Evaluation of a rapid method for the simultaneous quantification of ribavirin, sofosbuvir and its metabolite in rat plasma by UPLC-MS/MS

被引:57
作者
Shi, Xiaojun [1 ]
Zhu, Dedong [1 ]
Lou, Jie [2 ]
Zhu, Bo [3 ]
Hu, Ai-rong [1 ]
Gan, Dongmei [4 ]
机构
[1] Ningbo 2 Hosp, Dept Hepatopathy, Ningbo 315000, Zhejiang, Peoples R China
[2] Ningbo 2 Hosp, Digest Dept, Ningbo 315000, Zhejiang, Peoples R China
[3] Ningbo 2 Hosp, Pharmaceut Preparat Sect, Ningbo 315000, Zhejiang, Peoples R China
[4] Ningbo Women & Childrens Hosp, Dept Paediat, Ningbo 315000, Zhejiang, Peoples R China
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2015年 / 1002卷
关键词
Ribavirin; Sofosbuvir; GS-331007; UPLC-MS/MS; Plasma; Pharmacokinetics; CHRONIC HEPATITIS-C; LC-MS/MS; PLUS RIBAVIRIN; OPEN-LABEL; QUANTITATION; VALIDATION; INFECTION; INHIBITOR; VIRUS; SERUM;
D O I
10.1016/j.jchromb.2015.08.038
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A rapid and sensitive ultra performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) method for the determination of ribavirin, sofosbuvir and its metabolite GS-331007 in rat plasma was established. The analytes and the internal standard (midazolam) were separated on an Acquity UPLC BEH C18 chromatography column (2.1 mm x 50 mm, 1.7 mu m) using gradient elution with a mobile phase of acetonitrile and 0.1% formic acid in water at a flow rate of 0.4 mL/min. The detection was performed on a triple quadrupole tandem mass spectrometer by multiple reaction monitoring (MRM) mode to monitor the precursor-to-product ion transitions of m/z 245.1 -> 113.1 for ribavirin, m/z 530.3 -> 243.1 for sofosbuvir, m/z 261.5 -> 113.1 for GS-331007 and m/z 326.2 -> 291.1 for midazolam (IS) using a positive electrospray ionization interface. The method was validated over a concentration range of 5-1000 ng/mL for ribavirin, 10-2000 ng/mL for sofosbuvir and 10-2000 ng/mL for GS-331007. Total time for each chromatograph was 3.0 min. The intra- and inter-day precision and accuracy of the quality control samples at low, medium, and high concentration levels exhibited relative standard deviations (RSD) <10.0% and the accuracy values ranged from -10.6% to 11.6%. The method was successfully applied to a pharmacokinetic study of ribavirin, sofosbuvir and GS-331007 in rats. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:353 / 357
页数:5
相关论文
共 22 条
[1]  
[Anonymous], 2001, Guidance for Industry Bioanalytical Method Validation
[2]  
Cholongitas E, 2014, ANN GASTROENTEROL, V27, P331
[3]   Sofosbuvir and Ribavirin Prevent Recurrence of HCV Infection After Liver Transplantation: An Open-Label Study [J].
Curry, Michael P. ;
Forns, Xavier ;
Chung, Raymond T. ;
Terrault, Norah A. ;
Brown, Robert, Jr. ;
Fenkel, Jonathan M. ;
Gordon, Fredric ;
O'Leary, Jacqueline ;
Kuo, Alexander ;
Schiano, Thomas ;
Everson, Gregory ;
Schiff, Eugene ;
Befeler, Alex ;
Gane, Edward ;
Saab, Sammy ;
McHutchison, John G. ;
Subramanian, G. Mani ;
Symonds, William T. ;
Denning, Jill ;
McNair, Lindsay ;
Arterburn, Sarah ;
Svarovskaia, Evguenia ;
Moonka, Dilip ;
Afdhal, Nezam .
GASTROENTEROLOGY, 2015, 148 (01) :100-U519
[4]   Validation of liquid/liquid extraction method coupled with HPLC-UV for measurement of ribavirin plasma levels in HCV-positive patients [J].
D'Avolio, A ;
Ibañez, A ;
Sciandra, M ;
Siccardi, M ;
de Requena, DG ;
Bonora, S ;
Di Perri, G .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2006, 835 (1-2) :127-130
[5]   LC-MS/MS quantitation of ribavirin in serum and identification of endogenous isobaric interferences [J].
Danso, Darlington ;
Langman, Loralie J. ;
Snozek, Christine L. H. .
CLINICA CHIMICA ACTA, 2011, 412 (23-24) :2332-2335
[6]   Quantitation of ribavirin in human plasma and red blood cells using LC-MS/MS [J].
Ferreiros, N. ;
Labocha, S. ;
El-Duweik, J. ;
Schlecker, C. ;
Loetsch, J. ;
Geisslinger, G. .
JOURNAL OF SEPARATION SCIENCE, 2014, 37 (05) :476-483
[7]   Nucleotide Polymerase Inhibitor Sofosbuvir plus Ribavirin for Hepatitis C [J].
Gane, Edward J. ;
Stedman, Catherine A. ;
Hyland, Robert H. ;
Ding, Xiao ;
Svarovskaia, Evguenia ;
Symonds, William T. ;
Hindes, Robert G. ;
Berrey, M. Michelle .
NEW ENGLAND JOURNAL OF MEDICINE, 2013, 368 (01) :34-44
[8]   Stability-Indicating HPLC-DAD Determination of Ribavirin in Capsules and Plasma [J].
Haggag, Rim Said ;
Belal, Said Fathalla ;
Hewala, Ismail Ibrahim ;
El Rouby, Ola Ahmed .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2014, 52 (06) :493-500
[9]   Sofosbuvir: A Review of its Use in Patients with Chronic Hepatitis C [J].
Keating, Gillian M. .
DRUGS, 2014, 74 (10) :1127-1146
[10]   Sofosbuvir: First Global Approval [J].
Keating, Gillian M. ;
Vaidya, Asha .
DRUGS, 2014, 74 (02) :273-282