Low dose CBCT reconstruction via prior contour based total variation (PCTV) regularization: a feasibility study

被引:22
作者
Chen, Yingxuan [1 ]
Yin, Fang-Fang [1 ,2 ,3 ]
Zhang, Yawei [2 ]
Zhang, You [1 ]
Ren, Lei [1 ,2 ]
机构
[1] Duke Univ, Med Phys Grad Program, 2424 Erwin Rd,Suite 101, Durham, NC 27705 USA
[2] Duke Univ, Med Ctr, Dept Radiat Oncol, DUMC Box 3295, Durham, NC 27710 USA
[3] Duke Kunshan Univ, Med Phys Grad Program, Kunshan 215316, Jiangsu, Peoples R China
基金
美国国家卫生研究院;
关键词
-beam CT; total variation; edge preserving; prior image; low dose; compressed sensing; image reconstruction; BEAM COMPUTED-TOMOGRAPHY; CT RECONSTRUCTION; IMAGE-RECONSTRUCTION; CLINICAL-EVALUATION; PRIOR INFORMATION; PROJECTION DATA; DEFORMATION; FRAMEWORK; 4D-CBCT;
D O I
10.1088/1361-6560/aab68d
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Purpose: compressed sensing reconstruction using total variation (TV) tends to over-smooth the edge information by uniformly penalizing the image gradient. The goal of this study is to develop a novel prior contour based TV (PCTV) method to enhance the edge information in compressed sensing reconstruction for CBCT. Methods: the edge information is extracted from prior planning-CT via edge detection. Prior CT is first registered with on-board CBCT reconstructed with TV method through rigid or deformable registration. The edge contours in prior-CT is then mapped to CBCT and used as the weight map for TV regularization to enhance edge information in CBCT reconstruction. The PCTV method was evaluated using extended-cardiac-torso (XCAT) phantom, physical CatPhan phantom and brain patient data. Results were compared with both TV and edge preserving TV (EPTV) methods which are commonly used for limited projection CBCT reconstruction. Relative error was used to calculate pixel value difference and edge cross correlation was defined as the similarity of edge information between reconstructed images and ground truth in the quantitative evaluation. Results: compared to TV and EPTV, PCTV enhanced the edge information of bone, lung vessels and tumor in XCAT reconstruction and complex bony structures in brain patient CBCT. In XCAT study using 45 half-fan CBCT projections, compared with ground truth, relative errors were 1.5%, 0.7% and 0.3% and edge cross correlations were 0.66, 0.72 and 0.78 for TV, EPTV and PCTV, respectively. PCTV is more robust to the projection number reduction. Edge enhancement was reduced slightly with noisy projections but PCTV was still superior to other methods. PCTV can maintain resolution while reducing the noise in the low mAs CatPhan reconstruction. Low contrast edges were preserved better with PCTV compared with TV and EPTV. Conclusion: PCTV preserved edge information as well as reduced streak artifacts and noise in low dose CBCT reconstruction. PCTV is superior to TV and EPTV methods in edge enhancement, which can potentially improve the localization accuracy in radiation therapy.
引用
收藏
页数:16
相关论文
共 38 条
[1]   A few-view reweighted sparsity hunting (FRESH) method for CT image reconstruction [J].
Chang, Ming ;
Li, Liang ;
Chen, Zhiqiang ;
Xiao, Yongshun ;
Zhang, Li ;
Wang, Ge .
JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2013, 21 (02) :161-176
[2]   Prior image constrained compressed sensing (PICCS): A method to accurately reconstruct dynamic CT images from highly undersampled projection data sets [J].
Chen, Guang-Hong ;
Tang, Jie ;
Leng, Shuai .
MEDICAL PHYSICS, 2008, 35 (02) :660-663
[3]  
Chen Y, 2017, MED PHYS, V44, P3033
[4]   dPIRPLE: a joint estimation framework for deformable registration and penalized-likelihood CT image reconstruction using prior images [J].
Dang, H. ;
Wang, A. S. ;
Sussman, Marc S. ;
Siewerdsen, J. H. ;
Stayman, J. W. .
PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (17) :4799-4826
[5]   Advances in image-guided radiation therapy [J].
Dawson, Laura A. ;
Jaffray, David A. .
JOURNAL OF CLINICAL ONCOLOGY, 2007, 25 (08) :938-946
[6]   PRACTICAL CONE-BEAM ALGORITHM [J].
FELDKAMP, LA ;
DAVIS, LC ;
KRESS, JW .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1984, 1 (06) :612-619
[7]  
Guo W., 2010, P SPIE VISUAL COMMUN
[8]   Estimating 4D-CBCT from prior information and extremely limited angle projections using structural PCA and weighted free-form deformation for lung radiotherapy [J].
Harris, Wendy ;
Zhang, You ;
Yin, Fang-Fang ;
Ren, Lei .
MEDICAL PHYSICS, 2017, 44 (03) :1089-1104
[9]   Monte Carlo-calculated patient organ doses from kV-cone beam CT in image-guided radiation therapy [J].
Hioki, Kazunari ;
Araki, Fujio ;
Ohno, Takeshi ;
Tomiyama, Yuuki ;
Nakaguchi, Yuji .
BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2015, 1 (02)
[10]  
Huang J, 2013, PLOS ONE, V8, DOI [10.1371/journal.pone.0068688, 10.1371/journal.pone.0079709]