Biomechanical Comparison of Different Stabilization Constructs for Unstable Posterior Wall Fractures of Acetabulum. A Cadaveric Study

被引:10
|
作者
Zhang, Yuntong [1 ]
Tang, Yang [1 ]
Wang, Panfeng [1 ]
Zhao, Xue [1 ]
Xu, Shuogui [1 ]
Zhang, Chuncai [1 ]
机构
[1] Second Mil Med Univ, Changhai Hosp, Dept Orthopaed, Shanghai, Peoples R China
来源
PLOS ONE | 2013年 / 8卷 / 12期
关键词
INTERNAL-FIXATION; OPERATIVE TREATMENT; PLATE-FIXATION; OPEN REDUCTION; SCREWS; DISLOCATIONS; STRENGTH; COLUMN;
D O I
10.1371/journal.pone.0082993
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Purpose: Operative treatment of unstable posterior wall fractures of acetabulum has been widely recommended. This laboratory study was undertaken to evaluate static fixation strength of three common fixation constructs: interfragmentary screws alone, in combination with conventional reconstruction plate, or locking reconstruction plate. Methods: Six formalin-preserved cadaveric pelvises were used for this investigation. A posterior wall fracture was created along an arc of 40-90 degree about the acetabular rim. Three groups of different fixation constructs (two interfragmentary screws alone; two interfragmentary screws and a conventional reconstruction plate; two interfragmentary screws and a locking reconstruction) were compared. Pelvises were axial loaded with six cycles of 1500 N. Dislocation of superior and inferior fracture site was analysed with a multidirectional ultrasonic measuring system. Results: No statistically significant difference was found at each of the superior and inferior fracture sites between the three types of fixation. In each group, the vector dislocation at superior fracture site was significantly larger than inferior one. Conclusions: All those three described fixation constructs can provide sufficient stability for posterior acetabular fractures and allow early mobilization under experimental conditions. Higher posterior acetabular fracture line, transecting the weight-bearing surface, may indicate a substantial increase in instability, and need more stable pattern of fixation.
引用
收藏
页数:8
相关论文
共 22 条
  • [1] Modified Kocher-Langenbeck Approach for the Stabilization of Posterior Wall Fractures of the Acetabulum
    Magu, Narender Kumar
    Rohilla, Rajesh
    Arora, Sanjay
    More, Hament
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2011, 25 (04) : 243 - 249
  • [2] A biomechanical comparison of different fixation techniques for fractures of the acetabular posterior wall
    Wu, Xinbao
    INTERNATIONAL ORTHOPAEDICS, 2018, 42 (03) : 673 - 679
  • [3] Acetabulum Cup Stability in an Early Weight-Bearing Cadaveric Model of Geriatric Posterior Wall Fractures
    Marmor, Meir
    Knox, Riley
    Huang, Adrian
    Herfat, Safa
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2020, 34 (01) : 55 - 61
  • [4] Comparison of three different fixation constructs for radial neck fractures: a biomechanical study
    Chen, Hongwei
    Wu, Dengying
    Pan, Tianlong
    Pan, Jun
    Zhang, Rui
    Shi, Xuchao
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2017, 12
  • [5] Precontoured buttress plate vs reconstruction plate for acetabulum posterior wall fractures: A biomechanical study
    Altun, Guray
    Saka, Gursel
    Demir, Teyfik
    Elibol, Fatma Kubra Erbay
    Polat, Mehmet Orcun
    WORLD JOURNAL OF ORTHOPEDICS, 2019, 10 (05): : 219 - 227
  • [6] Biomechanical Comparison of Two Locking Plate Constructs for the Stabilization of Feline Tibial Fractures
    Hottmann, Natasha M.
    Johnson, Matthew D.
    Banks, Scott A.
    Tuyn, David
    Lewis, Daniel D.
    VETERINARY AND COMPARATIVE ORTHOPAEDICS AND TRAUMATOLOGY, 2020, 33 (02) : 89 - 95
  • [7] Talon cannulated compression device as an alternative in the fixation of acetabulum posterior column fractures: A biomechanical study
    Sibar, Kemal
    Alemdaroglu, Kadir Bahadir
    Elibol, Fatma Kubra Erbay
    Caliskan, Ozde Irem
    Demir, Teyfik
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2023, 54 (10):
  • [8] Biomechanical comparison of different external fixator configurations for stabilization of supracondylar humerus fractures in children
    Hohloch, Lisa
    Konstantinidis, Lukas
    Wagner, Ferdinand C.
    Strohm, Peter C.
    Suedkamp, Norbert P.
    Reising, Kilian
    CLINICAL BIOMECHANICS, 2016, 32 : 118 - 123
  • [9] Biomechanical Comparison of Fixation Methods for Posterior Wall Fractures of the Acetabulum: Conventional Reconstruction Plate vs. Spring Plate vs. Variable Angle Locking Compression Plate
    Chung, Hoejeong
    Sohn, Hoon-Sang
    Oh, Jong-Keon
    Lee, Sangho
    Kim, Doosup
    MEDICINA-LITHUANIA, 2024, 60 (06):
  • [10] Comparative Study of W-Shaped Angular Plate and Reconstruction Plate in Treating Posterior Wall Fractures of the Acetabulum
    Zhang, Qi
    Chen, Wei
    Wu, Xiaobo
    Su, Yanling
    Hou, Zhiyong
    Zhang, Yingze
    PLOS ONE, 2014, 9 (03):