Three-dimensional analysis of acetabular orientation using a semi-automated algorithm

被引:9
|
作者
Lee, Changhwan [1 ]
Jang, Jongseong [2 ]
Kim, Hyung Wook [3 ]
Kim, Young Soo [3 ]
Kim, Yeesuk [4 ]
机构
[1] Hanyang Univ, Dept Biomed Engn, Seoul, South Korea
[2] Kyushu Univ, Dept Adv Med Initiat, Ctr Integrat Adv Med Life Sci Innovat Technol CAM, Fukuoka, Japan
[3] Hanyang Univ, Inst Innovat Surg Technol, Seoul, South Korea
[4] Hanyang Univ, Dept Orthoped Surg, 222 Wangsimni Ro, Seoul 133791, South Korea
基金
新加坡国家研究基金会;
关键词
Acetabulum; acetabular orientation; total hip arthroplasty; computed tomography; Asian; ANTERIOR PELVIC PLANE; CUP; TILT;
D O I
10.1080/24699322.2018.1545872
中图分类号
R61 [外科手术学];
学科分类号
摘要
Understanding the morphology of the acetabulum is necessary for preoperative evaluation in hip surgery. The purpose of this study was to (1) establish a novel method for measuring three-dimensional (3D) acetabular orientation, (2) quantify the reliability of this method, and (3) describe relevant characteristics of three-dimensional (3D) acetabular orientation among normal Asian subjects. Computed tomography (CT) scans of the pelvis that had been performed for suspected non-musculoskeletal conditions were obtained from 200 subjects (60 males, 140 females). A novel method was developed to measure 3D acetabular orientation with a semiautomatically determined pelvic coordinate system based on the anterior pelvic plane (APP). To quantify the robustness of our method, we analyzed the results obtained from 20 patients at different times and with different raters and pelvic poses in the same CT volume. To determine morphological differences of the acetabulum by age and sex, we analyzed the parameters of 200 CT volumes. Each intraclass correlation coefficient (ICC) values for intra- and inter-observer reliability were over 0.975 and 0.945, demonstrating high reliability. Furthermore, agreement between the angles determined from the original volume and the rotated volume was nearly perfect (ICCs>0.956). Multiple linear regression analysis with age and sex as covariates indicated that acetabular inclination was not significantly associated with age (p = 0.687) or sex (p = 0.09). There was also no evidence that acetabular anteversion was associated with age (p = 0.383) or sex (p = 0.53). Our method showed excellent reliability for determining acetabular orientation, as it is robust, fast, and easily applicable to larger populations. In addition, the results of the analysis of acetabular orientation by age and sex can be used as a reference in various diagnostic procedures in orthopedics.
引用
收藏
页码:18 / 25
页数:8
相关论文
共 50 条
  • [1] Semi-automated analysis of three-dimensional track images
    Meesen, G
    Poffijn, A
    RADIATION MEASUREMENTS, 2001, 34 (1-6) : 161 - 165
  • [2] Semi-Automated Three-Dimensional Condylar Reconstruction
    Mendez-Manjon, Irene
    Haas Jr, Orion Luiz
    Guijarro-Martinez, Raquel
    de Oliveira, Rogerio Belle
    Valls-Ontanon, Adaia
    Hernandez-Alfaro, Federico
    JOURNAL OF CRANIOFACIAL SURGERY, 2019, 30 (08) : 2555 - 2559
  • [3] Semi-automated three-dimensional volumetric evaluation of mandibular condyles
    Gülay Altan Şallı
    Zeynep Öztürkmen
    Oral Radiology, 2021, 37 : 66 - 73
  • [4] Semi-automated three-dimensional volumetric evaluation of mandibular condyles
    Altan Salli, Gulay
    Ozturkmen, Zeynep
    ORAL RADIOLOGY, 2021, 37 (01) : 66 - 73
  • [5] Three-dimensional semi-automated segmentation of carotid atherosclerosis from three-dimensional ultrasound images
    Ukwatta, E.
    Awad, J.
    Buchanan, D.
    Parraga, G.
    Fenster, A.
    MEDICAL IMAGING 2012: COMPUTER-AIDED DIAGNOSIS, 2012, 8315
  • [6] Semi-automated software for the three-dimensional delineation of complex vascular networks
    Barber, PR
    Vojnovic, B
    Ameer-Beg, SM
    Hodgkiss, RJ
    Tozer, GM
    Wilson, J
    JOURNAL OF MICROSCOPY, 2003, 211 : 54 - 62
  • [7] Semi-automated protocol to quantify and characterize fluorescent three-dimensional vascular images
    Xie, Danny F.
    Crouzet, Christian
    Lopresti, Krystal
    Wang, Yuke
    Robinson, Christopher
    Jones, William
    Muqolli, Fjolla
    Fang, Chuo
    Cribbs, David H.
    Fisher, Mark
    Choi, Bernard
    PLOS ONE, 2024, 19 (05):
  • [8] SEMI-AUTOMATED QUANTIFICATION OF TRICUSPID VALVE DYNAMICS AND STRUCTURE IS FEASIBLE IN CHILDREN USING THREE-DIMENSIONAL ECHOCARDIOGRAPHY
    Craft, Mary
    Li, Ling
    Addetia, Karima
    Veronesi, Federico
    Danford, David
    Muraru, Denisa
    Kutty, Shelby
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2018, 71 (11) : 1546 - 1546
  • [9] Analysis of acetabular orientation and femoral anteversion using images of three-dimensional reconstructed bone models
    Jaeyeong Park
    Jun-Young Kim
    Hyun Deok Kim
    Young Cheol Kim
    Anna Seo
    Minkyu Je
    Jong Uk Mun
    Bia Kim
    Il Hyung Park
    Shin-Yoon Kim
    International Journal of Computer Assisted Radiology and Surgery, 2017, 12 : 855 - 864
  • [10] Reproducibility of Semi-automated Three-dimensional Volumetric Analysis using Cardiac Computed Tomography in Patients With Left Ventricular Assist Device
    Gill, Gauravpal S.
    Weissman, Gaby
    Meirovich, Yael F.
    Medvedofsky, Diego
    Mohammed, Selma F.
    Waksman, Ron
    Garcia-Garcia, Hector M.
    CARDIOVASCULAR REVASCULARIZATION MEDICINE, 2019, 20 (05) : 381 - 386