Critical heat flux in uniformly heated vertical tubes

被引:27
作者
Cheng, X [1 ]
Erbacher, FJ [1 ]
Muller, U [1 ]
Pang, FG [1 ]
机构
[1] HARBIN ENGN UNIV,DEPT POWER ENGN,HARBIN,PEOPLES R CHINA
关键词
D O I
10.1016/S0017-9310(96)00344-4
中图分类号
O414.1 [热力学];
学科分类号
摘要
Experimental investigations on critical heat Aux have been performed in circular tubes of different diameters ranging from 2 to 16 mm. The model fluid Freon-12 was used as working fluid due to its low latent heat, low critical pressure and well-known properties. About 1700 data points have been obtained in a large range of parameters: pressure 1.0-3.0 MPa, mass flux 1.0-6.0 Mg m(-2) s(-1) and exit steam quality -0.75 to +0.59. It was found that the present rest results coincide well with the data sets available in the literature. A very good agreement between the test data in the 8 mm diameter tube and the CHF look-up table shows that the test results in Freon-12 can be well transferred to water conditions by using the Ahmad fluid-to-fluid scaling law. The experimental data reveal that the effect of the tube diameter on CHF cannot be described by the equations or models available in the literature with sufficient accuracy. (C) 1997 Elsevier Science Ltd.
引用
收藏
页码:2929 / 2939
页数:11
相关论文
共 21 条
[12]   CRITICAL HEAT-FLUX [J].
KATTO, Y .
INTERNATIONAL JOURNAL OF MULTIPHASE FLOW, 1994, 20 :53-90
[13]  
KIRILLOV PL, 1995, P NURETH 7 C NEW YOR, P2558
[14]  
KIRILLOV PL, 1989, P NURETH 4 C KARLSR, P103
[15]  
MULLERMENZEL T, 1987, NUCLEAR ENG DESIGN 9, P265
[17]  
STEVENS GF, 1964, AEEWR321 AT EN EST
[18]  
Tong L. S., 1972, 72HT54 ASME
[19]   PREDICTION OF CRITICAL HEAT-FLUX IN FLOW BOILING AT LOW QUALITIES [J].
WEISMAN, J ;
PEI, BS .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1983, 26 (10) :1463-1477
[20]  
*WORK PART HEAT MA, 1977, THERM ENG, V23, P77