Comparative Voltammetric Analysis of Adenine and Xanthine on a Pencil Graphite Electrode in the Presence of Copper Ions

被引:0
作者
Navratil, Rudolf [1 ]
Pilarova, Iveta [1 ,2 ]
Jelen, Frantisek [3 ]
Trnkova, Libuse [1 ,4 ]
机构
[1] Masaryk Univ, Fac Sci, Dept Chem, CZ-62500 Brno, Czech Republic
[2] Masaryk Univ, CEITEC MU, CZ-62500 Brno, Czech Republic
[3] Inst Biophys AS CR, Vvi, CZ-61265 Brno, Czech Republic
[4] Univ Technol, CEITEC, CZ-61600 Brno, Czech Republic
关键词
Oxidation of purines; Pencil graphite electrode; Linear sweep voltammetry; Differential pulse voltammetry; Elimination voltammetry with linear scan; ADSORPTIVE STRIPPING VOLTAMMETRY; ELIMINATION VOLTAMMETRY; ANODIC VOLTAMMETRY; CARBON ELECTRODES; CYTOSINE SIGNALS; PURINE-BASES; URIC-ACID; HYPOXANTHINE; OXIDATION; DNA;
D O I
暂无
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
This work compares voltammetric responses of adenine (Ade) and xanthine (Xan) on a pencil graphite electrode (PeGE) in the presence of copper ions. For electroanalytical monitoring linear sweep voltammetry (LSV) in connection with elimination procedure (EVLS - elimination voltammetry with linear scan), differential pulse voltammetry (DPV), and constant current potentiostatic stripping analysis (CPSA) were used. Both substances are oxidized on PeGE providing simple oxidation peaks in the absence of Cu(II) at about 0.8 V (Xan) and 1.1 V (Ade). Electrochemically produced Cu(I) ions give rise to new oxidation peaks corresponding to the oxidation of a sparingly soluble Cu(I)-purine complex at less positive potentials (similar to 0.45 V) while the former oxidation purine peaks are increased. Compared to Ade the oxidative signal of Xan is split into two peaks depending on scan rate. Peak-counterpeak EVLS signals reflect the charge transfer processes proceeding in an adsorbed state, and this fact confirms the suggested mechanism of both electrode processes. The splitting of xanthine oxidation signal was tested by means of a potential jump from -0.15 V to 0.65 V. The effect of scan rate, pH and concentration of Cu and ligands was studied in order to evaluate not only the nature of the additional Xan oxidation peak but also to optimize the best conditions for electroanalytical determination of Ade and Xan in mixtures.
引用
收藏
页码:4397 / 4408
页数:12
相关论文
共 50 条
[41]   Application of a pencil graphite electrode for voltammetric simultaneous determination of ascorbic acid, norepinephrine, and uric acid in real samples [J].
Levent, Abdulkadir ;
Onal, Gunay .
TURKISH JOURNAL OF CHEMISTRY, 2018, 42 (02) :460-471
[42]   Highly sensitive voltammetric electrode for the trace measurement of methyldopa based on a pencil graphite modified with phosphomolibdate/graphene oxide [J].
Dehnavi, Azar ;
Soleymanpour, Ahmad .
MICROCHEMICAL JOURNAL, 2020, 157
[43]   Reaction and nucleation mechanisms of copper electrodeposition on disposable pencil graphite electrode [J].
Majidi, M. R. ;
Asadpour-Zeynali, K. ;
Hafezi, B. .
ELECTROCHIMICA ACTA, 2009, 54 (03) :1119-1126
[44]   Highly sensitive voltammetric determination of the fungicide fenhexamid using a cost-effective and disposable pencil graphite electrode [J].
Ersan, Teslime ;
Dilgin, Didem Giray ;
Oral, Ayhan ;
Skrzypek, Slawomira ;
Brycht, Mariola ;
Dilgin, Yusuf .
MICROCHIMICA ACTA, 2024, 191 (12)
[45]   Sensitive Adsorptive Voltammetric Method for Determination of Bisphenol A by Gold Nanoparticle/Polyvinylpyrrolidone-Modified Pencil Graphite Electrode [J].
Yaman, Yesim Tugce ;
Abaci, Serdar .
SENSORS, 2016, 16 (06)
[46]   Green Voltammetric Detection of Ophthalmic Drug Nepafenac Using Pencil Graphite Electrode as a Responsive Disposable Electrochemical Sensor [J].
Ersali, Huseyin ;
Levent, Abdulkadir .
CHEMISTRYSELECT, 2024, 9 (37)
[47]   Simultaneous differential pulse voltammetric analysis of guanine and adenine using graphitized carbon nanofibers modified electrode [J].
Thangaraj, Rajendiran ;
Kumar, Annamalai Senthil .
JOURNAL OF THE INDIAN CHEMICAL SOCIETY, 2015, 92 (04) :493-496
[48]   Electrochemical evaluation and adsorptive stripping voltammetric determination of capsaicin or dihydrocapsaicin on a disposable pencil graphite electrode [J].
Yardim, Yavuz ;
Senturk, Zuhre .
TALANTA, 2013, 112 :11-19
[49]   Voltammetric Determination of Acrylamide Using Coal Tar Pitch Modified Pencil Graphite Electrode by SWV [J].
Şeyma Korkmaz ;
Wael Bosnali ;
İbrahim Ender Mülazımoğlu ;
Ayşen Demir Mülazımoğlu .
Food Analytical Methods, 2023, 16 :1738-1745
[50]   Voltammetric Determination of Acrylamide Using Coal Tar Pitch Modified Pencil Graphite Electrode by SWV [J].
Korkmaz, Seyma ;
Bosnali, Wael ;
Mulazimoglu, Ibrahim Ender ;
Mulazimoglu, Aysen Demir .
FOOD ANALYTICAL METHODS, 2023, 16 (11-12) :1738-1745