Airflow and Combustion Characteristics and NOx Formation of the Low-Volatile Coal-Fired Utility Boiler at Different Loads

被引:0
作者
Li, Song [1 ]
Chen, Zhichao [1 ]
Jiang, Bingkun [1 ]
Liu, Guangkui [1 ,2 ]
Li, Zhengqi [1 ]
Zhang, Xiqian [1 ,3 ]
Zhu, Qunyi [1 ]
机构
[1] Harbin Inst Technol, Sch Energy Sci & Engn, Harbin 150001, Peoples R China
[2] China Special Equipment Inspect & Res Inst, Beijing 100029, Peoples R China
[3] China Huadian Engn Co Ltd, Beijing 100160, Peoples R China
来源
CLEAN COAL TECHNOLOGY AND SUSTAINABLE DEVELOPMENT | 2016年
关键词
Wall-fired boiler; Centrally fuel-rich swirl burner; No-x; Industrial experiment; EMISSIONS;
D O I
10.1007/978-981-10-2023-0_26
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In order to solve the problems of lower heating rate of the primary air/fuel mixture and higher NOx emission of the boiler, both the small-scale cold air experiment of a single burner and industrial-scale experiments of the centrally fuel-rich (CFR) swirl burner on a retrofitted 300 MW wall-fired boiler fed with low-volatile coal under deep air staging were performed. The aerodynamic characteristics, flue gas temperature, and temperature distribution of the furnace and carbon content in the fly ash were measured at loads of 300, 230, and 150 MW. Results illustrate that a central recirculation zone appeared close to the outlet of the CFR burner under deep air staging. Compared with the enhanced ignition-dual register (EI-DR) burner, the gas temperature and the heating rate of the CFR burner is much higher, so it can guarantee the timely ignition and stable combustion of the pulverized coal. As for the CFR burner, with a decreasing load, the heating rate of the gas temperature decreases and the ignition position of the primary coal/air mixture become backward. The overall temperature of the furnace also decreases with decreasing load, as does the difference between the temperatures in the burning region and the lower position of the burnout region. After the retrofitting of the combustion system, the exhaust gas temperature decreases from 149 to 146 degrees C, the NOx emissions at the air preheater exits decrease from 1354 to 778 mg/m(3) (6 % O-2), and the boiler thermal efficiency increases from 89.75-90.57 % at the rated load.
引用
收藏
页码:197 / 205
页数:9
相关论文
共 12 条
  • [1] Bi Y, 2005, THERMAL POWER GENERA, V34, P7
  • [2] [曹湘洪 Cao Xianghong], 2011, [化工进展, Chemical Industry and Engineering Progress], V30, P80
  • [3] DE DS, 1981, J I ENERGY, V54, P113
  • [4] Effect of Air-Staging on Anthracite Combustion and NOx Formation
    Fan, Weidong
    Lin, Zhengchun
    Li, Youyi
    Kuang, Jinguo
    Zhang, Mingchuan
    [J]. ENERGY & FUELS, 2009, 23 (1-2) : 111 - 120
  • [5] Influence of Different Outer Secondary Air Vane Angles on Flow and Combustion Characteristics and NOx Emissions of a New Swirl Coal Burner
    Jing, Jianping
    Li, Zhengqi
    Liu, Guangkui
    Chen, Zhichao
    Ren, Feng
    [J]. ENERGY & FUELS, 2010, 24 (01) : 346 - 354
  • [6] Improving Combustion Characteristics and NOx Emissions of a Down-Fired 350 MWe Utility Boiler with Multiple Injection and Multiple Staging
    Kuang, Min
    Li, Zhengqi
    Xu, Shantian
    Zhu, Qunyi
    [J]. ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2011, 45 (08) : 3803 - 3811
  • [7] NOx emission and thermal efficiency of a 300 MWe utility boiler retrofitted by air staging
    Li, Sen
    Xu, Tongmo
    Hui, Shien
    Wei, Xiaolin
    [J]. APPLIED ENERGY, 2009, 86 (09) : 1797 - 1803
  • [8] Li ZQ, 2002, FUEL, V81, P829
  • [9] Influence of division cone angles between the fuel-rich and the fuel-lean ducts on gas-particle flow and combustion near swirl burners
    Qi, LZ
    ZhiXin, W
    Rui, S
    ShaoZeng, S
    LiZhe, C
    ShaoHua, W
    YuKun, Q
    [J]. ENERGY, 2002, 27 (12) : 1119 - 1130
  • [10] Detailed measurements in a pulverized-coal-fired large-scale laboratory furnace with air staging
    Ribeirete, A.
    Costa, M.
    [J]. FUEL, 2009, 88 (01) : 40 - 45