AFM; METAL; ARTHROPLASTY; OSTEOCLASTS;
D O I
10.1016/j.electacta.2017.12.151
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
Inflammation may develop in association with implantation of hip replacements and the inflammatory state of the local body fluids may affect the corrosion of metallic biomaterials like CoCrMo alloy. In this study CoCrMo alloy surfaces were imaged using in situ electrochemical atomic force microscopy (ECAFM) to evaluate oxide film morphology and surface dissolution while immersed in phosphate buffered saline (PBS) solution or simulated inflammatory (SI) solutions across a range of potentials. The SI solution explored here consisted of a 30 mM hydrogen peroxide (H2O2) modified PBS solution. Analysis of ECAFM images, surface roughness and potentiostatic polarization current density data exhibited a correlated relationship between surface oxide morphology, loss of passivity and electrochemical behavior CoCrMo alloy. ECAFM results showed that the presence of H2O2 altered oxide film behavior, leading to positive shifts of open circuit potential (OCP) to 0.32 V (vs Ag/AgCl), higher current density and significantly altered oxide film topography compared to PBS only case. Surface morphology, surface roughness (R-a) and current density exhibited strong potential- and time-dependent behaviors. Significant surface oxide formation on alloy and carbides were observed, followed by dissolution of CoCrMo alloy as potentials were increased above 0.5 V. Carbide boundaries and metal grain boundaries were preferential sites for oxide dissolution at transpassive potential ranges. Formation and evolution of new oxides were directly imaged at 0.65 V in PBS solution. New oxides formed and covered the surface in 10 min at 0.65 V. However, they were less protective compared to the passive oxide films at OCP condition. Simulated inflammatory solutions raise alter corrosion behavior of CoCrMo alloys. (C) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:252 / 263
页数:12
相关论文
共 50 条
  • [41] In situ observation of the surface processes involved in dissolution from the cleavage surface of calcite in aqueous solution using combined scanning electrochemical-atomic force microscopy (SECM-AFM)
    Jones, CE
    Unwin, PR
    Macpherson, JV
    CHEMPHYSCHEM, 2003, 4 (02) : 139 - 146
  • [42] Anodic dissolution growth of metal-organic framework HKUST-1 monitored via in situ electrochemical atomic force microscopy
    Worrall, Stephen D.
    Bissett, Mark A.
    Attfield, Martin P.
    Dryfe, Robert A. W.
    CRYSTENGCOMM, 2018, 20 (31): : 4421 - 4427
  • [43] Dynamics of Nucleic Acid/Cationic Polymer Complexation and Disassembly Under Biologically Simulated Conditions Using In Situ Atomic Force Microscopy
    Shim, Min Suk
    Wang, Xi
    Ragan, Regina
    Kwon, Young Jik
    MICROSCOPY RESEARCH AND TECHNIQUE, 2010, 73 (09) : 845 - 856
  • [44] IN-SITU OBSERVATION OF THE ELECTROCHEMICAL HG/AU AMALGAM PROCESS ON AN AU ELECTRODE SURFACE BY ATOMIC-FORCE MICROSCOPY
    YANG, XM
    TONAMI, K
    NAGAHARA, LA
    HASHIMOTO, K
    WEI, Y
    FUJISHIMA, A
    SURFACE SCIENCE, 1994, 319 (1-2) : L17 - L22
  • [45] Use of in situ electrochemical atomic force microscopy (EC-AFM) to monitor cathode surface reaction in organic electrolyte
    Vidu, R
    Quinlan, FT
    Stroeve, P
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2002, 41 (25) : 6546 - 6554
  • [46] Atomic force microscopy study of oscillatory surface roughening in anodic dissolution of sputter-deposited nickel films
    Saitou, M
    Makabe, A
    Tomoyose, T
    JOURNAL OF CHEMICAL PHYSICS, 2000, 113 (06): : 2397 - 2399
  • [47] IN-SITU OBSERVATION OF THE AU-HG ALLOY FORMATION ON A GOLD ELECTRODE SURFACE BY ATOMIC-FORCE MICROSCOPY
    YANG, XM
    TONAMI, K
    NAGAHARA, LA
    HASHIMOTO, K
    WEI, Y
    FUJISHIMA, A
    CHEMISTRY LETTERS, 1994, (11) : 2059 - 2062
  • [48] Electrochemical and morphological study of the effect of polymerization conditions on poly(tetrathiophene) with emphasis on carbon fiber microelectrodes: A cyclic voltammetry and atomic force microscopy study
    Sarac, AS
    Evans, U
    Serantoni, M
    Cunnane, VJ
    CARBON, 2003, 41 (14) : 2725 - 2730
  • [49] Development of in-situ atomic force microscopy for study of ion beam interaction with biological cell surface
    Sangyuenyongpipat, S
    Vilaithong, T
    Yu, LD
    Yimnirun, R
    Singjai, P
    Brown, IG
    PARTICLE BEAMS & PLASMA INTERACTION ON MATERIALS AND ION & PLASMA SURFACE FINISHING 2004, 2005, 107 : 47 - 50
  • [50] Effect of the electrosynthesis method on the surface morphology of the polypyrrole film -: An atomic force microscopy study
    Hernández-Pérez, T
    Morales, M
    Batina, N
    Salmón, M
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2001, 148 (05) : C369 - C375