A comparison of dual kV energy integrating and energy discriminating photon counting detectors for dual energy x-ray imaging

被引:2
|
作者
Wang, Adam S. [1 ]
Pelc, Norbert J. [1 ]
机构
[1] Stanford Univ, Dept Radiol, Stanford, CA 94305 USA
来源
MEDICAL IMAGING 2012: PHYSICS OF MEDICAL IMAGING | 2012年 / 8313卷
关键词
Dual energy; photon counting; pulse pileup; spectral tailing; material decomposition; CRLB; PULSE-HEIGHT SPECTRA; DOUBLE SUM PULSES; GENERALIZED METHOD; PILEUP; STATISTICS; TOMOGRAPHY; DISTORTION; QUALITY; CT;
D O I
10.1117/12.912030
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Dual energy imaging enables material decomposition and requires attenuation measurements with at least two different energies. Today's clinically available implementations use two separate exposures, at a low and high tube voltage (dual kV). Photon counting x-ray detectors (PCXDs) are an alternative technology that takes advantage of an x-ray source's broad spectrum by counting the number of transmitted photons at each energy from a single exposure. The richness of the information contained in these measurements can depend heavily on the detector's energy response, itself dependent on count rate. We compare the material decomposition precision of dual kV with energy integrating detectors to that of realistic PCXDs. We model the three primary effects that degrade PCXD performance: count rate limitations, energy resolution, and spectrum tailing. For example, the high flux rates required for clinical imaging pose a serious challenge for PCXDs. The Cramer-Rao Lower Bound is used to predict the best possible material decomposition variance as a function of these detector imperfections. For dual kV and photon counting, we determined the optimal kV, mAs, and filtration for a broad range of imaging tasks, subject to dose and tube power constraints. We found that a well-optimized dual kV protocol performs on par with the estimated performance of today's PCXDs. For dual kV protocols, it is helpful to increase the energy separation between the spectra by increasing the kV separation and adding filtration. For PCXDs, the detector's count rate capabilities must be increased and the spectrum tailing reduced for photon counting to become a competitive technology at the high intensities of clinical imaging.
引用
收藏
页数:13
相关论文
共 50 条
  • [31] Application of a dual energy X-ray imaging method on breast specimen
    Koukou, V.
    Martini, N.
    Fountos, G.
    Michail, C.
    Bakas, A.
    Oikonomou, G.
    Kandarakis, I.
    Nikiforidis, G.
    RESULTS IN PHYSICS, 2017, 7 : 1634 - 1636
  • [32] Dynamic material decomposition method for MeV dual-energy X-ray CT
    Zhao, Tiao
    Li, Liang
    Chen, Zhiqiang
    APPLIED RADIATION AND ISOTOPES, 2018, 140 : 55 - 62
  • [33] Effects of X-Ray Scatter in Quantitative Dual-Energy Imaging Using Dual-Layer Flat Panel Detectors
    Zhao, Chumin
    Liu, Stephen Z.
    Wang, Wenying
    Herbst, Magdalena
    Weber, Thomas
    Vogt, Sebastian
    Ritschl, Ludwig
    Kappler, Steffen
    Stayman, J. Webster
    Siewerdsen, Jeffrey H.
    Zbijewski, Wojciech
    MEDICAL IMAGING 2021: PHYSICS OF MEDICAL IMAGING, 2021, 11595
  • [34] Evaluation and comparison of a CdTe based photon counting detector with an energy integrating detector for X-ray phase sensitive imaging of breast cancer
    Ghani, Muhammad U.
    Omoumi, Farid H.
    Wu, Xizeng
    Fajardo, Laurie L.
    Zheng, Bin
    Liu, Hong
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2022, 30 (02) : 207 - 219
  • [35] Investigation of energy weighting using an energy discriminating photon counting detector for breast CT
    Kalluri, Kesava S.
    Mahd, Mufeed
    Glick, Stephen J.
    MEDICAL PHYSICS, 2013, 40 (08)
  • [36] Energy Dispersive Photon Counting Detectors for Breast Imaging
    Barber, William C.
    Wessel, Jan C.
    Malakhov, Nail
    Wawrzyniak, Gregor
    Hartsough, Neal E.
    Gandhi, Thulasi
    Nygard, Einar
    Iwanczyk, Jan S.
    MEDICAL APPLICATIONS OF RADIATION DETECTORS III, 2013, 8853
  • [37] A study of energy resolution in CPD indirect photon-counting X-ray imaging
    Nishihara, Toshiyuki
    Baba, Hiroyasu
    Kumagai, Oichi
    Izawa, Takashi
    Shinohara, Norimitsu
    MEDICAL IMAGING 2020: PHYSICS OF MEDICAL IMAGING, 2020, 11312
  • [38] Optimal energy threshold arrangement in photon-counting spectral x-ray imaging
    Roessl, Ewald
    Proksa, Roland
    2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 1950 - 1954
  • [39] Energy calibration of energy-resolved photon-counting pixel detectors using laboratory polychromatic x-ray beams
    Youn, Hanbean
    Han, Jong Chul
    Kam, Soohwa
    Yun, Seungman
    Kim, Ho Kyung
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2014, 760 : 79 - 85
  • [40] The Effects of Spectral Distortion on Multi-Energy X-ray Imaging Based on Photon Counting Detector
    Cho, Hyo-Min
    Choi, Yu-Na
    Lee, Seung-Wan
    Ryu, Hyun-Ju
    Lee, Young-Jin
    Kim, Hee-Joung
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 3001 - 3003