Study of bond Elut® Plexa™ PCX cation exchange resin in flow injection column preconcentration system for metal determination by flame atomic absorption spectrometry

被引:20
作者
Anthemidis, Aristidis N. [1 ]
Xidia, Sofia [1 ]
Giakisikli, Georgia [1 ]
机构
[1] Aristotle Univ Thessaloniki, Dept Chem, Analyt Chem Lab, Fac Sci, GR-54006 Thessaloniki, Greece
关键词
Bond Elut (R) Plexa (TM) PCX; Flow injection; Column preconcentration; Metal determination; Atomic absorption spectrometry; SOLID-PHASE EXTRACTION; ONLINE PRECONCENTRATION; WATER SAMPLES; PACKED-COLUMN; BIOLOGICAL SAMPLES; SORBENT MATERIAL; MICRO-CARTRIDGE; TRACE-ELEMENTS; COPPER; LEAD;
D O I
10.1016/j.talanta.2012.04.014
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A simple and sensitive on-line solid-phase extraction methodology for preconcentration and determination of trace amounts of Cd(II), Pd(II) and Cu(II) in natural water samples has been developed using the strong cation exchange capability of Bond Elut (R) Plexa (TM) PCX polymer resin. Plexa PCX is a mixed-mode sorbent, commercially available in a cartridge format and as far as we know, there is no application into the field of metal determination. The analytes were retained on the resin, eluted with 1 mol L-1 hydrochloric acid and subsequently directed to FAAS for quantification. The influence of chemical and flow variables which affect the performance of the system have been studied, providing the appropriate conditions for the analysis of real samples. For preconcentration time of 90 s, an enrichment factor of 90, 95 and 95 and a detection limit (3s) of 0.1, 1.8 and 0.5 mu g L-1 for Cd(II), Pb(II) and Cu(II), respectively were obtained along with a sampling frequency of 30 h(-1). The accuracy of the proposed method was evaluated by analyzing certified reference materials. This procedure was successfully applied for metal determination in environmental and biological samples. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:181 / 186
页数:6
相关论文
共 37 条
[1]   Removal of some heavy metal cations by synthetic resin purolite C100 [J].
Abo-Farha, S. A. ;
Abdel-Aal, A. Y. ;
Ashour, I. A. ;
Garamon, S. E. .
JOURNAL OF HAZARDOUS MATERIALS, 2009, 169 (1-3) :190-194
[2]   On-line preconcentration and determination of copper, lead and chromium(VI) using unloaded polyurethane foam packed column by flame atomic absorption spectrometry in natural waters and biological samples [J].
Anthemidis, AN ;
Zachariadis, GA ;
Stratis, JA .
TALANTA, 2002, 58 (05) :831-840
[3]   On-line solid phase extraction system using PTFE packed column for the flame atomic absorption spectrometric determination of copper in water samples [J].
Anthemidis, AN ;
Zachariadis, GA ;
Stratis, JA .
TALANTA, 2001, 54 (05) :935-942
[4]   Determination of chromium(VI) and lead in water samples by on-line sorption preconcentration coupled with flame atomic absorption spectrometry using a PCTFE-beads packed column [J].
Anthemidis, Aristidis N. ;
Koussoroplis, Salome-Juliette V. .
TALANTA, 2007, 71 (04) :1728-1733
[5]   Evaluation of polychlorotrifluoroethylene as sorbent material for on-line solid phase extraction systems: Determination of copper and lead by flame atomic absorption spectrometry in water samples [J].
Anthemidis, Aristidis N. ;
Ioannou, Kallirroy-Ioanna G. .
ANALYTICA CHIMICA ACTA, 2006, 575 (01) :126-132
[6]   The HyperSep SCX micro-cartridge for on-line flow injection inductively coupled plasma atomic emission spectrometric determination of trace elements in biological and environmental samples [J].
Anthemidis, Aristidis N. ;
Giakisikli, Georgia ;
Zachariadis, George A. .
ANALYTICAL METHODS, 2011, 3 (09) :2108-2114
[7]   Flow injection online solid phase extraction system using Oasis-HLB™ micro-cartridge for chromium(VI) and copper determination by flame atomic absorption spectrometry [J].
Anthemidis, Aristidis N. ;
Maloumidou, Thalia .
ANALYTICAL METHODS, 2011, 3 (06) :1392-1398
[8]   On-line sorptive preconcentration platform incorporating a readily exchangeable Oasis HLB extraction micro-cartridge for trace cadmium and lead determination by flow injection-flame atomic absorption spectrometry [J].
Anthemidis, Aristidis N. ;
Giakisikli, Georgia ;
Xidia, Sofia ;
Miro, Manuel .
MICROCHEMICAL JOURNAL, 2011, 98 (01) :66-71
[9]   Poly(etheretherketone)-turnings a novel sorbent material for lead determination by flow injection flame atomic absorption spectrometry and factorial design optimization [J].
Anthemidis, Aristidis N. ;
Adam, Ibrahim S. I. ;
Zachariadis, George A. .
TALANTA, 2010, 81 (03) :996-1002
[10]   Chromatographic separations and recovery of lead ions from a synthetic binary mixtures of some heavy metal using cation exchange resin [J].
Badawy, N. A. ;
El-Bayaa, A. A. ;
Abdel-Aal, A. Y. ;
Garamon, S. E. .
JOURNAL OF HAZARDOUS MATERIALS, 2009, 166 (2-3) :1266-1271