Development of Life-Size Patient-Specific 3D-Printed Dural Venous Models for Preoperative Planning

被引:14
作者
Govsa, Figen [1 ]
Karakas, Asli Beril [1 ]
Ozer, Mehmet Asim [1 ]
Eraslan, Cenk [2 ]
机构
[1] Ege Univ, Fac Med, Dept Anat, Digital Imaging & Modelling Lab, Izmir, Turkey
[2] Ege Univ, Fac Med, Dept Radiol, Izmir, Turkey
关键词
3D printing model; Brain imaging; Dural venous sinuses; Minimally invasive neurosurgery; Preoperative planning; Surgical trainers; Vascular model; STEREOTACTIC RADIOSURGERY; ARTERIOVENOUS-FISTULAS; NORMAL ANATOMY; MR VENOGRAPHY; 3D; SIMULATION; SINUSES;
D O I
10.1016/j.wneu.2017.10.119
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND: Despite significant improvement in clinical care, operative strategies, and technology, neurosurgery is still risky, and optimal preoperative planning and anatomical assessment are necessary to minimize the risks of serious complications. Our purpose was to document the dural venous sinuses (DVS) and their variations identified during routine 3-dimensional (3D) venography created through 3D models for the teaching of complex cerebral anatomy. METHODS: 3D models of the DVS networks were printed. Compared with the controls, cases with cortical venous thrombosis have altered venous anatomy, which has not been previously compared. RESULTS: Geometrical changes between the neighboring DVS could be easily manipulated and explored from different angles. Modeling helped to conduct the examination in detail with reference to geometrical features of DVS, degree of asymmetry, its extension, location, and presence of hypoplasia/atresia channels. Challenging DVS anatomy was exposed with models of adverse anatomical variations of the DVS network, including highly angulated, asymmetrical view, narrowed lumens, and hypoplasia and atresia structures. It assisted us in comprehending spatial anatomy configuration of life-like models. CONCLUSIONS: Patient-specific models of DVS geometry could provide an improved understanding of the complex brain anatomy and better navigation in difficult areas and allow surgeons to anticipate anatomical issues that might arise during the operation. Such models offer opportunities to accelerate the development of expertise with respect to new and novel procedures as well as new surgical approaches and innovations, thus allowing novice neurosurgeons to gain valuable experience in surgical techniques without exposing patients to risk of harm.
引用
收藏
页码:E141 / E149
页数:9
相关论文
共 40 条
[31]   Surgical advantages of using 3D patient-specific models in high-energy tibial plateau fractures [J].
Anil Murat Ozturk ;
Onur Suer ;
Okan Derin ;
Mehmet Asim Ozer ;
Figen Govsa ;
Kemal Aktuglu .
European Journal of Trauma and Emergency Surgery, 2020, 46 :1183-1194
[32]   Scan, plan, print, practice, perform: Development and use of a patient-specific 3-dimensional printed model in adult cardiac surgery [J].
Hermsen, Joshua L. ;
Burke, Thomas M. ;
Seslar, Stephen P. ;
Owens, David S. ;
Ripley, Beth A. ;
Mokadam, Nahush A. ;
Verrier, Edward D. .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2017, 153 (01) :132-140
[33]   The utility of 3D printing for surgical planning and patient-specific implant design for complex spinal pathologies: case report [J].
Mobbs, Ralph J. ;
Coughlan, Marc ;
Thompson, Robert ;
Sutterlin, Chester E., III ;
Phan, Kevin .
JOURNAL OF NEUROSURGERY-SPINE, 2017, 26 (04) :513-518
[34]   Embolization using patient-specific vascular models created by a 3D printer for difficult cases: a report of two cases [J].
Komada, Tomohiro ;
Kamomae, Takeshi ;
Matsushima, Masaya ;
Hyodo, Ryota ;
Naganawa, Shinji .
NAGOYA JOURNAL OF MEDICAL SCIENCE, 2022, 84 (02) :477-483
[35]   Clinical Implementation of In-House Developed MR-Based Patient-Specific 3D Models of Liver Anatomy [J].
Ivashchenko, Oleksandra, V ;
Smit, Jasper N. ;
Nijkamp, Jasper ;
ter Beek, Leon C. ;
Rijkhorst, Erik-Jan ;
Kok, Niels F. M. ;
Ruers, Theo J. M. ;
Kuhlmann, Koert F. D. .
EUROPEAN SURGICAL RESEARCH, 2021, 61 (4-5) :143-152
[36]   Narrative review of patient-specific 3D visualization and reality technologies in skull base neurosurgery: enhancements in surgical training, planning, and navigation [J].
Isikay, Ilkay ;
Cekic, Efecan ;
Baylarov, Baylar ;
Tunc, Osman ;
Hanalioglu, Sahin .
FRONTIERS IN SURGERY, 2024, 11
[37]   Potential of computational models in personalized treatment of obstructive sleep apnea: a patient-specific partial 3D finite element study [J].
Ayyalasomayajula, Venkat ;
Moxness, Mads ;
Skallerud, Bjorn .
BIOMECHANICS AND MODELING IN MECHANOBIOLOGY, 2024, 23 (02) :507-524
[38]   Patient-specific CFD models for intraventricular flow analysis from 3D ultrasound imaging: Comparison of three clinical cases [J].
Bavo, A. M. ;
Pouch, A. M. ;
Degroote, J. ;
Vierendeels, J. ;
Gorman, J. H. ;
Gorman, R. C. ;
Segers, P. .
JOURNAL OF BIOMECHANICS, 2017, 50 :144-150
[39]   Comparison of 3D computer-assisted planning with and without patient-specific instrumentation for severe bone defects in reverse total shoulder arthroplasty [J].
Yelton, Mitchell J. ;
Da Silva, Adrik Z. ;
Moverman, Michael A. ;
Joyce, Christopher D. ;
Chalmers, Peter N. ;
Tashjian, Robert Z. .
JOURNAL OF SHOULDER AND ELBOW SURGERY, 2024, 33 (12) :2629-2636
[40]   Quantify patient-specific coronary material property and its impact on stress/strain calculations using in vivo IVUS data and 3D FSI models: a pilot study [J].
Guo, Xiaoya ;
Zhu, Jian ;
Maehara, Akiko ;
Monoly, David ;
Samady, Habib ;
Wang, Liang ;
Billiar, Kristen L. ;
Zheng, Jie ;
Yang, Chun ;
Mintz, Gary S. ;
Giddens, Don P. ;
Tang, Dalin .
BIOMECHANICS AND MODELING IN MECHANOBIOLOGY, 2017, 16 (01) :333-344