Patient-specific total knee arthroplasty: the importance of planning by the surgeon

被引:61
作者
Pietsch, M. [1 ]
Djahani, O. [1 ]
Hochegger, M. [1 ]
Plattner, F. [1 ]
Hofmann, S. [1 ]
机构
[1] Gen & Orthopaed Hosp Stolzalpe, Dept Orthopaed Surg, A-8852 Stolzalpe, Austria
关键词
Patient-specific instruments; Custom-fit; Total knee arthroplasty; INITIAL-EXPERIENCE; ALIGNMENT; TIBIA; AXIS;
D O I
10.1007/s00167-013-2624-7
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The purpose of the study was to evaluate the accuracy of the planning of the patient-specific pin guides in total knee arthroplasty (TKA). This planning was performed primarily by a technician of the company and offered to the surgeon. All parameters of the implantation can either be modified or accepted by the surgeon. The hypothesis was that the plan needs preoperative intervention by the surgeon. A prospective study in 50 patients was carried out. All patients received the same posterior-stabilised implant with patient-specific instrumentation. All surgical parameters (coronal, sagittal, rotational alignment, femoral and tibial resection levels and implant sizes) were checked by the orthopaedic surgeon and changed if necessary. Preoperatively, the femoral size was changed in 8 patients (16 %), the femoral flexion in 23 patients (46 %), the femoral shift in 34 patients (68 %), the tibial size in 24 patients (48 %) and the tibial rotation in all patients. The epicondylar axis was accepted in 47 patients (94 %) in the technician plan. Mean planning time was 8 +/- A 4 min. Intraoperatively, the femoral anterior-posterior size was in 50 patients (100 %) the same as in the surgeon and in 42 patients (84 %) the same as in the technician plan (p = 0.003). The tibial component implanted was in 42 patients (84 %) the same as in the surgeon and in 19 patients (38 %) the same as in the technician plan (p < 0.0001). A femoral distal recut was necessary in 31 patients (62 %) and a change of the tibial proximal cut in 17 patients (34 %) during surgery. Intraoperatively, no changes of the femoral and tibial alignment, the femoral anterior-posterior size, the femoral flexion, the femoral shift, the femoral and tibial rotation were necessary. Postoperatively, the coronal mechanical overall axis was within +/- 3A degrees in 47 patients (94 %) with a maximum deviation of 5.6A degrees. Significant changes of the technician plan were necessary to get an accurate preoperative plan. Intraoperative changes were significant less compared to the surgeon than to the technician plan. No major changes (alignment, femoral anterior-posterior size and rotation) of the surgeon plan were necessary. Surgeons using patient-specific pin guides in TKA may verify the default plan provided by the technician. A blind reply on the technician plan may be not recommended. Therapeutic study, Level III.
引用
收藏
页码:2220 / 2226
页数:7
相关论文
共 21 条
[1]   An anteroposterior axis of the tibia for total knee arthroplasty [J].
Akagi, M ;
Oh, M ;
Nonaka, T ;
Tsujimoto, H ;
Asano, T ;
Hamanishi, C .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2004, (420) :213-219
[2]   Custom-Fit Total Knee Arthroplasty: Our Initial Experience in 32 Knees [J].
Bali, Kamal ;
Walker, Peter ;
Bruce, Warwick .
JOURNAL OF ARTHROPLASTY, 2012, 27 (06) :1149-1154
[3]   Alignment in total knee arthroplasty -: A comparison of computer-assisted surgery with the conventional technique [J].
Bäthis, H ;
Perlick, L ;
Tingart, M ;
Lüring, C ;
Zurakowski, D ;
Grifka, J .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2004, 86B (05) :682-687
[4]   Malrotation causing patellofemoral complications after total knee arthroplasty [J].
Berger, RA ;
Crossett, LS ;
Jacobs, JJ ;
Rubash, HE .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1998, (356) :144-153
[5]   Randomized control trial comparing radiographic total knee arthroplasty implant placement using computer navigation versus conventional technique [J].
Chin, PL ;
Yang, KY ;
Yeo, SJ ;
Lo, NN .
JOURNAL OF ARTHROPLASTY, 2005, 20 (05) :618-626
[6]   The anatomical tibial axis - Reliable rotational orientation in knee replacement [J].
Cobb, J. P. ;
Dixon, H. ;
Dandachli, W. ;
Iranpour, F. .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2008, 90B (08) :1032-1038
[7]   Computer-assisted minimally invasive total knee arthroplasty compared with standard total knee arthroplasty [J].
Dutton, Andrew Quoc ;
Yeo, Seng-Jin ;
Yang, Kuang-Ying ;
Lo, Ngai-Nung ;
Chia, Kui-Un ;
Chong, Hwei-Chi .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2008, 90A (01) :2-9
[8]  
Heyse TJ, 2012, KNEE, DOI [10.1016/s09680160(12)00198-6, DOI 10.1016/S09680160(12)00198-6]
[9]   Results of an initial experience with custom-fit positioning total knee arthroplasty in a series of 48 patients [J].
Howell, Stephen M. ;
Kuznik, Kyle ;
Hull, Maury L. ;
Siston, Robert A. .
ORTHOPEDICS, 2008, 31 (09) :857-863
[10]   Anatomic rotational relationships of the proximal tibia, distal femur, and patella - Implications for rotational alignment in total knee arthroplasty [J].
Incavo, SJ ;
Coughlin, KM ;
Pappas, C ;
Beynnon, BD .
JOURNAL OF ARTHROPLASTY, 2003, 18 (05) :643-648