Longitudinal Hemodynamics of Aortic Bioprosthetic Valve in Hemodialysis Patients

被引:2
作者
Kinoshita, Takeshi [1 ]
Yoshida, Kumi [2 ]
Suzuki, Tomoaki [1 ]
Asai, Tohru [1 ,3 ]
机构
[1] Shiga Univ Med Sci, Div Cardiovasc Surg, Otsu, Japan
[2] Shiga Univ Med Sci, Dept Clin Engn, Otsu, Japan
[3] Juntendo Univ, Dept Cardiovasc Surg, Tokyo, Japan
关键词
Aortic valve replacement; Bioprosthesis; Hemodialysis; Structural valve deterioration; LEFT-VENTRICULAR HYPERTROPHY; VASCULAR CALCIFICATION; TERM OUTCOMES; HANCOCK II; FOLLOW-UP; REPLACEMENT; OSTEOPROTEGERIN; STENOSIS; RISK; DEGENERATION;
D O I
10.1053/j.semtcvs.2021.08.028
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We examined the hemodynamic profile of bioprosthetic aortic valves in patients on hemodialysis (HD), longitudinally, and assess the incidence of adverse changes detected by echocardiography. Of 1,146 consecutive patients with severe aortic stenosis who underwent bioprosthetic aortic valve replacement (AVR), 148 patients had end-stage renal disease requiring HD. Each patient on HD was matched one-to-one with a non-HD patient on the basis of propensity scores. The mean follow-up period was 3.3 years for the HD group and 5.9 years for the non-HD group. Follow-up information was available for 95.2%. Postoperative trends of valve hemodynamics derived from linear mixed-effect models showed significant group vs time interactions between the two groups. Stable hemodynamics was consistently observed in the non-HD group, whereas the HD group showed a decrease of -0.06 cm2/y (95% confidence interval (CI), -0.10 to -0.02) in effective orifice area, an increase of 0.8 mm Hg/year (95% CI, 0.4–1.1) in mean pressure gradient, and an increase of 0.08 m/s/year (95%CI, 0.02–0.13) in peak velocity. Cumulative incidence function of SVD more than stage 2 was significantly higher in the HD group (13.1% vs 3.1% at 5 years, Gray test p = 0.01). In a multivariable Fine-Gray analysis, diabetes was independently associated with SVD more than stage 2 in the HD group (subhazard ratio, 1.91; 95% CI, 1.25–2.89; p = 0.02). Survival free-from stenotic-type SVD was significantly lower in HD patients undergoing bioprosthetic AVR. Diabetes was independently associated with postoperative stenotic-type SVD in HD patients. © 2021 Elsevier Inc.
引用
收藏
页码:1182 / 1192
页数:11
相关论文
共 35 条
[1]   Aortic Stenosis in Dialysis Patients [J].
Ahmad, Yousif ;
Bellamy, Michael F. ;
Baker, Christopher S. R. .
SEMINARS IN DIALYSIS, 2017, 30 (03) :224-231
[2]   Balance diagnostics for comparing the distribution of baseline covariates between treatment groups in propensity-score matched samples [J].
Austin, Peter C. .
STATISTICS IN MEDICINE, 2009, 28 (25) :3083-3107
[3]   Increased levels of osteoprotegerin in hemodialysis patients [J].
Avbersek-Luznik, I ;
Malesic, I ;
Rus, I ;
Marc, J .
CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2002, 40 (10) :1019-1023
[4]   Long-Term Clinical and Hemodynamic Performance of the Hancock II Versus the Perimount Aortic Bioprostheses [J].
Chan, Vincent ;
Kulik, Alexander ;
Tran, Anthony ;
Hendry, Paul ;
Masters, Roy ;
Mesana, Thierry G. ;
Ruel, Marc .
CIRCULATION, 2010, 122 (11) :S10-S16
[5]   Is left ventricular hypertrophy a modifiable risk factor in end-stage renal disease [J].
Charytan, David .
CURRENT OPINION IN NEPHROLOGY AND HYPERTENSION, 2014, 23 (06) :578-585
[6]   Regulation of vascular calcification by osteoclast regulatory factors RANKL and osteoprotegerin [J].
Collin-Osdoby, P .
CIRCULATION RESEARCH, 2004, 95 (11) :1046-1057
[7]   Hancock II Bioprosthesis for Aortic Valve Replacement: The Gold Standard of Bioprosthetic Valves Durability? [J].
David, Tirone E. ;
Armstrong, Susan ;
Maganti, Manjula .
ANNALS OF THORACIC SURGERY, 2010, 90 (03) :775-781
[8]   Echocardiographic Imaging in Clinical Trials: American Society of Echocardiography Standards for Echocardiography Core Laboratories Endorsed by the American College of Cardiology Foundation [J].
Douglas, Pamela S. ;
DeCara, Jeanne M. ;
Devereux, Richard B. ;
Duckworth, Shelly ;
Gardin, Julius M. ;
Jaber, Wael A. ;
Morehead, Annitta J. ;
Oh, Jae K. ;
Picard, Michael H. ;
Solomon, Scott D. ;
Wei, Kevin ;
Weissman, Neil J. .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2009, 22 (07) :755-765
[9]   Standardized Definition of Structural Valve Degeneration for Surgical and Transcatheter Bioprosthetic Aortic Valves [J].
Dvir, Danny ;
Bourguignon, Thierry ;
Otto, Catherine M. ;
Hahn, Rebecca T. ;
Rosenhek, Raphael ;
Webb, John G. ;
Treede, Hendrik ;
Sarano, Maurice E. ;
Feldman, Ted ;
Wijeysundera, Harindra C. ;
Topilsky, Yan ;
Aupart, Michel ;
Reardon, Michael J. ;
Mackensen, G. Burkhard ;
Szeto, Wilson Y. ;
Kornowski, Ran ;
Gammie, James S. ;
Yoganathan, Ajit P. ;
Arbel, Yaron ;
Borger, Michael A. ;
Simonato, Matheus ;
Reisman, Mark ;
Makkar, Raj R. ;
Abizaid, Alexandre ;
McCabe, James M. ;
Dahle, Gry ;
Aldea, Gabriel S. ;
Leipsic, Jonathon ;
Pibarot, Philippe ;
Moat, Neil E. ;
Mack, Michael J. ;
Kappetein, A. Pieter ;
Leon, Martin B. .
CIRCULATION, 2018, 137 (04) :388-399
[10]   A proportional hazards model for the subdistribution of a competing risk [J].
Fine, JP ;
Gray, RJ .
JOURNAL OF THE AMERICAN STATISTICAL ASSOCIATION, 1999, 94 (446) :496-509