Lateral Position With Gantry Tilt Further Improves Computed Tomography Image Quality Reconstructed Using Single-Energy Metal Artifact Reduction Algorithm in the Oral Cavity

被引:2
作者
Onodera, Maki [1 ]
Aratani, Kazunori [2 ]
Shonai, Takaharu [3 ]
Ogura, Keishi [4 ]
Kamo, Ken-ichi [5 ]
Ogi, Kazuhiro [6 ]
Kondo, Atsushi [7 ]
Hatakenaka, Masamitsu [1 ]
机构
[1] Sapporo Med Univ, Sch Med, Dept Diagnost Radiol, Sapporo, Hokkaido, Japan
[2] ART Reading LLC, Sapporo, Hokkaido, Japan
[3] Sapporo Teishinkai Hosp, Dept Diagnost Radiol, Sapporo, Hokkaido, Japan
[4] Sapporo Med Univ Hosp, Div Radiol & Nucl Med, Sapporo, Hokkaido, Japan
[5] Sapporo Med Univ, Sch Med, Liberal Arts & Sci, Ctr Med Educ, Sapporo, Hokkaido, Japan
[6] Sapporo Med Univ, Sch Med, Dept Oral Surg, Sapporo, Hokkaido, Japan
[7] Sapporo Med Univ, Sch Med, Dept Otolaryngol, Sapporo, Hokkaido, Japan
关键词
artifacts; image enhancement; metals; oral cavity; patient positioning; CT; LENS; HIP; EYE;
D O I
10.1097/RCT.0000000000001029
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective To assess the limitations of single-energy metal artifact reduction algorithm in the oral cavity and evaluate the availability of a solution by setting the patient in a lateral position (LP) with the use of a gantry tilt (GT). Methods We analyzed 88 patients with dental metals retrospectively in study 1, and 74 patients prospectively in study 2. Patients were classified: metal I with dental metals in 1 region, metal II in 2 regions, and metal III in 3 regions. Patients underwent neck computed tomography examinations in a supine position (SP) in study 1, and 2 positions, an LP with a GT and an SP, in study 2. All images were reconstructed with this algorithm. Image quality was scored using a 4-point scale: 1 = severe artifact, 2 = moderate artifact, 3 = slight artifact, 4 = no artifact. The scores were compared between metal I, metal II, and metal III using the Mann-WhitneyUtest in study 1, and between an LP with a GT and an SP using the Wilcoxon signed ranks test in study 2. Results The scores outside the dental arch were significantly higher in metal I than in metal II and metal III (3.0 +/- 0.6 vs 2.3 +/- 0.5 vs 2.2 +/- 0.4;P< 0.0001 for metal I vs metal II and for metal I vs metal III) and significantly higher in an LP with a GT than an SP (3.2 +/- 0.4 vs 2.3 +/- 0.4;P< 0.0001). Conclusions Single-energy metal artifact reduction algorithm could reduce metal artifacts adequately in patients with dental metals in 1 region, but not in 2 or more regions. However, even for the latter, combination of this algorithm and an LP with a GT could further improve the image quality.
引用
收藏
页码:553 / 558
页数:6
相关论文
共 18 条
  • [1] Diagnostic accuracy of state-of-the-art MDCT scanners without gantry tilt in patients with oral and oropharyngeal cancer
    Bannas, Peter
    Habermann, Christian R.
    Jung, Caroline
    Bley, Thorsten A.
    Ittrich, Harald
    Adam, Gerhard
    Koops, Andreas
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (12) : 3947 - 3952
  • [2] Chang YB, 2012, IEEE NUCL SCI CONF R, P3426
  • [3] A newly-developed metal artifact reduction algorithm improves the visibility of oral cavity lesions on 320-MDCT volume scans
    Funama, Yoshinori
    Taguchi, Katsuyuki
    Utsunomiya, Daisuke
    Oda, Seitaro
    Hirata, Kenichiro
    Yuki, Hideaki
    Kidoh, Masafumi
    Hatemura, Masahiro
    Yamashita, Yasuyuki
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2015, 31 (01): : 66 - 71
  • [4] Added value of a single-energy projection-based metal-artifact reduction algorithm for the computed tomography evaluation of oral cavity cancers
    Hirata, Kenichiro
    Utsunomiya, Daisuke
    Oda, Seitaro
    Kidoh, Masafumi
    Funama, Yoshinori
    Yuki, Hideaki
    Yoshida, Morikatsu
    Yamashita, Yasuyuki
    [J]. JAPANESE JOURNAL OF RADIOLOGY, 2015, 33 (10) : 650 - 656
  • [5] The effects of gantry tilt on breast dose and image noise in cardiac CT
    Hoppe, Michael E.
    Gandhi, Diksha
    Stevens, Grant M.
    Foley, W. Dennis
    Schmidt, Taly Gilat
    [J]. MEDICAL PHYSICS, 2013, 40 (12)
  • [6] Reduction of metallic coil artefacts in computed tomography body imaging: effects of a new single-energy metal artefact reduction algorithm
    Kidoh, Masafumi
    Utsunomiya, Daisuke
    Ikeda, Osamu
    Tamura, Yoshitaka
    Oda, Seitaro
    Funama, Yoshinori
    Yuki, Hideaki
    Nakaura, Takeshi
    Kawano, Takayuki
    Hirai, Toshinori
    Yamashita, Yasuyuki
    [J]. EUROPEAN RADIOLOGY, 2016, 26 (05) : 1378 - 1386
  • [7] CT dose reduction and dose management tools: Overview of available options
    McCollough, Cynthia H.
    Bruesewitz, Michael R.
    Kofler, James M., Jr.
    [J]. RADIOGRAPHICS, 2006, 26 (02) : 503 - U14
  • [8] Clinical evaluation of a newly developed method for avoiding artifacts caused by dental fillings on X-ray CT.
    Nakae Y.
    Sakamoto K.
    Minamoto T.
    Kamakura T.
    Ogata Y.
    Matsumoto M.
    Johkou T.
    [J]. Radiological Physics and Technology, 2008, 1 (1) : 115 - 122
  • [9] Lens Dose in Routine Head CT: Comparison of Different Optimization Methods With Anthropomorphic Phantoms
    Nikupaavo, Ulla
    Kaasalainen, Touko
    Reijonen, Vappu
    Ahonen, Sanna-Mari
    Kortesniemi, Mika
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2015, 204 (01) : 117 - 123
  • [10] Improved image quality in abdominal CT in patients who underwent treatment for hepatocellular carcinoma with small metal implants using a raw data-based metal artifact reduction algorithm
    Sofue, Keitaro
    Yoshikawa, Takeshi
    Ohno, Yoshiharu
    Negi, Noriyuki
    Inokawa, Hiroyasu
    Sugihara, Naoki
    Sugimura, Kazuro
    [J]. EUROPEAN RADIOLOGY, 2017, 27 (07) : 2978 - 2988