A Comparative Study of Dielectric Dissipation Factor Measurement under Very Low and Power Frequencies

被引:0
|
作者
Morsalin, S. [1 ]
Phung, B. T. [1 ]
机构
[1] Univ New South Wales, Sch Elect Engn & Telecommun, Sydney, NSW, Australia
来源
2017 3RD INTERNATIONAL CONFERENCE ON CONDITION ASSESSMENT TECHNIQUES IN ELECTRICAL SYSTEMS (CATCON) | 2017年
关键词
Correlation; diagnostic assessment; dissipation factor; tan delta; very-low-frequency (VLF); DELTA DIAGNOSTIC MEASUREMENTS; CABLES; VLF;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Very low frequency (VLF) high voltage testing had been used as a simple withstand test (go/no-go). Recently, VLF diagnostic testing has emerged as a promising tool for insulation assessment of power cables. The term VLF implies testing insulation with an excitation voltage at frequency of 0.1 Hz or lower. In this paper, a comparative analysis of the dielectric dissipation factor (DDF) or tan delta measurement is presented for 11-kV cross-linked polyethylene (XLPE) cable at power frequency (50 Hz) and at VLF. Here, the DDF response is measured from frequency 50 Hz to 0.1 Hz for four short cable sections where each sample has a capacitance lower than 300 pF. The experimental results show that the DDF value at 0.1 Hz is much higher than that at 50 Hz. Furthermore, differential tangent delta (DTD) and correlation of DDF values are calculated to incorporate with experimental results.
引用
收藏
页码:10 / 14
页数:5
相关论文
共 15 条
  • [1] A Comparative Study of Partial Discharges Under Power and Very Low Frequency Voltage Excitation
    Dao, Thinh
    Phung, B. T.
    Blackburn, T.
    Nguyen, H. V. P.
    2014 IEEE CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA (CEIDP), 2014, : 164 - 167
  • [2] Comparative Phase-Resolved Analysis of AC Corona Discharges at Very Low (0.1 Hz) and Power Frequencies
    Morsalin, S.
    Phung, B. T.
    2017 INTERNATIONAL CONFERENCE ON HIGH VOLTAGE ENGINEERING AND POWER SYSTEMS (ICHVEPS), 2017, : 165 - 169
  • [3] Insulation Assessment Based on Dielectric Dissipation Factor Measurement under Non-sinusoidal Excitation
    Muntakim, Pratic A.
    Zhang, Shubin
    Zhang, Junyang
    Phung, B. T.
    PROCEEDINGS OF 2021 5TH INTERNATIONAL CONFERENCE ON CONDITION ASSESSMENT TECHNIQUES IN ELECTRICAL SYSTEMS (IEEE CATCON 2021), 2021, : 242 - 246
  • [4] Parasitic Effect - Independent Approach for Dissipation Factor Measurement in Power Transformers
    Peretto, Lorenzo
    Tinarelli, Roberto
    Puricelli, Mauro
    2013 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE (I2MTC), 2013, : 1426 - 1430
  • [6] Dissipation Factor of Acrylic Dielectric Elastomer-An Experimental Study
    Sahu, Raj Kumar
    Pramanik, Bipul
    Patra, Karali
    Bhaumik, Shovan
    Pandey, Arvind Kumar
    Setua, Dipak Kumar
    JOURNAL OF NANOSCIENCE AND NANOTECHNOLOGY, 2014, 14 (10) : 7439 - 7444
  • [7] Investigation of Very Low Frequency Dissipation Factor of the Contaminated Underground Cable Joints
    Suksawat, Dusit
    Hengcharoensuk, Tassana
    Nupinit, Thanapon
    Chusang, Kittidech
    Ravangvong, Tanachot
    Pattanadech, Norasage
    2020 8TH INTERNATIONAL CONFERENCE ON CONDITION MONITORING AND DIAGNOSIS (CMD 2020), 2020, : 342 - 345
  • [8] Low-Cost System of Direct Measurement of Dissipation Factor for High-Voltage Electrical Machine
    Bandyopadhyay, Mandakinee
    Chattopadhyay, Subrata
    Roy, Ganesh
    Mandal, Nirupama
    Bera, Satish Chandra
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2020, 69 (04) : 1547 - 1555
  • [9] Structural Changes and Very-Low-Frequency Nonlinear Dielectric Response of XLPE Cable Insulation under Thermal Aging
    Wang, Can
    Zhao, Xuetong
    Qiao, Jingqi
    Xiao, Yongjian
    Zhang, Jie
    Li, Yuchen
    Cao, Hanzhong
    Yang, Lijun
    Liao, Ruijin
    MATERIALS, 2023, 16 (12)