Absolute self-calibrated room-temperature terahertz powermeter

被引:6
|
作者
Pradere, Christophe [1 ]
Caumes, Jean-Pascal [1 ]
Toutain, Jean [1 ]
Abraham, Emmanuel [2 ]
Chassagne, Bruno [3 ]
Batsale, Jean-Christophe [1 ]
机构
[1] CNRS, TREFLE Dept I2M, UMR Esplanade Arts & Metiers 5295, F-33405 Talence, France
[2] Univ Bordeaux, CNRS, LOMA, UMR 5798, F-33405 Talence, France
[3] ALPhANOV, Technol Laser & Opt Ctr, F-33405 Talence, France
关键词
Broadband response - High sensitivity - Optical and thermal properties - Performance characteristics - Powermeter - Self calibration - Temperature measuring - Thermal converters;
D O I
10.1364/AO.52.002320
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Coupling optical and thermal properties of a terahertz (THz) thermal converter based on the Seebeck effect provides an unsupplied room-temperature measuring device dedicated to THz power metrology. Performance characteristics such as broadband response (0-30 THz), high sensitivity (<25 mu W.Hz(-0.5)), and the possibility to develop an internal absolute self-calibration estimated at 9.93 W.V-1 are reported. Advantages and drawbacks of this THz powermeter are discussed. (C) 2013 Optical Society of America
引用
收藏
页码:2320 / 2324
页数:5
相关论文
共 50 条
  • [21] Room-Temperature Terahertz Oscillation of Resonant Tunneling Diodes
    Asada, Masahiro
    Suzuki, Safumi
    TERAHERTZ EMITTERS, RECEIVERS, AND APPLICATIONS IV, 2013, 8846
  • [22] Room-temperature operation of an electrically driven terahertz modulator
    Kleine-Ostmann, T
    Dawson, P
    Pierz, K
    Hein, G
    Koch, M
    APPLIED PHYSICS LETTERS, 2004, 84 (18) : 3555 - 3557
  • [23] Room-temperature operation of a unipolar nanodiode at terahertz frequencies
    Balocco, Claudio
    Kasjoo, Shahrir R.
    Lu, Xiaofeng F.
    Zhang, Linqing Q.
    Alimi, Yasaman
    Winnerl, Stephan
    Song, Aimin M.
    APPLIED PHYSICS LETTERS, 2011, 98 (22)
  • [24] A Self-Calibrated Transfer Standard for Microwave Calorimetry
    Gu, Dazhen
    Lu, Xifeng
    Jamroz, Ben
    Williams, Dylan
    Riddle, Bill
    Cui, Xiaohai
    2018 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS (CPEM 2018), 2018,
  • [25] A self-calibrated bandgap voltage reference with 0.5 ppm/°C temperature coefficient
    Jin, Le
    Xing, Hanqing
    Chen, Degang
    Geiger, Randall
    2006 IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS, VOLS 1-11, PROCEEDINGS, 2006, : 2853 - +
  • [26] Self-Calibrated Absolute Thickness Measurement of Opaque Specimen Based on Differential White Light Interferometry
    Lu, Xu
    Yuan, Yonggui
    Ma, Chi
    Zhu, Haibo
    Zhu, Yunlong
    Yu, Zhangjun
    Zhang, Xiaojun
    Jiang, Fuqiang
    Zhang, Jianzhong
    Li, Hanyang
    Yang, Jun
    Yuan, Libo
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2020, 69 (05) : 2507 - 2514
  • [27] Self-calibrated convolution towards glioma segmentation
    Salvagnini, Felipe C. R.
    Barbosa, Gerson O.
    Falcao, Alexandre X.
    Santos, Cid A. N.
    2023 19TH INTERNATIONAL SYMPOSIUM ON MEDICAL INFORMATION PROCESSING AND ANALYSIS, SIPAIM, 2023,
  • [28] Self-calibrated Mueller matrix spectroscopic ellipsometry
    Bang, KY
    An, JS
    An, I
    Collins, RW
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2004, 45 (01) : 185 - 188
  • [29] Self-Calibrated Warping for Mass Spectra Alignment
    He, Q. Peter
    Wang, Jin
    Mobley, James A.
    Richman, Joshua
    Grizzle, William E.
    CANCER INFORMATICS, 2011, 10 : 65 - 82
  • [30] Self-calibrated robotic manipulator force observer
    Garcia, J. Gamez
    Robertsson, A.
    Ortega, J. Gomez
    Johansson, R.
    ROBOTICS AND COMPUTER-INTEGRATED MANUFACTURING, 2009, 25 (02) : 366 - 378