Mechanical characteristics of the maxillary sinus Schneiderian membrane ex vivo

被引:19
作者
Insua, Angel [1 ,2 ]
Monje-Gil, Florencio [3 ]
Garcia-Caballero, Lucia [4 ]
Caballe-Serrano, Jordi [5 ]
Wang, Hom-Lay [1 ]
Monje, Alberto [1 ,6 ,7 ]
机构
[1] Univ Michigan, Sch Dent, Dept Periodont & Oral Med, Ann Arbor, MI 48109 USA
[2] Univ Santiago de Compostela, Sch Med & Dent, Dept Oral Surg & Oral Med, Entrerrios S-N, Santiago De Compostela 15782, Spain
[3] Hosp Infanta Cristina, Dept Oral & Maxillofacial Surg, Badajoz, Spain
[4] Univ Santiago de Compostela, Hlth Res Inst Santiago de Compostela IDIS, Med Surg Dent Res Grp OMEQUI, Santiago De Compostela, Spain
[5] Univ Int Catalunya, Dept Oral & Maxillofacial Surg, Barcelona, Spain
[6] Univ Bern, ZMK Sch Dent, Dept Oral Surg & Stomatol, Bern, Switzerland
[7] Univ Int Catalunya, Dept Periodontol, Barcelona, Spain
关键词
Dental implants; Grafting; Bone; Alveolar ridge augmentation; Maxillary sinus floor augmentation; FLOOR ELEVATION PROCEDURES; CLINICAL-IMPLICATIONS; AUGMENTATION; IMPLANTS; PERFORATION; THICKNESS; SURVIVAL; COMBINATION; SUCCESS;
D O I
10.1007/s00784-017-2201-4
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
It has been speculated that certain Schneiderian membrane thickness (SMT) might be more prone to perforation. This investigation was aimed at studying the mechanical characteristics of the Schneiderian membrane under one- and two-dimensional tests and their correlation to the histological SMT in human samples. Sixteen Schneiderian membranes were collected from 11 cadaver heads treated with Thiel's embalming method. The samples were processed and analyzed clinically and histologically. One-dimensional maximum elongation until perforation and two-dimensional resistance to ball penetration were performed after the biopsy. Data was analyzed by using the Wilcoxon rank test and the Spearman's rank correlation. The histological SMT was 1.36 +/- 0.42 mm, whereas the clinical thickness was 0.27 +/- 0.21 mm, yielding statistical significance (p = 0.000). The resistance under ball penetration was 0.59 +/- 0.43 N and the mean maximum elongation in the one-dimension test 11.19 +/- 7.14 mm. Expressed in percentage, the mean stretch was 241.36 +/- 227.97% (range 31.5 up to 947%). A weak positive correlation was found between the ball penetration test and the SMT (r = 0.10, p = 0.711), while a weak negative correlation was found between stretching test and the SMT (r = -0.021, p = 0.94). Mechanical tests seem to indicate that SMT might not significantly predispose to Schneiderian membrane perforation. Hence, other anatomical and operator's factors should be considered of surpassing importance. Thinner SM might be more prone to perforation when detaching it from the maxillary sinus antrum; however, a thick membrane is not prevented to tear, as their resistance under elastic forces is not higher than thinner ones.
引用
收藏
页码:1139 / 1145
页数:7
相关论文
共 50 条
  • [41] Risk Factor Analysis Affecting Sinus Membrane Perforation During Lateral Window Maxillary Sinus Elevation Surgery
    Krennmair, Stefan
    Malek, Michael
    Forstner, Thomas
    Krennmair, Gerald
    Weinlaender, Michael
    Hunger, Stefan
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2020, 35 (04) : 789 - 798
  • [42] Sinus floor elevation in sites with a perforated schneiderian membrane: What is the effect of placing a collagen membrane in a rabbit model?
    Lim, Hyun-Chang
    Son, Yeojin
    Hong, Ji-Youn
    Shin, Seung-Il
    Jung, Ui-Won
    Chung, Jong-Hyuk
    CLINICAL ORAL IMPLANTS RESEARCH, 2018, 29 (12) : 1202 - 1211
  • [43] Sinus floor elevation outcomes following perforation of the Schneiderian membrane. An experimental study in sheep
    Favero, Vittorio
    Lang, Niklaus P.
    Canullo, Luigi
    Urbizo Velez, Joaquin
    Bengazi, Franco
    Botticelli, Daniele
    CLINICAL ORAL IMPLANTS RESEARCH, 2016, 27 (02) : 233 - 240
  • [44] Histological and Histomorphometric Evaluation of Applying a Bioactive Advanced Platelet-Rich Fibrin to a Perforated Schneiderian Membrane in a Maxillary Sinus Elevation Model
    Xin, Liangjing
    Yuan, Shuai
    Mu, Zhixiang
    Li, Dize
    Song, Jinlin
    Chen, Tao
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2020, 8
  • [45] LATERAL SINUS FLOOR ELEVATION IN CASES OF AN INTACT AND PERFORATED SCHNEIDERIAN MEMBRANE
    Fakih, Khodor
    Edreva, Mariya
    Stoichkov, Biser
    Fakih, Yana
    COMPTES RENDUS DE L ACADEMIE BULGARE DES SCIENCES, 2024, 77 (03): : 459 - 466
  • [46] Influences of Schneiderian membrane conditions on the early outcomes of osteotome sinus floor elevation technique: a prospective cohort study in the healing period
    Qin, Lei
    Lin, Sheng-xiao
    Guo, Zheng-Ze
    Zhao, Ningbo
    Song, Ying-Liang
    Xie, Chao
    Li, De-Hua
    CLINICAL ORAL IMPLANTS RESEARCH, 2017, 28 (09) : 1074 - 1081
  • [47] Maxillary sinus membrane elevation and coagulum compared with maxillary sinus floor augmentation and a composite graft: A 1-year single-blinded randomized controlled trial
    Starch-Jensen, Thomas
    Bruun, Niels Henrik
    Spin-Neto, Rubens
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2023, 25 (06) : 1056 - 1068
  • [48] Comparison of biomechanical characteristics of the Schneiderian membrane with different transcrestal sinus floor elevation techniques using three-dimensional finite element analysis
    Lin, Xi
    Xu, Siqi
    Chen, Lijuan
    Que, Guoying
    BMC ORAL HEALTH, 2025, 25 (01):
  • [49] Maxillary sinus membrane perforation rate utilizing osseodensification-mediated transcrestal sinus floor elevation: A multicenter clinical study
    Mazor, Ziv
    Gaspar, Joao
    Silva, Robert
    Pohl, Snjezana
    Gandhi, Yazad
    Huwais, Salah
    Bergamo, Edmara Tatiely Pedroso
    Bonfante, Estevam Augusto
    Neiva, Rodrigo
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2024, 26 (06) : 1172 - 1180
  • [50] Schneiderian Membrane Thickness and Clinical Implications for Sinus Augmentation: A Systematic Review and Meta-Regression Analyses
    Monje, Alberto
    Diaz, Karla Tatiana
    Aranda, Luisiana
    Insua, Angel
    Garcia-Nogales, Agustin
    Wang, Hom-Lay
    JOURNAL OF PERIODONTOLOGY, 2016, 87 (08) : 888 - 899