Iterative tomographic reconstruction with TV prior for low-dose CBCT dental imaging

被引:8
作者
Friot--Giroux, Louise [1 ]
Peyrin, Francoise [1 ]
Maxim, Voichita [1 ]
机构
[1] Univ Claude Bernard Lyon 1, Univ Lyon, INSA Lyon, CNRS,Inserm,CREATIS UMR 5220,U1294, F-69620 Lyon, France
关键词
CBCT; dental imaging; iterative reconstruction; CONE-BEAM CT; X-RAY TOMOGRAPHY; COMPUTED-TOMOGRAPHY; MAXIMUM-LIKELIHOOD; ORDERED SUBSETS; ALGORITHM; EMISSION; REGULARIZATION; NOISE; ART;
D O I
10.1088/1361-6560/ac950c
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective. Cone-beam computed tomography is becoming more and more popular in applications such as 3D dental imaging. Iterative methods compared to the standard Feldkamp algorithm have shown improvements in image quality of reconstruction of low-dose acquired data despite their long computing time. An interesting aspect of iterative methods is their ability to include prior information such as sparsity-constraint. While a large panel of optimization algorithms along with their adaptation to tomographic problems are available, they are mainly studied on 2D parallel or fan-beam data. The issues raised by 3D CBCT and moreover by truncated projections are still poorly understood. Approach. We compare different carefully designed optimization schemes in the context of realistic 3D dental imaging. Besides some known algorithms, SIRT-TV and MLEM, we investigate the primal-dual hybrid gradient (PDHG) approach and a newly proposed MLEM-TV optimizer. The last one is alternating EM steps and TV-denoising, combination not yet investigated for CBCT. Experiments are performed on both simulated data from a 3D jaw phantom and data acquired with a dental clinical scanner. Main results. With some adaptations to the specificities of CBCT operators, PDHG and MLEM-TV algorithms provide the best reconstruction quality. These results were obtained by comparing the full-dose image with a low-dose image and an ultra low-dose image. Significance. The convergence speed of the original iterative methods is hampered by the conical geometry and significantly reduced compared to parallel geometries. We promote the pre-conditioned version of PDHG and we propose a pre-conditioned version of the MLEM-TV algorithm. To the best of our knowledge, this is the first time PDHG and convergent MLEM-TV algorithms are evaluated on experimental dental CBCT data, where constraints such as projection truncation and presence of metal have to be jointly overcome.
引用
收藏
页数:21
相关论文
共 56 条
[1]   Learned Primal-Dual Reconstruction [J].
Adler, Jonas ;
Oktem, Ozan .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2018, 37 (06) :1322-1332
[2]   SIMULTANEOUS ALGEBRAIC RECONSTRUCTION TECHNIQUE (SART) - A SUPERIOR IMPLEMENTATION OF THE ART ALGORITHM [J].
ANDERSEN, AH ;
KAK, AC .
ULTRASONIC IMAGING, 1984, 6 (01) :81-94
[3]  
[Anonymous], 2012, J Biomed Sci Eng, DOI [10.4236/jbise.2012.58052, DOI 10.4236/JBISE.2012.58052]
[4]   SOME PROXIMAL METHODS FOR POISSON INTENSITY CBCT AND PET [J].
Anthoine, Sandrine ;
Aujol, Jean-Francois ;
Boursier, Yannick ;
Melot, Clothilde .
INVERSE PROBLEMS AND IMAGING, 2012, 6 (04) :565-598
[5]   Truncation effect reduction for fast iterative reconstruction in cone-beam CT [J].
Aootaphao, Sorapong ;
Thongvigitmanee, Saowapak S. ;
Puttawibul, Puttisak ;
Thajchayapong, Pairash .
BMC MEDICAL IMAGING, 2022, 22 (01)
[6]   Using a flat-panel detector in high resolution cone beam CT for dental imaging [J].
Baba, R ;
Ueda, K ;
Okabe, M .
DENTOMAXILLOFACIAL RADIOLOGY, 2004, 33 (05) :285-290
[7]  
Banjak H., 2016, THESIS INSA LYON
[8]   Evaluation of noise and blur effects with SIRT-FISTA-TV reconstruction algorithm: Application to fast environmental transmission electron tomography [J].
Banjak, Hussein ;
Grenier, Thomas ;
Epicier, Thierry ;
Koneti, Siddardha ;
Roiban, Lucian ;
Gay, Anne-Sophie ;
Magnin, Isabelle ;
Peyrin, Francoise ;
Maxim, Voichita .
ULTRAMICROSCOPY, 2018, 189 :109-123
[9]   A Two-Stage Approach for Beam Hardening Artifact Reduction in Low-Dose Dental CBCT [J].
Bayaraa, Taigyntuya ;
Hyun, Chang Min ;
Jang, Tae Jun ;
Lee, Sung Min ;
Seo, Jin Keun .
IEEE ACCESS, 2020, 8 :225981-225994
[10]   Fast Gradient-Based Algorithms for Constrained Total Variation Image Denoising and Deblurring Problems [J].
Beck, Amir ;
Teboulle, Marc .
IEEE TRANSACTIONS ON IMAGE PROCESSING, 2009, 18 (11) :2419-2434