Development and evaluation of rapid and specific sdaA LAMP-LFD assay with Xpert MTB/RIF assay for diagnosis of tuberculosis

被引:10
作者
Joon, Deepali [1 ,2 ]
Nimesh, Manoj [2 ]
Gupta, Shraddha [3 ]
Kumar, Chanchal [3 ]
Varma-Basil, Mandira [3 ]
Saluja, Daman [1 ]
机构
[1] Univ Delhi, Dr BR Ambedkar Ctr Biomed Res, Delhi 110007, India
[2] Univ Delhi, Shri Guru Tegh Bahadur Khalsa Coll, Delhi 110007, India
[3] Univ Delhi, Vallabhbhai Patel Chest Inst, Dept Microbiol, Delhi 11007, India
关键词
Tuberculosis; Diagnosis; Loop mediated isothermal amplification; Mycobacterium tuberculosis; Lateral Flow Dipstick; MEDIATED ISOTHERMAL AMPLIFICATION; LATERAL FLOW DIPSTICK; SMEAR; UNIVERSAL; PCR;
D O I
10.1016/j.mimet.2019.03.002
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
There is need for rapid and cost-effective diagnostic test for tuberculosis. The present study was carried out to design a Loop-mediated isothermal amplification (LAMP) assay combined with lateral flow dipstick (LFD) as a point-of-care method for diagnosis of TB. LAMP assay targeting sdaA gene combined with LFD for sequence specific detection was standardized in user friendly and rapid format. It does not require sophisticated instruments and shows visual results instantly. The LAMP-LFD assay was validated using culture confirmed specimens. The assay was evaluated in a cross-sectional study using respiratory specimens collected from patients in Delhi, India and it showed high concordance with GeneXpert MTB/RIF assay. Lateral flow dipstick method has provided an excellent detection format with LAMP method. The LAMP-LFD assay showed high diagnostic accuracy in comparison to other methods and can be used as a point-of-care test in cost-effective manner.
引用
收藏
页码:161 / 166
页数:6
相关论文
共 34 条
[1]  
[Anonymous], 2016, USE LOOP MEDIATED IS
[2]  
[Anonymous], MICROBIOL SPECTR
[3]   Diagnosis of extrapulmonary tuberculosis by smear, culture, and PCR using universal sample processing technology [J].
Chakravorty, S ;
Sen, MK ;
Tyagi, JS .
JOURNAL OF CLINICAL MICROBIOLOGY, 2005, 43 (09) :4357-4362
[4]   Human pathogenic Cryptosporidium species bioanalytical detection method with single oocyst detection capability [J].
Connelly, John T. ;
Nugen, Sam R. ;
Borejsza-Wysocki, Wlodek ;
Durst, Richard A. ;
Montagna, Richard A. ;
Baeumner, Antje J. .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2008, 391 (02) :487-495
[5]   Comparison of the Efficacies of Loop-Mediated Isothermal Amplification, Fluorescence Smear Microscopy and Culture for the Diagnosis of Tuberculosis [J].
George, Geojith ;
Mony, Prem ;
Kenneth, John .
PLOS ONE, 2011, 6 (06)
[6]   Colorimetric detection of loop-mediated isothermal amplification reaction by using hydroxy naphthol blue [J].
Goto, Motoki ;
Honda, Eiichi ;
Ogura, Atsuo ;
Nomoto, Akio ;
Hanaki, Ken-Ichi .
BIOTECHNIQUES, 2009, 46 (03) :167-+
[7]   Direct detection of falciparum and non-falciparum malaria DNA from a drop of blood with high sensitivity by the dried-LAMP system [J].
Hayashida, Kyoko ;
Kajino, Kiichi ;
Simukoko, Humphrey ;
Simuunza, Martin ;
Ndebe, Joseph ;
Chota, Amos ;
Namangala, Boniface ;
Sugimoto, Chihiro .
PARASITES & VECTORS, 2017, 10 :1-9
[8]   Direct Blood Dry LAMP: A Rapid, Stable, and Easy Diagnostic Tool for Human African Trypanosomiasis [J].
Hayashida, Kyoko ;
Kajino, Kiichi ;
Hachaambwa, Lottie ;
Namangala, Boniface ;
Sugimoto, Chihiro .
PLOS NEGLECTED TROPICAL DISEASES, 2015, 9 (03)
[9]   The development of loop-mediated isothermal amplification combined with lateral flow dipstick for detection of Karlodinium veneficum [J].
Huang, Hai-Long ;
Zhu, Peng ;
Zhou, Cheng-Xu ;
He, Shan ;
Yan, Xiao-Jun .
HARMFUL ALGAE, 2017, 62 :20-29
[10]   Loop-mediated isothermal amplification as alternative to PCR for the diagnosis of extra-pulmonary tuberculosis [J].
Joon, D. ;
Nimesh, M. ;
Saluja, D. .
INTERNATIONAL JOURNAL OF TUBERCULOSIS AND LUNG DISEASE, 2015, 19 (08) :986-991