The reliability of glomerular filtration rate measured from plasma clearance: a multi-centre study of 1,878 healthy potential renal transplant donors

被引:14
作者
Peters, A. Michael [1 ]
Howard, Bethany [2 ]
Neilly, Mark D. J. [15 ]
Seshadri, Nagabhushan [3 ]
Sobnack, Ravin [4 ]
Hooker, Claire A. [5 ]
Irwin, Andrew [6 ]
Snelling, Hayley [1 ]
Gruning, Thomas [7 ]
Perry, Laura [10 ]
Patel, Neva H. [14 ]
Lawson, Richard S. [11 ]
Shabo, Gregory [8 ]
Williams, Nigel [12 ]
Dave, Surendra [9 ]
Barnfield, Mark C. [13 ]
机构
[1] Royal Sussex Cty Hosp, Dept Nucl Med, Brighton BN2 5BE, E Sussex, England
[2] Addenbrookes Hosp, Dept Nucl Med, Cambridge CB2 2QQ, England
[3] Royal Liverpool Univ Hosp, Dept Nucl Med, Liverpool, Merseyside, England
[4] St Bartholomews Hosp, Dept Nucl Med, London, England
[5] Kings Coll Hosp London, Dept Nucl Med, London, England
[6] Univ London St Georges Hosp, Dept Nucl Med, London, England
[7] Derriford Hosp, Dept Nucl Med, Plymouth PL6 8DH, Devon, England
[8] Kent & Canterbury Hosp, Dept Nucl Med, Canterbury, Kent, England
[9] St Marys Hosp, Dept Nucl Med, London, England
[10] Royal Free Hosp, Dept Med Phys, London NW3 2QG, England
[11] Manchester Royal Infirm, Dept Med Phys, Manchester M13 9WL, Lancs, England
[12] Univ Hosp, Dept Med Phys, Coventry, W Midlands, England
[13] St James Univ Hosp, Dept Med Phys, Leeds, W Yorkshire, England
[14] Univ London Imperial Coll Sci Technol & Med, Radiol Sci Unit, Dept Med Phys, London, England
[15] Glasgow Royal Infirm, Univ Med Unit, Dept Med Phys, Glasgow G4 0SF, Lanark, Scotland
关键词
Glomerular filtration rate; Extracellular fluid volume; Renal transplant donors; EXTRACELLULAR FLUID VOLUME; SINGLE INJECTION; INULIN; 51CR-EDTA;
D O I
10.1007/s00259-011-2024-5
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The objective of the study was to undertake a clinical audit of departmental performance in the measurement of glomerular filtration rate (GFR) using the coefficient of variation (CV) of extracellular fluid volume (ECFV) as the benchmark. ECFV is held within narrow limits in healthy subjects, narrower than GFR, and should therefore have a low CV. Fifteen departments participated in this retrospective study of healthy renal transplant donors. Data were analysed separately for men (n ranged from 28 to 115 per centre; total = 819) and women (n = 28-146; 1,059). All centres used the slope-intercept method with blood sample numbers ranging from two to five. Subjects did not fast prior to GFR measurement. GFR was scaled to body surface area (BSA) and corrected for the single compartment assumption. GFR scaled to ECFV was calculated as the terminal slope rate constant and corrected for the single compartment assumption. ECFV/BSA was calculated as the ratio of GFR/BSA to GFR/ECFV. The departmental CVs of ECFV/BSA and GFR/BSA ranged from 8.3 to 25.8% and 12.8 to 21.9%, respectively, in men, and from 9.6 to 21.1% and 14.8 to 23.7%, respectively, in women. Both CVs correlated strongly between men and women from the same centre, suggesting department-specific systematic errors. GFR/BSA was higher in men in 14 of 15 centres, whereas GFR/ECFV was higher in women in 14 of 15 centres. Both correlated strongly between men and women, suggesting regional variation in GFR. The CV of ECFV/BSA in normal subjects is a useful indicator of the technical robustness with which GFR is measured and, in this study, indicated a wide variation in departmental performance.
引用
收藏
页码:715 / 722
页数:8
相关论文
共 20 条