Role of free radicals in aseptic loosening of hip arthroplasty

被引:55
作者
Kinov, P
Leithner, A
Radl, R
Bodo, K
Khoschsorur, GA
Schauenstein, K
Windhager, R
机构
[1] Med Univ Graz, Dept Orthopaed Surg, A-8036 Graz, Austria
[2] Med Univ Sofia, Dept Orthopaed & Traumatol, Sofia 1527, Bulgaria
[3] Med Univ Graz, Inst Pathol, A-8036 Graz, Austria
[4] Med Univ Graz, Inst Clin Med, A-8036 Graz, Austria
[5] Med Univ Graz, Chem Lab Diagnost, A-8036 Graz, Austria
[6] Med Univ Graz, Inst Pathophysiol, A-8010 Graz, Austria
关键词
free radicals; aseptic loosening; oxidative stress; hip arthroplasty; periprosthetic fibrosis;
D O I
10.1002/jor.20013
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Fibrous pseudocapsule around hip implants is an invariable finding at revision operations and is believed to release inflammatory mediators that stimulate bone resorption. Reactive oxygen species have been proposed to be causative factors in various disorders with tissue fibrosis. We were interested in investigating whether aseptic loosening is connected with high oxidative stress, and in showing the underlying mechanism of periprosthetic fibrosis and its role in loosening. Levels of oxidative stress markers reduced (GSH) and oxidized (GSSG) gluthatione and malondialdehyde (MDA) were assayed in 28 loose hips and in 12 stable hips revised for high rate of wear and osteolysis. Collagen in the periprosthetic tissues was measured as hydroxyproline content. Osteolysis and polyethylene wear were graded. Increased oxidative stress measured by low GSH/GSSG ratio as well as by increased MDA level was established in patients compared to controls. Oxidative stress markers intercorrelated significantly. MDA and both GSH and GSSG levels correlated significantly with hydroxyproline level. Levels of GSSG and MDA were higher in hips with greater polyethylene wear. The results suggest that high oxidative stress may play a role in formation of a fibrous membrane observed at revision of loose hips. The fibrous pseudocapsule is probably related to high intraarticular pressure and expansion of the effective joint space. This study may elicit some aspects of the pathogenesis of aseptic hip loosening and aid in future investigations aiming at prevention of this complication. (c) 2005 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.
引用
收藏
页码:55 / 62
页数:8
相关论文
共 50 条
  • [31] How to Prevent Aseptic Loosening in Cementless Arthroplasty: A Review
    Apostu, Dragos
    Piciu, Doina
    Oltean-Dan, Daniel
    Cosma, Dan
    Lucaciu, Ondine
    Popa, Catalin
    Mester, Alexandru
    Benea, Horea
    APPLIED SCIENCES-BASEL, 2022, 12 (03):
  • [32] Bone mineral density and biochemical markers of bone turnover in aseptic loosening after total hip arthroplasty
    Wilkinson, JM
    Hamer, AJ
    Rogers, A
    Stockley, I
    Eastell, R
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2003, 21 (04) : 691 - 696
  • [33] Imaging study of aseptic loosening of the acetabular cup after cementless total hip arthroplasty: a retrospective study
    Aoyang He
    Yao Zhang
    Chunmiao Lu
    Lei Cao
    Jicun Liu
    Zhiwei Zhong
    BMC Musculoskeletal Disorders, 26 (1)
  • [34] Diagnostic accuracy of bone turnover markers as a screening tool for aseptic loosening after total hip arthroplasty
    Lawrence, Neil R.
    Jayasuriya, Raveen L.
    Gossiel, Fatma
    Wilkinson, J. Mark
    HIP INTERNATIONAL, 2015, 25 (06) : 525 - 530
  • [35] Role of inflammatory mediators and adhesion molecules in the pathogenesis of aseptic loosening in total hip arthroplasties
    Sabokbar, A
    Rushton, N
    JOURNAL OF ARTHROPLASTY, 1995, 10 (06) : 810 - 816
  • [36] Tourniquet-free minimally invasive total knee arthroplasty is associated with early aseptic loosening
    Kunes, Jennifer A.
    El-Othmani, Mouhanad M.
    Lavelle, Matthew
    Santos, Walkania M.
    Geller, Jeffrey A.
    Shah, Roshan P.
    KNEE, 2024, 46 : 19 - 26
  • [37] Relationship between the degree of osteolysis and cultures obtained by sonication of the prostheses in patients with aseptic loosening of a hip or knee arthroplasty
    Josep M. Sierra
    Sebastián García
    Juan C. Martínez-Pastor
    Xavier Tomás
    Xavier Gallart
    Jordi Vila
    Guillem Bori
    Francisco Maculé
    Josep Mensa
    Josep Riba
    Alex Soriano
    Archives of Orthopaedic and Trauma Surgery, 2011, 131
  • [38] Current methods of preventing aseptic loosening and improving osseointegration of titanium implants in cementless total hip arthroplasty: a review
    Apostu, Dragos
    Lucaciu, Ondine
    Berce, Cristian
    Lucaciu, Dan
    Cosma, Dan
    JOURNAL OF INTERNATIONAL MEDICAL RESEARCH, 2018, 46 (06) : 2104 - 2119
  • [39] Zirconia ageing is related to total hip arthroplasty aseptic loosening. A study of 45 retrieved zirconia heads
    Boyer, Bertrand
    Uribe, Juliana
    Launay, Manon
    Aurelle, Jean-Luc
    Philippot, Remi
    Geringer, Jean
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2024, 110 (08)
  • [40] High femoral offset as a risk factor for aseptic femoral component loosening in cementless primary total hip arthroplasty
    Lukas Jud
    Nico Rüedi
    Dimitris Dimitriou
    Armando Hoch
    Patrick O. Zingg
    International Orthopaedics, 2024, 48 : 1217 - 1224