Bridging Phenomenon in Contaminated Transformer Oil

被引:0
|
作者
Mahmud, Shekhar [1 ]
Chen, George [1 ]
Golosnoy, Igor O. [1 ]
Wilson, Gordon [2 ]
Jarman, Paul [2 ]
机构
[1] Univ Southampton, Southampton, Hants, England
[2] Natl Grid Warwick Technol, Warwick, England
关键词
bridging; cellulose fibre; conduction current;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The effect of cellulose particles contamination on transformer oil has been investigated. Different sizes and concentration levels of cellulose fibres were used to contaminate the transformer oil for the experiments. The conduction current was measured using electrodes of 10 mm diameter with a 10 mm gap and the optical microscopic images of bridge creation between the electrodes were also recorded. The bridge was thickened with increasing concentration level and the bridging time was shortened as the voltage increased. The conduction current increased with concentration level and voltage. Smaller size particles had stronger bond while creating the bridge and higher conduction current.
引用
收藏
页码:180 / 183
页数:4
相关论文
共 50 条
  • [21] A catalyzed method to remove polychlorinated biphenyls from contaminated transformer oil
    Maghami, Arash
    Gholipour-Zanjani, Nooshin
    Khorasheh, Farhad
    Arjmand, Mehdi
    ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2022, 29 (09) : 13253 - 13267
  • [22] Reviews on sulphur corrosion phenomenon of the oil-paper insulating system in mineral oil transformer
    Cong, Haoxi
    Pan, Hao
    Qian, Danyang
    Zhao, Haiyu
    Li, Qingmin
    HIGH VOLTAGE, 2021, 6 (02) : 193 - 209
  • [23] Bridging and discharge mechanisms of cellulose impurities in transformer oil under DC voltage
    Li, Yuan
    Zhou, Kai
    Yuan, Hao
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2020, 27 (03) : 1046 - 1049
  • [24] TESTING STATIC ELECTRIFICATION PHENOMENON IN A PRESSBOARD-TRANSFORMER OIL INSULATING SYSTEM
    SZUTA, J
    KEDZIA, J
    BRZOSTEK, E
    JOURNAL OF ELECTROSTATICS, 1982, 12 (APR) : 637 - 641
  • [25] Partial Discharge and Breakdown Characteristics of Moving Transformer Oil Contaminated by Metallic Particles
    Pan, Cheng
    Tang, Ju
    Tao, Xiantao
    Zhang, Yongze
    Ma, Shouxiao
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2018, 25 (05) : 1774 - 1784
  • [26] Variation of Discharge Characteristics With Temperature in Moving Transformer Oil Contaminated by Metallic Particles
    Pan, Cheng
    Tang, Ju
    Zhang, Yongze
    Luo, Xinyu
    Li, Xingxing
    IEEE ACCESS, 2018, 6 : 40050 - 40058
  • [27] Recycling of transformer oil contaminated by polychlorinated biphenyls (PCBs) using catalytic hydrodechlorination
    Choi, Hye-Min
    Veriansyah, Bambang
    Kim, Jaehoon
    Kim, Jae-Duck
    Lee, Youn-Woo
    JOURNAL OF ENVIRONMENTAL SCIENCE AND HEALTH PART A-TOXIC/HAZARDOUS SUBSTANCES & ENVIRONMENTAL ENGINEERING, 2009, 44 (05): : 494 - 501
  • [28] Breakdown Voltage of Transformer Oil Contaminated with Iron Particles at Pulsating DC Voltage
    Zhang, Jing
    Li, Jian
    Wang, Youyuan
    Li, Yuanlong
    Li, Xi
    ELECTRIC POWER COMPONENTS AND SYSTEMS, 2018, 46 (11-12) : 1321 - 1329
  • [29] The Emission Characteristics of Pollutants from Thermal Desorption of Soil Contaminated by Transformer Oil
    Jiang, Shixiong
    Weng, Sunxian
    ATMOSPHERE, 2022, 13 (04)
  • [30] REACTION REMOVAL OF POLYCHLORINATED-BIPHENYLS FROM TRANSFORMER OIL - TREATMENT OF CONTAMINATED OIL WITH POLY(ETHYLENE GLYCOL)/KOH
    BRUNELLE, DJ
    MENDIRATTA, AK
    SINGLETON, DA
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1985, 19 (08) : 740 - 746