Longitudinal Hemodynamics of Aortic Bioprosthetic Valve in Hemodialysis Patients

被引:2
作者
Kinoshita, Takeshi [1 ]
Yoshida, Kumi [2 ]
Suzuki, Tomoaki [1 ]
Asai, Tohru [1 ,3 ]
机构
[1] Shiga Univ Med Sci, Div Cardiovasc Surg, Otsu, Japan
[2] Shiga Univ Med Sci, Dept Clin Engn, Otsu, Japan
[3] Juntendo Univ, Dept Cardiovasc Surg, Tokyo, Japan
关键词
Aortic valve replacement; Bioprosthesis; Hemodialysis; Structural valve deterioration; LEFT-VENTRICULAR HYPERTROPHY; VASCULAR CALCIFICATION; TERM OUTCOMES; HANCOCK II; FOLLOW-UP; REPLACEMENT; OSTEOPROTEGERIN; STENOSIS; RISK; DEGENERATION;
D O I
10.1053/j.semtcvs.2021.08.028
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We examined the hemodynamic profile of bioprosthetic aortic valves in patients on hemodialysis (HD), longitudinally, and assess the incidence of adverse changes detected by echocardiography. Of 1,146 consecutive patients with severe aortic stenosis who underwent bioprosthetic aortic valve replacement (AVR), 148 patients had end-stage renal disease requiring HD. Each patient on HD was matched one-to-one with a non-HD patient on the basis of propensity scores. The mean follow-up period was 3.3 years for the HD group and 5.9 years for the non-HD group. Follow-up information was available for 95.2%. Postoperative trends of valve hemodynamics derived from linear mixed-effect models showed significant group vs time interactions between the two groups. Stable hemodynamics was consistently observed in the non-HD group, whereas the HD group showed a decrease of -0.06 cm2/y (95% confidence interval (CI), -0.10 to -0.02) in effective orifice area, an increase of 0.8 mm Hg/year (95% CI, 0.4–1.1) in mean pressure gradient, and an increase of 0.08 m/s/year (95%CI, 0.02–0.13) in peak velocity. Cumulative incidence function of SVD more than stage 2 was significantly higher in the HD group (13.1% vs 3.1% at 5 years, Gray test p = 0.01). In a multivariable Fine-Gray analysis, diabetes was independently associated with SVD more than stage 2 in the HD group (subhazard ratio, 1.91; 95% CI, 1.25–2.89; p = 0.02). Survival free-from stenotic-type SVD was significantly lower in HD patients undergoing bioprosthetic AVR. Diabetes was independently associated with postoperative stenotic-type SVD in HD patients. © 2021 Elsevier Inc.
引用
收藏
页码:1182 / 1192
页数:11
相关论文
共 35 条
[11]   Left Ventricular Mass in Chronic Kidney Disease and ESRD [J].
Glassock, Richard J. ;
Pecoits-Filho, Roberto ;
Barberato, Silvio H. .
CLINICAL JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 2009, 4 :S79-S91
[12]   A CLASS OF K-SAMPLE TESTS FOR COMPARING THE CUMULATIVE INCIDENCE OF A COMPETING RISK [J].
GRAY, RJ .
ANNALS OF STATISTICS, 1988, 16 (03) :1141-1154
[13]  
HARNETT JD, 1994, J AM SOC NEPHROL, V4, P1486
[14]   Outcomes of valve replacement with mechanical prosthesis versus bioprosthesis in dialysis patients: A 16-year multicenter experience [J].
Ikeno, Yuki ;
Mukohara, Nobuhiko ;
Fukumura, Yoshiaki ;
Tobe, Satoshi ;
Gan, Kunio ;
Obo, Hidefumi ;
Yoshida, Kazunori ;
Okita, Yutaka .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2019, 158 (01) :48-+
[15]   Early Postoperative Bioprosthetic Valve Calcification [J].
Iyer, Anand ;
Malik, Paras ;
Prabha, Ramesh ;
Kugathasan, Gana ;
Kuteyi, Opeyemi ;
Marney, Lucy ;
Larbalestier, Robert .
HEART LUNG AND CIRCULATION, 2013, 22 (10) :873-874
[16]   Receptor activator of nuclear factor κB ligand and osteoprotegerin regulate aortic valve calcification [J].
Kaden, JJ ;
Bickelhaupt, S ;
Grobholz, R ;
Haase, KK ;
Sartkoç, A ;
Kiliç, R ;
Brueckmann, M ;
Lang, S ;
Zahn, I ;
Vahl, C ;
Hagl, S ;
Dempfle, CE ;
Borggrefe, M .
JOURNAL OF MOLECULAR AND CELLULAR CARDIOLOGY, 2004, 36 (01) :57-66
[17]   DIASTOLIC DYSFUNCTION AS A CAUSE OF HEART-FAILURE [J].
LITWIN, SE ;
GROSSMAN, W .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1993, 22 (04) :A49-A55
[18]   Type 2 Diabetes Mellitus Is Associated With Faster Degeneration of Bioprosthetic Valve Results From a Propensity Score-Matched Italian Multicenter Study [J].
Lorusso, Roberto ;
Gelsomino, Sandro ;
Luca, Fabiana ;
De Cicco, Giuseppe ;
Bille, Giuseppe ;
Carella, Rocco ;
Villa, Emanuel ;
Troise, Gianni ;
Vigano, Mario ;
Banfi, Carlo ;
Gazzaruso, Carmine ;
Gagliardotto, Pier ;
Menicanti, Lorenzo ;
Formica, Francesco ;
Paolini, Giovanni ;
Benussi, Stefano ;
Alfieri, Ottavio ;
Pastore, Matteo ;
Ferrarese, Sandro ;
Mariscalco, Giovanni ;
Di Credico, Germano ;
Leva, Cristian ;
Russo, Claudio ;
Cannata, Aldo ;
Trevisan, Roberto ;
Livi, Ugolino ;
Scrofani, Roberto ;
Antona, Carlo ;
Sala, Andrea ;
Gensini, Gian Franco ;
Maessen, Jos ;
Giustina, Andrea .
CIRCULATION, 2012, 125 (04) :604-614
[19]   A 20-year multicenter analysis of dialysis-dependent patients who had aortic or mitral valve replacement: Implications for valve selection [J].
Manghelli, Joshua L. ;
Carter, Daniel I. ;
Khiabani, Ali J. ;
Gauthier, Jason M. ;
Moon, Marc R. ;
Munfakh, Nabil A. ;
Damiano, Ralph J. ;
Corvera, Joel S. ;
Melby, Spencer J. .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2019, 158 (03) :805-+
[20]   Late Outcomes for Aortic Valve Replacement With the Carpentier-Edwards Pericardial Bioprosthesis: Up to 17-Year Follow-Up in 1,000 Patients [J].
McClure, R. Scott ;
Narayanasamy, Narendren ;
Wiegerinck, Esther ;
Lipsitz, Stuart ;
Maloney, Ann ;
Byrne, John G. ;
Aranki, Sary F. ;
Couper, Gregory S. ;
Cohn, Lawrence H. .
ANNALS OF THORACIC SURGERY, 2010, 89 (05) :1410-1416