Counterpoint to "Infrared cameras overestimate skin temperature during rewarming from cold exposure"

被引:5
作者
Havenith, George [1 ]
Lloyd, Alex B. [1 ]
机构
[1] Loughborough Univ, Environm Ergon Res Ctr, Sch Design & Creat Arts, Loughborough LE11 3TU, Leics, England
关键词
Infrared thermography; Skin temperature measurement; Instrument validity; Measurement error; THERMOGRAPHY;
D O I
10.1016/j.jtherbio.2020.102663
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
We evaluated the paper by Maley et al. (2020) in this journal "Infrared cameras overestimate skin temperature during rewarming from cold Exposure" for the evidence provided in support of its title and conclusions. Several methodological issues were identified as well as issues with the data interpretation: 1: Only one camera was used but a conclusion was made for 'cameras' in general; 2: The camera accuracy (+/- 2 degrees C) is too low to do a meaningful comparison without using local reference values or an on-site calibrator with higher accuracy; 3: Thermistor measurements are taken as a gold standard while issues such as temperature gradients and taping are known; 4: Both methods are not compared at the same location and a natural, physiological, gradient may be present between their locations; 5. The impact of the sensor and tape on delays in the change of the underlying tissue temperature is not considered; 6: Only a single pixel was used for the analysis, which has been shown to be problematic. We concluded that the paper by Maley et al. does not provide conclusive evidence that infrared cameras overestimate skin temperature during rewarming from cold exposure.
引用
收藏
页数:2
相关论文
共 14 条
[1]   Comparison of mean skin temperature using 'covered' versus 'uncovered' contact thermistors [J].
Buono, MJ ;
Ulrich, RL .
PHYSIOLOGICAL MEASUREMENT, 1998, 19 (02) :297-300
[2]  
Daanen HAM, 1997, THESIS
[3]   Measuring skin temperature before, during and after exercise: a comparison of thermocouples and infrared thermography [J].
Fernandes, Alex de Andrade ;
dos Santos Amorim, Paulo Roberto ;
Brito, Ciro Jose ;
de Moura, Anselmo Gomes ;
Moreira, Danilo Gomes ;
Amaral Costa, Carlos Magno ;
Sillero-Quintana, Manuel ;
Bouzas Marins, Joao Carlos .
PHYSIOLOGICAL MEASUREMENT, 2014, 35 (02) :189-203
[4]  
FLIR, 2020, MODE A320 CAM MAN, P105
[5]   Body mapping of thermoregulatory and perceptual responses of males and females running in the cold [J].
Fournet, Damien ;
Ross, Lindsey ;
Voelcker, Thomas ;
Redortier, Bernard ;
Havenith, George .
JOURNAL OF THERMAL BIOLOGY, 2013, 38 (06) :339-344
[6]   Skin temperature evaluation by infrared thermography: Comparison of image analysis methods [J].
Ludwig, N. ;
Formenti, D. ;
Gargano, M. ;
Alberti, G. .
INFRARED PHYSICS & TECHNOLOGY, 2014, 62 :1-6
[7]   Validity of contact skin temperature sensors under different environmental conditions with and without fabric coverage: characterisation and correction [J].
MacRae, Braid A. ;
Annaheim, Simon ;
Stampfli, Rolf ;
Spengler, Christina M. ;
Rossi, RenE M. .
INTERNATIONAL JOURNAL OF BIOMETEOROLOGY, 2018, 62 (10) :1861-1872
[8]   Infrared cameras overestimate skin temperature during rewarming from cold exposure [J].
Maley, Matthew J. ;
Hunt, Andrew P. ;
Bach, Aaron Je ;
Eglin, Clare M. ;
Costello, Joseph T. .
JOURNAL OF THERMAL BIOLOGY, 2020, 91
[9]   The effect of using different regions of interest on local and mean skin temperature [J].
Maniar, Nirav ;
Bach, Aaron J. E. ;
Stewart, Ian B. ;
Costello, Joseph T. .
JOURNAL OF THERMAL BIOLOGY, 2015, 49-50 :33-38
[10]   Effect of perspiration on skin temperature measurements by infrared thermography and contact thermometry during aerobic cycling [J].
Priego Quesada, Jose Ignacio ;
Martinez Guillamon, Natividad ;
Ortiz de Anda, Rosa Ma Cibrian ;
Psikuta, Agnes ;
Annaheim, Simon ;
Rossi, Rene Michel ;
Corberan Salvador, Jose Miguel ;
Perez-Soriano, Pedro ;
Salvador Palmer, Rosario .
INFRARED PHYSICS & TECHNOLOGY, 2015, 72 :68-76