A criterion for the reliable use of MRI-only radiotherapy

被引:79
|
作者
Korsholm, Marie E. [1 ]
Waring, Line W. [2 ,3 ]
Edmund, Jens M. [1 ]
机构
[1] Univ Copenhagen, Herlev Hosp, Dept Oncol, Radiotherapy Res Unit 52AA, DK-2730 Herlev, Denmark
[2] Univ Copenhagen, Fac Hlth Sci, Dept Biomed Sci, Copenhagen, Denmark
[3] Univ Copenhagen, Fac Hlth Sci, Danish Natl Res Fdn Ctr Cardiac Arrhythmia, Copenhagen, Denmark
关键词
DOSE CALCULATION; CT; REGISTRATION; UNCERTAINTIES; PROSTATE; SYSTEM;
D O I
10.1186/1748-717X-9-16
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background: MRI-only radiotherapy will eliminate the systematic registration errors introduced when transferring MRI information to the CT. However, challenges concerning the missing information on electron density, necessary for dose calculation and patient setup on bony anatomy are introduced. This study presents a possible statistical approach to evaluate, if deviations based on MRI-only radiotherapy as compared to the CT based radiotherapy are acceptable. Methods: 18 head-and-neck, 21 prostate, 10 vesica and 8 pelvic patients were included in the study. Data from each patient contained a CT and a T2-weighted MRI scan, a structure set and a clinically approved CT based treatment plan, which was re-calculated with identical parameters on the density corrected MRI scans. A statistical analysis including a 95% confidence interval was performed in clinically relevant DVH points. Results: The mean differences in the investigated DVH points were in the order of 1.5% for the PTV and up to 4.2% for organs at risk. In addition, a proposed criterion of 2% dose difference in the PTV coverage for 95% of the patients was fulfilled for all diagnostic groups for a bulk segmented MRI in the DVH points, D-median and D-2%, while only head-and-neck and prostate further fulfilled the criterion in D-98%. Conclusion: Here, we suggested a method for establishing a reliable use of MRI-only radiotherapy. A population-based study comparing CT based dose calculations with those obtained on a suggested segmentation of MRI should be initiated and acceptable deviations in clinically relevant DVH points should be established. Such a population-based approach could form a part of the clinical commissioning of MRI-only radiotherapy.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] Evaluation of a synthetic-CT generation method for MRI-only head and neck cancer radiotherapy
    Riga, S.
    Carsana, C.
    Felisi, M.
    Sibio, D.
    Monti, A. F.
    Lizio, D.
    Pellegrini, R. G.
    Curto, D.
    Muti, G.
    Maigualca, O. E. Panchi
    Bortolato, B.
    Bracco, F.
    Vanzulli, A.
    Palazzi, M.
    Torresin, A.
    RADIOTHERAPY AND ONCOLOGY, 2022, 170 : S281 - S283
  • [32] MRI-only treatment planning: benefits and challenges
    Owrangi, Amir M.
    Greer, Peter B.
    Glide-Hurst, Carri K.
    PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (05):
  • [33] Abdominal Synthetic CT Reconstruction Using Intensity Projection Prior for MRI-Only Adaptive Radiotherapy
    Olberg, S.
    Chun, J.
    Choi, B.
    Park, I.
    Kim, H.
    Kim, T.
    Kim, J.
    Green, O.
    Park, J.
    MEDICAL PHYSICS, 2020, 47 (06) : E574 - E574
  • [34] Evaluation of MRI-only based online adaptive radiotherapy of abdominal region on MR-linac
    Nousiainen, Katri
    Santurio, Grichar Valdes
    Lundahl, Nils
    Cronholm, Rickard
    Siversson, Carl
    Edmund, Jens M.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2023, 24 (03):
  • [35] Evaluation of a multi-atlas CT synthesis approach for MRI-only radiotherapy treatment planning
    Guerreiro, F.
    Burgos, N.
    Dunlop, A.
    Wong, K.
    Petkar, I.
    Nutting, C.
    Harrington, K.
    Bhide, S.
    Newbold, K.
    Dearnaley, D.
    deSouza, N. M.
    Morgan, V. A.
    McClelland, J.
    Nill, S.
    Cardoso, M. J.
    Ourselin, S.
    Oelfke, U.
    Knopf, A. C.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2017, 35 : 7 - 17
  • [36] Patient-Specific Synthetic CT Generation for MRI-Only Prostate Radiotherapy Treatment Planning
    Yang, X.
    Lei, Y.
    Wang, T.
    Patel, P.
    Dhabaan, A.
    Jiang, X.
    Shim, H.
    Mao, H.
    Curran, W.
    Jani, A.
    Liu, T.
    MEDICAL PHYSICS, 2018, 45 (06) : E701 - E702
  • [37] A voxel-based investigation for MRI-only radiotherapy of the brain using ultra short echo times
    Edmund, Jens M.
    Kjer, Hans M.
    Van Leemput, Koen
    Hansen, Rasmus H.
    Andersen, Jon A. L.
    Andreasen, Daniel
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (23): : 7501 - 7519
  • [38] Feasibility Study of MRI-Only Proton Therapy Planning
    Spadea, M.
    Izquierdo, D.
    Catana, C.
    Collins-Fekete, C.
    Bortfeld, T.
    Seco, J.
    MEDICAL PHYSICS, 2015, 42 (06) : 3316 - 3317
  • [39] Identification and separation of rigid image registration error sources, demonstrated for MRI-only image guided radiotherapy
    Tyyger, M.
    Nix, M.
    Al-Qaisieh, B.
    Teo, M. T.
    Speight, R.
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2020, 6 (03)
  • [40] "sCT-Feasibility" - a feasibility study for deep learning-based MRI-only brain radiotherapy
    Grigo, Johanna
    Szkitsak, Juliane
    Hoefler, Daniel
    Fietkau, Rainer
    Putz, Florian
    Bert, Christoph
    RADIATION ONCOLOGY, 2024, 19 (01)