Preparation of a portable point-of-care in vitro diagnostic system, for quantification of canine C-reactive protein, based on a magnetic two-site immunoassay

被引:11
作者
Ibraimi, Filiz [1 ,2 ]
Ekberg, Bjorn [1 ]
Kriz, Dario [3 ]
Danielsson, Gertrud [4 ]
Bulow, Leif [2 ]
机构
[1] LifeAssays AB, S-22370 Lund, Sweden
[2] Lund Univ, Dept Pure & Appl Biochem, S-22100 Lund, Sweden
[3] European Inst Sci, S-22370 Lund, Sweden
[4] Malmoe Anim Hosp, S-21363 Malmo, Sweden
关键词
Magnetic permeability; Superparamagnetic nanoparticles; Two-site immunoassay; Canine C-reactive protein; Point-of-care; PERMEABILITY DETECTION; KINETICS; DEXTRAN; ELISA; SERUM; DOGS;
D O I
10.1007/s00216-013-7032-9
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In this study, characterization of the binding kinetics and optimization of a magnetic permeability based point-of-care (POC) immunoassay system for quantification of canine C-reactive protein (cCRP) is described. The reagent is based on a two-site heterogeneous immunoassay system utilizing conjugated superparamagnetic nanoparticles (SPION) and silica particles, both particles carrying covalently linked antibodies directed to the cCRP analyte. Detection is carried out using a magnetic permeability-based small instrument, adjusted in order to apply it in a POC setting near the patients. The kinetic parameters are characterized and applied in the final design of the assay system. In the cCRP system studied, 90 % of the binding between immobilized solid-phase silica antibody and cCRP is complete after only 15 s, and 30 s for the binding between the antibody on the SPION and the bound cCRP on the silica particle. Additionally, the binding rate constants are determined to be 149 and 30 M(-1)s(-1), respectively. The analytical sensitivity, clinical sensitivity, and imprecision verifies the clinical usefulness of the system. Also, quantification of cCRP, using the system described, in dog clinical samples from mixed breeds shows a high correlation to a commercially available comparative cCRP ELISA system (y = 0.98 x +3.2, R (2) = 0.98, n = 47). The immunoassay system described can thus provide the veterinarian a valuable tool for rapid diagnosis and monitoring of inflammatory diseases in dogs in a setting near the patients.
引用
收藏
页码:6001 / 6007
页数:7
相关论文
共 34 条
[1]   ENZYME-BASED DETECTION OF GLYCOPROTEINS ON BLOT TRANSFERS USING AVIDIN-BIOTIN TECHNOLOGY [J].
BAYER, EA ;
BENHUR, H ;
WILCHEK, M .
ANALYTICAL BIOCHEMISTRY, 1987, 161 (01) :123-131
[2]  
BAYER EA, 1990, METHOD ENZYMOL, V184, P427
[3]   HIGHER ANTI-TUMOR EFFICACY OF DAUNOMYCIN WHEN LINKED TO DEXTRAN - INVIVO AND INVITRO STUDIES [J].
BERNSTEIN, A ;
HURWITZ, E ;
MARON, R ;
ARNON, R ;
SELA, M ;
WILCHEK, M .
JOURNAL OF THE NATIONAL CANCER INSTITUTE, 1978, 60 (02) :379-384
[4]   DEXTRAN, A HAPTEN CARRIER IN IMMUNOASSAYS FOR S-TRIAZINES - A COMPARISON WITH ELISAS BASED ON HAPTEN-PROTEIN CONJUGATES [J].
BOCHER, M ;
GIERSCH, T ;
SCHMID, RD .
JOURNAL OF IMMUNOLOGICAL METHODS, 1992, 151 (1-2) :1-8
[5]   PRODUCTION OF SPECIFIC MONOCLONAL-ANTIBODIES AGAINST THE ACTIVE-SITES OF HUMAN PANCREATIC SECRETORY TRYPSIN-INHIBITOR VARIANTS BY INVITRO IMMUNIZATION WITH SYNTHETIC PEPTIDES [J].
BOLDICKE, T ;
KINDT, S ;
MAYWALD, F ;
FITZLAFF, G ;
BOCHER, M ;
FRANK, R ;
COLLINS, J .
EUROPEAN JOURNAL OF BIOCHEMISTRY, 1988, 175 (02) :259-264
[6]   Use of high-capacity surface with oriented recombinant antibody fragments in a 5-min immunoassay for thyroid-stimulating hormone [J].
Brockmann, Eeva-Christine ;
Vehniainen, Markus ;
Pettersson, Kim .
ANALYTICAL BIOCHEMISTRY, 2010, 396 (02) :242-249
[7]  
Carlsson J, 1996, BIOTECHNOL BIOENG, V51, P221, DOI 10.1002/(SICI)1097-0290(19960720)51:2<221::AID-BIT12>3.0.CO
[8]  
2-P
[9]  
CASPI D, 1987, AM J VET RES, V48, P919
[10]  
CASPI D, 1984, IMMUNOLOGY, V53, P307