Patient perception and acceptability of multidose dry powder inhalers:: A Randomized crossover comparison of Diskus/Accuhaler with Turbuhaler

被引:60
作者
Serra-Batlles, J [1 ]
Plaza, V [1 ]
Badiola, C [1 ]
Morejón, E [1 ]
机构
[1] Hosp Gen Vic, Serv Pneumol, E-08500 Barcelona, Spain
来源
JOURNAL OF AEROSOL MEDICINE-DEPOSITION CLEARANCE AND EFFECTS IN THE LUNG | 2002年 / 15卷 / 01期
关键词
asthma; chronic obstructive pulmonary disease; inhalers; powder inhalers; Diskus/Accuhaler; Turbuhaler; inhaled drug therapy;
D O I
10.1089/08942680252908584
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
This study was designed to provide information on correct use and preference to features and device handling of two multidose dry powder inhalers, the Diskus/Accuhaler(R) and the Turbuhaler(R). A total of 169 powder-naive patients (mean age 40 years) with asthma or chronic obstructive pulmonary disease (COPD) were enrolled in a randomized crossover comparison of both inhalers. An effective use of either inhaler was assessed before (leaflet only) and after inhaler education. Ease of use especially during an attack and the presence of a dose counter were regarded as the most important features for an ideal inhaler. The percentage of correct handling maneuvers and the percentage of patients achieving 100% of correct maneuvers increased significantly (p < 0.001) after inhaler education in both devices, but percentage of correct use after the intervention was significantly higher for the Diskus/Accuhaler (92.6%) than for the Turbuhaler (89.8%; P = 0.036). Overall 60% of patients thought the Diskus/Accuhaler was preferable to the Turbuhaler (p < 0.001). The main reasons given were presence of a dose counter, perceived ease of use including ease of learning to use, design, and attached cover. Among those who preferred the Turbuhaler device, the main reason cited was small size, discreetness, and ease of holding. In the multivariate analysis, inhaler education (p = 0.005) and education level (p = 0.009) were significantly associated with the percentage of correct maneuvers. Age, sex, or tested inhaler showed no effect on appropriateness of the inhalation technique.
引用
收藏
页码:59 / 64
页数:6
相关论文
共 11 条
[1]  
BRINDLEY A, 1995, PHARM TECH EUR, V7, P14
[2]  
CHAPMAN KR, 1995, J AEROSOL MED, V8, pS27
[3]  
CONNOLLY A, 1995, EUR J CLIN RES, V7, P15
[4]   THE DISKUS(TM) - A NEW MULTIDOSE POWDER DEVICE - EFFICACY AND COMPARISON WITH TURBUHALER(TM) [J].
FULLER, R .
JOURNAL OF AEROSOL MEDICINE-DEPOSITION CLEARANCE AND EFFECTS IN THE LUNG, 1995, 8 :S11-S17
[5]  
LANGDON CG, 1994, BR J CLIN RES, V5, P85
[6]   A 1-year comparison of Turbuhaler vs pressurized metered-dose inhaler in asthmatic patients [J].
Pauwels, RA ;
Hargreave, FE ;
Camus, P ;
Bukoski, M ;
Stahl, E .
CHEST, 1996, 110 (01) :53-57
[7]  
PERSSON G, 1988, EUR RESPIR J, V1, P681
[8]  
Schlaeppi M, 1996, BRIT J CLIN PRACT, V50, P14
[9]   Comparison of a new multidose powder inhaler (Diskus®/Accuhaler®) and the Turbuhaler® regarding preference and ease of use [J].
van der Palen, J ;
Klein, JJ ;
Schildkamp, AM .
JOURNAL OF ASTHMA, 1998, 35 (02) :147-152
[10]   Therapeutic equivalence and acceptability of two multidose powder inhalers in the treatment of asthma [J].
Wettengel, R ;
Laurikainen, K ;
Silvasti, M ;
Toivanen, P ;
Sauter, K .
RESPIRATION, 2000, 67 (01) :77-82