A CFD model for the prediction of haemolysis in micro axial left ventricular assist devices

被引:19
作者
Carswell, D. [1 ]
McBride, D. [1 ]
Croft, T. N. [1 ]
Slone, A. K. [1 ]
Cross, M. [1 ]
Foster, G. [2 ]
机构
[1] Swansea Univ, Coll Engn, Civil & Computat Engn Ctr, Swansea SA2 8PP, W Glam, Wales
[2] Swansea Univ, Inst Life Sci, Calon Cardiotechnol Ltd, Swansea SA2 8PP, W Glam, Wales
关键词
Haemolysis; CFD; Blood pump; Axial flow; FINITE-ELEMENT-METHOD; BLOOD DAMAGE; FLOW PUMP; PERFORMANCE; SIMULATION;
D O I
10.1016/j.apm.2012.09.020
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
This paper describes the development and application of a computational model based upon Computational Fluid Dynamics (CFD) software simulation technology to predict haemolysis in micro Left Ventricular Assist Devices (mu LVAD). A CFD model, capturing the full three dimensional geometry of the device, together with an explicit representation of the rotating machinery based upon a rotating reference frame, is solved transiently. Mixed meshes with the order of a million elements are required to resolve the flow adequately and so to enable solutions in a reasonable time (e.g., 3 h) the model is solved on a high performance parallel cluster. Haemolysis is a measure of damage occurring in the blood and is conceived as accumulating as it passes through parts of the device where it encounters high shear forces. As such, the haemolysis model is based upon tracking the behaviour of particles released at the inlet throughout the flow domain and calculating the damage accumulated by each individual particle as it traverses the device. In order to ensure the model predictions of haemolysis are noise free from a statistically significant perspective then it is demonstrated that the number of particles to be tracked must exceed 20000 in any simulation experiment. Comparisons with experimental data from a companion paper demonstrate the effectiveness of the CFD simulation embedding the haemolysis model. (C) 2012 Elsevier Inc. All rights reserved.
引用
收藏
页码:4199 / 4207
页数:9
相关论文
共 32 条
  • [1] Arora D., 2005, Third MIT conference on computational fluid and solid mechanics, P578
  • [2] Arora D, 2005, THESIS RICE U
  • [3] A validated computational fluid dynamics model to estimate hemolysis in a rotary blood pump
    Arvand, A
    Hormes, M
    Reul, H
    [J]. ARTIFICIAL ORGANS, 2005, 29 (07) : 531 - 540
  • [4] A review of computational fluid dynamics analysis of blood pumps
    Behbahani, M.
    Behr, M.
    Hormes, M.
    Steinseifer, U.
    Arora, D.
    Coronado, O.
    Pasquali, M.
    [J]. EUROPEAN JOURNAL OF APPLIED MATHEMATICS, 2009, 20 : 363 - 397
  • [5] BLACKSHEAR PL, 1965, T AM SOC ART INT ORG, V11, P112
  • [6] Numerical investigation of the effects of the clearance gap between the inducer and impeller of an axial blood pump
    Chan, WK
    Wong, YW
    Ong, W
    Koh, SY
    Chong, V
    [J]. ARTIFICIAL ORGANS, 2005, 29 (03) : 250 - 258
  • [7] Numerical simulation of an axial blood pump
    Chua, Leok Poh
    Su, Boyang
    Lim, Tau Meng
    Zhou, Tongming
    [J]. ARTIFICIAL ORGANS, 2007, 31 (07) : 560 - 570
  • [8] Croft T.N., 2009, 1 INT C PAR DISTR GR
  • [9] Fraser KH, 2010, IFMBE PROC, V32, P548, DOI 10.1007/978-3-642-14998-6_140
  • [10] ESTIMATION OF SHEAR STRESS-RELATED BLOOD DAMAGE IN HEART-VALVE PROSTHESES - INVITRO COMPARISON OF 25 AORTIC VALVES
    GIERSIEPEN, M
    WURZINGER, LJ
    OPITZ, R
    REUL, H