A comparison of dual kV energy integrating and energy discriminating photon counting detectors for dual energy x-ray imaging

被引:2
|
作者
Wang, Adam S. [1 ]
Pelc, Norbert J. [1 ]
机构
[1] Stanford Univ, Dept Radiol, Stanford, CA 94305 USA
来源
MEDICAL IMAGING 2012: PHYSICS OF MEDICAL IMAGING | 2012年 / 8313卷
关键词
Dual energy; photon counting; pulse pileup; spectral tailing; material decomposition; CRLB; PULSE-HEIGHT SPECTRA; DOUBLE SUM PULSES; GENERALIZED METHOD; PILEUP; STATISTICS; TOMOGRAPHY; DISTORTION; QUALITY; CT;
D O I
10.1117/12.912030
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Dual energy imaging enables material decomposition and requires attenuation measurements with at least two different energies. Today's clinically available implementations use two separate exposures, at a low and high tube voltage (dual kV). Photon counting x-ray detectors (PCXDs) are an alternative technology that takes advantage of an x-ray source's broad spectrum by counting the number of transmitted photons at each energy from a single exposure. The richness of the information contained in these measurements can depend heavily on the detector's energy response, itself dependent on count rate. We compare the material decomposition precision of dual kV with energy integrating detectors to that of realistic PCXDs. We model the three primary effects that degrade PCXD performance: count rate limitations, energy resolution, and spectrum tailing. For example, the high flux rates required for clinical imaging pose a serious challenge for PCXDs. The Cramer-Rao Lower Bound is used to predict the best possible material decomposition variance as a function of these detector imperfections. For dual kV and photon counting, we determined the optimal kV, mAs, and filtration for a broad range of imaging tasks, subject to dose and tube power constraints. We found that a well-optimized dual kV protocol performs on par with the estimated performance of today's PCXDs. For dual kV protocols, it is helpful to increase the energy separation between the spectra by increasing the kV separation and adding filtration. For PCXDs, the detector's count rate capabilities must be increased and the spectrum tailing reduced for photon counting to become a competitive technology at the high intensities of clinical imaging.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] Readout Architecture Based on a Novel Photon-Counting and Energy Integrating Processing for X-Ray Imaging
    Takagi, Katsuyuki
    Takagi, Toshiyuki
    Terao, Tsuyoshi
    Morii, Hisashi
    Koike, Akifumi
    Aoki, Toru
    IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES, 2021, 5 (04) : 501 - 507
  • [22] Dual-energy X-ray imaging: benefits and limits
    Rebuffel, V.
    Dinten, J-M
    INSIGHT, 2007, 49 (10) : 589 - 594
  • [23] Simultaneous dual-energy X-ray stereo imaging
    Mokso, Rajmund
    Oberta, Peter
    JOURNAL OF SYNCHROTRON RADIATION, 2015, 22 : 1078 - 1082
  • [24] Material separation in x-ray CT with energy resolved photon-counting detectors
    Wang, Xiaolan
    Meier, Dirk
    Taguchi, Katsuyuki
    Wagenaar, Douglas J.
    Patt, Bradley E.
    Frey, Eric C.
    MEDICAL PHYSICS, 2011, 38 (03) : 1534 - 1546
  • [25] The Effect of Photon Energy Weighting on X-ray Imaging Based on a Photon Counting Detector
    Choi, Yu-Na
    Lee, Seung-Wan
    Cho, Hyo-Min
    Ryu, Hyun-Ju
    Lee, Young-Jin
    Kim, Hee-Joung
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2011, 59 (05) : 3114 - 3119
  • [26] Characterization of energy response for photon-counting detectors using x-ray fluorescence
    Ding, Huanjun
    Cho, Hyo-Min
    Barber, William C.
    Iwanczyk, Jan S.
    Molloi, Sabee
    MEDICAL PHYSICS, 2014, 41 (12)
  • [27] Material Separation in X-ray CT with Energy Resolved Photon-Counting Detectors
    Wang, X.
    Meier, D.
    Taguchi, K.
    Wagenaar, D. J.
    Patt, B. E.
    Frey, E. C.
    MEDICAL IMAGING 2011: PHYSICS OF MEDICAL IMAGING, 2011, 7961
  • [28] Preliminary demonstration of flexible dual-energy x-ray phase-contrast imaging
    Wang, Shenghao
    Zan, Guibin
    Wang, Qiuping
    Liu, Shijie
    OPTICAL ENGINEERING, 2019, 58 (11)
  • [29] X-ray Synchrotron Dual Energy Imaging For Material Specific Study
    Singh, B.
    Agrawal, A. K.
    Kashyap, Y. S.
    Gadkari, S. C.
    61ST DAE-SOLID STATE PHYSICS SYMPOSIUM, 2017, 1832
  • [30] Signal to noise ratio of energy selective x-ray photon counting systems with pileup
    Alvarez, Robert E.
    MEDICAL PHYSICS, 2014, 41 (11)