Configuring a fuel cell based residential combined heat and power system

被引:5
|
作者
Ahmed, Shabbir [1 ]
Papadias, Dionissios D. [1 ]
Ahluwalia, Rajesh K. [1 ]
机构
[1] Argonne Natl Lab, Lemont, IL 60439 USA
关键词
Fuel cell; Polymer electrolyte; Heat and power; CHP; Systems analysis; CHP; HYDROGEN; PEMFC;
D O I
10.1016/j.jpowsour.2013.01.034
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The design and performance of a fuel cell based residential combined heat and power (CHP) system operating on natural gas has been analyzed. The natural gas is first converted to a hydrogen-rich reformate in a steam reformer based fuel processor, and the hydrogen is then electrochemically oxidized in a low temperature polymer electrolyte fuel cell to generate electric power. The heat generated in the fuel cell and the available heat in the exhaust gas is recovered to meet residential needs for hot water and space heating. Two fuel processor configurations have been studied. One of the configurations was explored to quantify the effects of design and operating parameters, which include pressure, temperature, and steam-to-carbon ratio in the fuel processor, and fuel utilization in the fuel cell. The second configuration applied the lessons from the study of the first configuration to increase the CHP efficiency. Results from the two configurations allow a quantitative comparison of the design alternatives. The analyses showed that these systems can operate at electrical efficiencies of similar to 46% and combined heat and power efficiencies of similar to 90%. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:884 / 894
页数:11
相关论文
共 50 条
  • [1] Current status of fuel cell based combined heat and power systems for residential sector
    Ellamla, Harikishan R.
    Staffell, Iain
    Bujlo, Piotr
    Pollet, Bruno G.
    Pasupathi, Sivakumar
    JOURNAL OF POWER SOURCES, 2015, 293 : 312 - 328
  • [2] Green hydrogen energy source for a residential fuel cell micro-combined heat and power
    Elkhatib, Rafik
    Kaoutari, Taoufiq
    Louahlia, Hasna
    APPLIED THERMAL ENGINEERING, 2024, 248
  • [3] Improved performance of a residential combined heat and power system by integrating compact fuel processor and proton exchange membrane fuel cell
    Zhang, Jing
    Li, Duo
    Zhong, Hexiang
    Li, Jinxiao
    Chen, Shuhua
    Song, Rensheng
    Jin, Wenyao
    Pan, Liwei
    ENERGY SCIENCE & ENGINEERING, 2022, 10 (08) : 2732 - 2740
  • [4] An energy management strategy for supplying combined heat and power by the fuel cell thermoelectric hybrid system
    Kwan, Trevor Hocksun
    Shen, Yongting
    Yao, Qinghe
    APPLIED ENERGY, 2019, 251
  • [5] Evaluation of energy, environmental, and economic characteristics of fuel cell combined heat and power systems for residential applications
    Gunes, MB
    Ellis, MW
    JOURNAL OF ENERGY RESOURCES TECHNOLOGY-TRANSACTIONS OF THE ASME, 2003, 125 (03): : 208 - 220
  • [6] Evaluation of system configurations for solid oxide fuel cell-based micro-combined heat and power generators in residential applications
    Braun, R. J.
    Klein, S. A.
    Reindl, D. T.
    JOURNAL OF POWER SOURCES, 2006, 158 (02) : 1290 - 1305
  • [7] Analysis of a 1 kW residential combined heating and power system based on solid oxide fuel cell
    Xu, Han
    Dang, Zheng
    Bai, Bo-Feng
    APPLIED THERMAL ENGINEERING, 2013, 50 (01) : 1101 - 1110
  • [8] Part two:: Control of a novel HTPEM-based micro combined heat and power fuel cell system
    Korsgaard, Anders R.
    Nielsen, Mads P.
    Kaer, Soren K.
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2008, 33 (07) : 1921 - 1931
  • [9] Fuel consumption analysis of a residential cogeneration system using a solid oxide fuel cell with regulation of heat to power ratio
    Lamas, J.
    Shimizu, H.
    Matsumura, E.
    Senda, J.
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2013, 38 (36) : 16338 - 16343
  • [10] Energy and exergy analysis of a fuel cell based micro combined heat and power cogeneration system
    Xie, Donglai
    Wang, Ziliang
    Jin, Lian
    Zhang, Yajun
    ENERGY AND BUILDINGS, 2012, 50 : 266 - 272