Intra-abdominal Pressure Screening of Horses With Colic

被引:2
作者
de Paula, Vanessa B. [1 ]
Canola, Paulo A. [2 ]
Rivera, Gabriela G. [1 ]
Bonacin, Yuri S. [1 ]
Del Rio, Lara A. [3 ]
Canola, Julio C. [2 ]
Ferraudo, Antonio S. [4 ]
机构
[1] Sao Paulo State Univ Unesp, Sch Agr & Veterinarian Sci, Jaboticabal, SP, Brazil
[2] Sao Paulo State Univ Unesp, Sch Agr & Veterinarian Sci, Dept Vet Med & Surg, Via Acesso Prof Paulo Donato Castellane S-N, BR-14884900 Jaboticabal, SP, Brazil
[3] Crispim & Stevanato Vet Hosp, Mirassolandia, SP, Brazil
[4] Sao Paulo State Univ Unesp, Sch Agr & Veterinarian Sci, Dept Math Sci, Jaboticabal, SP, Brazil
关键词
ABDOMINAL COMPARTMENT SYNDROME; INTERNATIONAL-CONFERENCE; PERFUSION PRESSURES; BODY POSITION; HYPERTENSION; EXPERTS;
D O I
10.1016/j.jevs.2020.102998
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
The objective of this study was to evaluate changes in intra-abdominal pressure (IAP) in horses with colic by associating the underlying etiologies with directly acquired IAP values and survival rate. This is a 2-year cohort study (2014–2016). Horses with clinical signs of colic were admitted to the veterinary teaching hospital during the period 2014–2016. Twenty-eight horses, of different breeds, males (stallions and geldings) and females, aged between 2 and 20 years, and weighing from 300 to 450 kg presenting with clinical signs of colic, were included in the study. IAP was directly acquired at the right flank (standing under sedation) and at the linea alba (supine position under general anesthesia). Twenty IAP measurements were recorded at end expiration for each recording site. IAP values >0.0 mmHg, obtained at the upper right flank in the standing position, were associated with surgical treatment (P < .05). In these cases, signs of colic were associated with strangulated obstructions of the large colon, and a greater likelihood of death as a result of colic (P < .001). Intra-abdominal pressure varied considerably in horses with colic, even for the same underlying etiologies. Horses with colic related to strangulating obstructions of the large intestine had IAP >.0 mmHg, at the upper right flank. These horses were also considerably more likely to require surgical intervention (P < .05) and death/euthanasia was more likely in this group of horses (P < .001). © 2020 Elsevier Inc.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] Can femoral venous pressure be used as an estimate for standard vesical intra-abdominal pressure measurement?
    Howard, A. E.
    Regli, A.
    Litton, E.
    Malbrain, M. M.
    Palermo, A-M.
    De Keulenaer, B. L.
    ANAESTHESIA AND INTENSIVE CARE, 2016, 44 (06) : 704 - 711
  • [32] Intra-abdominal pressure alterations after large pancreatic pseudocyst transcutaneous drainage
    Papavramidis, Theodossis S.
    Duros, Vassilis
    Michalopoulos, Antonis
    Papadopoulos, Vassilis N.
    Paramythiotis, Daniel
    Harlaftis, Nick
    BMC GASTROENTEROLOGY, 2009, 9
  • [33] Intra-abdominal hypertension in two adult horses
    Brosnahan, Margaret M.
    Holbrook, Todd C.
    Gilliam, Lyndi L.
    Ritchey, Jerry W.
    Confer, Anthony W.
    JOURNAL OF VETERINARY EMERGENCY AND CRITICAL CARE, 2009, 19 (02) : 174 - 180
  • [34] Intra-abdominal pressure as a predictor of acute kidney injury in postoperative abdominal surgery
    dos Santos Demarchi, Ana Carolina
    Puato de Almeida, Cibele Tais
    Ponce, Daniela
    Novelli e Castro, Meire Cristina
    Danaga, Aline Roberta
    Yamaguti, Fabio Akio
    Vital, Danielle
    Gut, Ana Lucia
    dos Anjos Ferreira, Ana Lucia
    Freschi, Larissa
    Oliveira, Juliana
    Teixeira, Ubirajara Aparecido
    Christovan, Jose Carlos
    Grejo, Juliana Rigoto
    Martin, Luis Cuadrado
    RENAL FAILURE, 2014, 36 (04) : 557 - 561
  • [35] Alternative Intrabladder Manometry Technique for the Indirect Measurement of Intra-abdominal Pressure in Horses
    Canola, Paulo Alescio
    Perotta, Joao Henrique
    Martins Dias, Deborah Penteado
    Canola, Julio Carlos
    Johnson, Philip J.
    Araujo Valadao, Carlos Augusto
    JOURNAL OF EQUINE VETERINARY SCIENCE, 2012, 32 (03) : 183 - 189
  • [36] Influence of volume increase on intra-abdominal pressure
    Schachtrupp, A.
    ANAESTHESIST, 2009, 58 (05): : 532 - 536
  • [37] Measurement of intra-abdominal pressure in dogs and cats
    Smith, Shelley E.
    Sande, Allison A.
    JOURNAL OF VETERINARY EMERGENCY AND CRITICAL CARE, 2012, 22 (05) : 530 - 544
  • [38] Intra-abdominal Pressure Measurement - Step by Step
    Kuhn, Anja
    Fuchs, Christian
    Hahnenkamp, Klaus
    DEUTSCHE MEDIZINISCHE WOCHENSCHRIFT, 2021, 146 (18) : 1211 - 1217
  • [39] Intra-Abdominal Pressure Measurements in Neurocritical Patients
    Xu, Xuxu
    He, Zhenghui
    Shan, Yingchi
    Mao, Qing
    Feng, Junfeng
    Gao, Guoyi
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2021, (171):
  • [40] Assessment of Intra-Abdominal Pressure with a Novel Continuous Bladder Pressure Monitor-A Clinical Validation Study
    Iacubovici, Liat
    Karol, Dana
    Baar, Yuval
    Beri, Avi
    Herzberg, Haim
    Zarour, Shiri
    Goren, Or
    Cohen, Barak
    LIFE-BASEL, 2023, 13 (02):