Effective dose from cone beam CT examinations in dentistry

被引:241
作者
Roberts, J. A. [1 ]
Drage, N. A. [2 ]
Davies, J. [3 ]
Thomas, D. W. [1 ]
机构
[1] Velindre NHS Trust, Dept Med Phys, Velindre Canc Ctr, Cardiff, S Glam, Wales
[2] Univ Dent Hosp, Cardiff & Vale NHS Trust, Dept Dent Radiol, Cardiff, S Glam, Wales
[3] Guys Hosp, Dept Dent Radiol Imaging, London SE1 9RT, England
关键词
DIGITAL VOLUME TOMOGRAPHY; COMPUTED-TOMOGRAPHY; ORTHOGNATHIC SURGERY; DOSIMETRY; DEVICES;
D O I
10.1259/bjr/31419627
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Cone beam CT (CBCT) is becoming an increasingly utilized imaging modality for dental examinations in the UK. Previous studies have presented little information on patient dose for the range of fields of view (FOVs) that can be utilized. The purpose of the study was therefore to calculate the effective dose delivered to the patient during a selection of CBCT examinations performed in dentistry. in particular, the i-CAT CBCT scanner was investigated for several imaging protocols commonly used in clinical practice. A Rando phantom containing thermoluminescent dosemeters was scanned. Using both the 1990 and recently approved 2007 International Commission on Radiological Protection recommended tissue weighting factors, effective doses were calculated. The doses (E(1990), E(2007)) were: full FOV head (92.8 mu Sv, 206.2 mu Sv); 13 cm scan of the jaws (39.5 mu Sv, 133.9 mu Sv); 6 cm high-resolution mandible (47.2 mu Sv, 188.5 mu Sv); 6 cm high-resolution maxilla (18.5 mu Sv, 93.3 mu Sv); 6 cm standard mandible (23.9 mu Sv, 96.2 mu Sv); and 6 cm standard maxilla (9.7 mu Sv, 58.9 mu Sv). The doses from CBCT are low compared with conventional CT but significantly higher than conventional dental radiography techniques.
引用
收藏
页码:35 / 40
页数:6
相关论文
共 27 条
  • [1] [Anonymous], 2003, ORTHOD CRANIFOC R S1, DOI DOI 10.1007/S13181-011-0207-X
  • [2] [Anonymous], 1991, Annals of the ICRP, V21
  • [3] Superimposition of 3D cone-beam CT models of orthognathic surgery patients
    Cevidanes, LHS
    Bailey, LJ
    Tucker, GR
    Styner, MA
    Mol, A
    Phillips, CL
    Proffit, WR
    Turvey, T
    [J]. DENTOMAXILLOFACIAL RADIOLOGY, 2005, 34 (06) : 369 - 375
  • [4] Comparison of relative mandibular growth vectors with high-resolution 3-dimensional imaging
    Cevidanes, LHS
    Franco, AA
    Gerig, G
    Proffit, WR
    Slice, DE
    Enlow, DH
    Lederman, HM
    Amorim, L
    Scanavini, MA
    Vigorito, JW
    [J]. AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2005, 128 (01) : 27 - 34
  • [5] Three-dimensional cone-beam computed tomography for assessment of mandibular changes after orthognathic surgery
    Cevidanes, Lucia H. S.
    Bailey, L'Tanya J.
    Tucker, Scott F.
    Styner, Martin A.
    Mol, Andre
    Phillips, Ceib L.
    Proffit, William R.
    Turvey, Timothy
    [J]. AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2007, 131 (01) : 44 - 50
  • [6] State-of-the-art on cone beam CT imaging for preoperative planning of implant placement
    Guerrero, ME
    Jacobs, R
    Loubele, M
    Schutyser, F
    Suetens, P
    van Steenberghe, D
    [J]. CLINICAL ORAL INVESTIGATIONS, 2006, 10 (01) : 1 - 7
  • [7] Postoperative imaging of zygomaticomaxillary complex fractures using digital volume tomography
    Heiland, M
    Schulze, DK
    Rother, U
    Schmelzle, R
    [J]. JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2004, 62 (11) : 1387 - 1391
  • [8] Hiles P, 2005, 91 IPEM
  • [9] Cone-beam computed tomography in orthodontics: Benefits and limitations; [Die Digitale Volumentomographie in der Kieferorthopädie: Möglichkeiten und Grenzen]
    Holberg C.
    Steinhäuser S.
    Geis P.
    Rudzki-Janson I.
    [J]. Journal of Orofacial Orthopedics / Fortschritte der Kieferorthopädie, 2005, 66 (6): : 434 - 444
  • [10] International Commission on Radiation Protection, 2007, ANN ICRP, V37